Traian-Nicu Toader

Dr. Traian-Nicu Toader

Structures, Technical University of Cluj-Napoca, Cluj-Napoca, Cluj, Romania
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
TTTraian-Nicu Toader
Traian-Nicu Toader
CMCalin Mircea
Calin Mircea
Alina Maria TrutaAlina Maria Truta
Alina Maria Truta
HCHoria Constantinescu
Horia Constantinescu
This article contains the results of identifying the potential of coniferous trees to act as bioinspiration for the structural design of columns in single-story warehouses subjected to high wind velocity and severe seismic action. This study starts by analyzing the biomechanics of coniferous trees, continues with an abstraction of the relevant features, and ends with the transfer of a design methodology for long reinforced and prestressed concrete columns. To verify the applicability and validity of the mathematical relationships extracted from the bibliographic study to characterize the biomechanics of coniferous trees, a study site is conducted for Norway spruce trees felled by the wind in the Bilbor area. The design methodology for long reinforced and prestressed concrete columns bioinspired by the Norway spruce trees is experimentally validated using two case studies. The first case study deals with the effect of centric prestressing on long concrete columns, and the second on the influence of the walnut shell powder on the adhesion of the reinforcement in concrete. The case studies presented aim to transfer some characteristics from trees to reinforced concrete to improve the performance of long columns under horizontal forces. The results obtained indicate a good approximation of the trees’ structural behavior for this site and for ones investigated by other researchers in different forests.

1 July 2021 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
TTTraian-Nicu Toader
Traian-Nicu Toader
ZKZ Kiss
Z Kiss
SȚS-G Țere
S-G Țere
APA Puskás
A Puskás
This article contains practical information on the design and dimensioning of prestressed concrete solid flat slabs using unbonded post-tensioned tendons, in accordance with the European standard EN 1992-1-1 and German standard DIN 1045-1. The calculation method and the mathematical equations necessary for the dimensioning of the non-adherent unguided tendons are given. The paper presents a case study where a slab floor is dimensioned for deflection using prestressing only in the column strips. The deflection of the slab is calculated using equivalent loads (unguided tendon), a mixt tendon profile with 4th degree curve segments (unguided tendon) and parabolic tendon profile with 2nd degree curve segments (guided tendon-classical solution).

30 October 2024 in Buildings
Verified
Journal Article
Open access
PDF file
HCHoria Constantinescu
Horia Constantinescu
TTTraian-Nicu Toader
Traian-Nicu Toader
The connection between a prefabricated reinforced concrete column and a pocket foundation is a case treated from a general perspective in the European Standard named EN 1992-1-1 (EC2), and when the structural engineer deals with the dimensioning or verification of the connection, he must tackle several unknowns. The present work aims to fill in the missing information by presenting detailed calculation models based on the strut-and-tie method for four widely used pocket foundations: a pedestal pocket foundation with smooth, rough or keyed internal walls and a pad foundation with a pocket possessing keyed internal walls. In establishing the strut-and-tie models and writing the equation for the internal forces, we consider several standards (EC2, NBR 9062 and DIN 1045-1), good practices (from Austria, England, Germany and Romania) and numerous experimental and numerical investigations. Additionally, detailed design prescriptions applicable to seismic areas are given. This manuscript covers a wide range of design and technology aspects necessary for designing and building columns connected with pocket foundations, information for which is shown only in fragmented form or partially in other publications. Afterward, as a case study, a pocket foundation is designed in all four variations, with the structural design particularities, similitudes and differences being pointed out. Finally, to conclude, we mention the advantages and disadvantages of pocket foundations with respect to the type of internal wall surface used. Quantifiable data based on the case study undertaken are available.

1 May 2022 in Journal of Applied Engineering Sciences
Verified
Journal Article
Open access
PDF file
BKB. Kovacs
B. Kovacs
TTTraian-Nicu Toader
Traian-Nicu Toader
This article aims to describe an automatic calculation algorithm developed for the analysis of reinforced concrete and / or prestressed concrete cross sections. The sectional analysis consists in the generation of two characteristic curves: the bending moment - curvature ( M-1/r ) and the axial force - bending moment ( N-M ), the calculation approach and the implementation of the algorithm being briefly described by the mathematical equations used. To verify the calculation algorithm, the results were compared with those obtained from experimental tests in the laboratory but also with numerical simulations using commercial computational software based on the finite element method (FEM). The algorithm was written in the MATLAB programming language. The results obtained with the developed algorithm show conservative results when compared to the experimental ones. Moreover, the bending moment resistance for prestressed concrete columns using bonded tendons is better estimated with at least 10% when compared with the one obtained with a fiber based cross section nonlinear analyses.

27 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
HCHoria Constantinescu
Horia Constantinescu
TTTraian-Nicu Toader
Traian-Nicu Toader
The connection between a prefabricated reinforced concrete column and a pocket foundation is a case treated from a general perspective in the European Standard named EN 1992-1-1, and when the structural engineer deals with the dimensioning or verification of the connection, he tackles several unknowns. The present work aims to fill in the missing information by presenting detailed calculation models based on the strut-and-tie method for 4 of the widely used pocket foundations: pedestal pocket foundation with smooth, rough or keyed internal walls, and pad foundation with pocket possessing keyed internal walls. Additionally, detailed design prescriptions applicable to seismic areas are given. Afterwards, as a case study, a pocket foundation is designed in all 4 variations, having the structural design particularities, similitudes and differences pointed out. Finally, to conclude the advantages and disadvantages are mentioned for pocket foundations in respect to the type of internal wall surface used. Quantifiable data based on the case study undertaken is available.

1 May 2025 in Journal of Applied Engineering Sciences
Verified
Journal Article
Open access
PDF file
TTTraian-Nicu Toader
Traian-Nicu Toader
In this article, the topic of reinforced and prestressed concrete (RC and PC) flat slabs deflection is addressed, focusing on a new method that facilitates a simplified calculation. The proposed calculation method is based on the strip method, and for its validation the results from a parametric case study are compared with those obtained by other calculation methods suitable for estimating the deflection of flat slabs. To be more practical, the proposed method is transformed into a coefficient method (closed form formula) and allows the calculation of the deflection also for external, corner and isolated slab panels, unlike the existing closed form formula approaches which are only available either for the internal or corner slab panels. In addition, the difference between the deflection values obtained considering the uncracked versus cracked concrete section, respectively between the instantaneous (short -term) deflection and the long-term deflection values of the RC and PC slabs is addressed.