Use of a non-invasive electrocardiographic mapping system may aid in rapid diagnosis of atrial or ventricular arrhythmias or the detection of ventricular dyssynchrony. The aim of the present study was to validate the mapping accuracy of a novel non-invasive epi- and endocardial electrophysiology system (NEEES). Patients underwent pre-procedural computed tomography or magnetic resonance imaging of the heart and torso. Radiographic data were merged with the data obtained from the NEEES during pacing from implanted pacemaker leads or pacing from endocardial sites using an electroanatomical mapping system (CARTO 3, Biosense Webster). The earliest activation as denoted on the NEEES three-dimensional heart model was compared with the true anatomic location of the tip of the pacemaker lead or the annotated pacing site on the CARTO 3 map. Twenty-nine patients [mean age: 62 ± 11 years, 6/29 (11%) female, 21/29 (72%) with ischaemic cardiomyopathy] were enrolled into the pacemaker verification group. The mean distance from the non-invasively predicted pacing site to the anatomic reference site was 10.8 ± 5.4 mm for the right atrium, 7.7 ± 5.8 mm for the right ventricle, and 7.9 ± 5.7 mm for the left ventricle activated via the coronary sinus lead. Five patients [mean age 65 ± 4 years, 2 (33%) females] underwent CARTO 3 verification study. The mean distance between non-invasively reconstructed pacing site and the reference pacing site was 7.4 ± 2.7 mm for the right atrium, 6.9 ± 2.3 mm for the left atrium, 6.5 ± 2.1 mm for the right ventricle, and 6.4 ± 2.2 for the left ventricle, respectively. The novel NEEES was able to correctly identify the site of pacing from various endo- and epicardial sites with high accuracy.
Although model-based solution strategies for the ECGI were reported to deliver promising clinical results, they strongly rely on some a priori assumptions, which do not hold true for many pathological cases. The fastest route algorithm (FRA) is a well-established method for noninvasive imaging of ectopic activities. It generates test activation sequences on the heart and compares the corresponding test body surface potential maps (BSPMs) to the measured ones. The test excitation propagation patterns are constructed under the assumption of a global conduction velocity in the heart, which is violated in the cardiac resynchronization (CRT) patients suffering from conduction disturbances. In the present work, we propose to apply dynamic time warping (DTW) to the test and measured ECGs before measuring their similarity. The warping step is a non-linear pattern matching that compensates for local delays in the temporal sequences, thus accounting for the inhomogeneous excitation propagation, while aligning them in an optimal way with respect to a distance function. To evaluate benefits of the temporal warping for FRA-based BSPMs, we considered three scenarios. In the first setting, a simplified simulation example was constructed to illustrate the temporal warping and display the resulting distance map. Then, we applied the proposed method to eight BSPMs produced by realistic ectopic activation sequences and compared its performance to FRA. Finally, we assessed localization accuracy of both techniques in ten CRT patients. For each patient, we noninvasively imaged two paced ECGs: from left and right ventricular implanted leads. In all scenarios, FRA-DTW outperformed FRA in terms of LEs. For the clinical cases, the median (25–75% range) distance errors were reduced from 16 (8–23)mm to 5 (2–10)mm for all pacings, from 15 (11–25)mm to 8 (3–13)mm in the left, and from 19 (6–23)mm to 4 (2–8)mm in the right ventricle, respectively. The obtained results suggest the ability of temporal ECG warping to compensate for an inhomogeneous conduction profile, while retaining computational efficiency intrinsic to FRA.
Aim. To analyze 20 electrocardiographic (ECG) signs of left bundle branch block (LBBB) before and after septal myectomy in patients with hypertrophic cardio myopathy (HCM) and develop a criterion for proximal LBBB based on the selected signs.Material and methods. This retrospective non-randomized study included 50 patients with obstructive HCM who underwent septal myectomy. There were following inclusion criteria: QRS width <120 ms before surgery, transaortic access during septal myectomy, and QRS width ≥120 ms in the early postoperative period. For each patient, ECGs were analyzed before septal myectomy and in the first week after surgery. At the same time, 20 ECG signs proposed earlier in the LBBB criteria were independently assessed.Results. Exsection of a small myocardial area of the basal interventricular septal parts, weighing an average of 4,9±2 grams, led to a significant increase in the QRS width (by 61±14,6 ms) and the prevalence of almost all ECG signs of LBBB. In 100% of cases (n=50), the following signs demonstrated significant dynamics after surgery: (1) midQRS notching or slurring in ≥2 contiguous leads (I, aVL, V1-V2, V5-V6); (2) absence of q wave in V5-V6 and (3) discordant T wave in at least two leads (I, aVL, V5, V6). Based on the design of the study, (4) QRS width ≥120 ms was additionally included. These ECG characteristics were combined into a new criterion for proximal LBBBConclusion. A new criterion for proximal LBBB was developed using the pathophysiological model of iatrogenic conduction block of left bundle branch. Further estimation of this criterion on a set of candidates for CRT with heterogeneous level of LBBB is necessary.