For more than ten years the CEA has been using gamma imaging systems for radiological characterization purposes during decommissioning operations. This technology is very effective for detecting high-energy gamma emitters, but less so for characterizing actinides, which are mainly alpha emitters. In order to provide a full range of decommissioning tools, the gamma-cameras were supplemented by another imaging system capable of generating images directly from alpha emissions. This paper describes the initial laboratory and field test results obtained with a prototype camera capable of displaying alpha radioactivity. The system is based on the detection of ultraviolet radiation emitted by nitrogen when irradiated by alpha particles. The alpha contamination is localized by superimposing it on a visible-light image. All measurements must be carried out in complete darkness. Laboratory tests showed that the system is capable of detecting point sources and extended sources at levels as low as 430 Bqmiddotcm-2. Profile measurements of point sources revealed a scintillation bubble with dimensions corresponding to the range of alpha particles in air. The device is also capable of detecting the phenomenon through translucent materials such as glove box panels. The camera has been implemented for in situ examination of various fuel cycle facilities, and under these conditions has revealed alpha contamination without any breach of containment through several millimeters of plexiglas
16 August 2004 in IEEE Transactions on Nuclear Science
In the 1990s, CEA has developed a very compact operational gamma camera, CARTOGAM, capable of mapping the surrounding radioactivity and representing it superimposed onto a visible-light image. Since then, the camera has been successfully industrialized and commercialized. In the same time, the Kurchatov Institute has developed a coded-aperture gamma camera. Both teams have joined their efforts to develop a compact coded-aperture gamma camera. This paper presents the first results obtained with a coded mask adapted to the existing CARTOGAM camera. Simulations have been carried out to design small-sized coded masks for high-energy gamma imaging (/sup 137/Cs or /sup 60/Co). Innovative tungsten-alloy masks have been achieved that lead to the following results: a significant increase in the sensitivity (up to 10 times), an improved angular resolution (2/spl deg/ to 3/spl deg/) and a large field of view (about 30/spl deg/). The laboratory results of /sup 137/Cs and /sup 60/Co imaging, including shadowgrams and reconstructed images for point sources, are presented.
1 December 2012 in Optics and Lasers in Engineering