Man-Zhou Zhang

Dr. Man-Zhou Zhang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2023 in Nuclear Science and Techniques
Verified
Journal Article
Open access
PDF file
MZMan-Zhou Zhang
Man-Zhou Zhang
DLDe-Ming Li
De-Ming Li
LSLi-Ren Shen
Li-Ren Shen
HZHai-Rong Zhang
Hai-Rong Zhang
ZCZhi-Ling Chen
Zhi-Ling Chen
ZZZhentang Zhao
Zhentang Zhao
Because of its excellent dose distribution, proton therapy is becoming increasingly popular in the medical application of cancer treatment. A synchrotron-based proton therapy facility was designed and constructed in Shanghai. The synchrotron, beam delivery system, and other technical systems were commissioned and reached their expected performances. After a clinical trial of 47 patients was finished, the proton therapy facility obtained a registration certificate from the National Medical Products Administration. The characteristics of the accelerator and treatment systems are described in this article.

1 January 2019 in MethodsX
Verified
Journal Article
Open access
HSHang Shu
Hang Shu
CYChongxian Yin
Chongxian Yin
HZHaiyang Zhang
Haiyang Zhang
Ming LiuMing Liu
Ming Liu
MZMan-Zhou Zhang
Man-Zhou Zhang
MMMichael Farley Moyers
Michael Farley Moyers
The Shanghai Advanced Proton Therapy facility (SAPT) is a hospital-based facility that began construction in December of 2014 with commissioning of the first scanned proton beam line starting in October of 2017. Proton beams are extracted from a synchrotron accelerator with energies between 70 and 235 MeV. Beam delivery uses the modulated scanning and energy stacking techniques to produce a maximal scanning area of 40 × 30 cm2 at the iso-center. Prior to clinical use, the beam delivery system was characterized and calibrated following the guidelines of the IEC 62667 medical electronic equipment standard including the spot size in air, spot position, depth dose distributions, and lateral dose profiles, as well as the beam monitor calibrations following the IAEA TRS-398 recommendations with small differences. •The measured dosimetric results showed that the full width at half maximum (FWHM) for the beam spot size in air varied approximately from 6 mm to 13 mm. The dose fall-off (DDF) derived from the measured depth dose in water varied from 4.7 mm at 235 MeV to 0.7 mm at 70 MeV. The homogeneity of the scanned field was better than 2% for various energies as expected.•Furthermore, the beam reproducibility and proportionality delivery accuracy was also stable with the results better than 0.1% and 1% respectively. Finally, the dose monitor calibration factor, its reproducibility and stability were tested. Reproducibility tests exhibited a standard deviation (SD) result of less than 1% during the test period.•All the measured dosimetric parameters showed that the design specifications were well achieved and the results are suitable for being used as a part of the clinical commissioning and quality assurance program for treating patients.

2 August 2017 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
YYYu-Hui Yang
Yu-Hui Yang
MZMan-Zhou Zhang
Man-Zhou Zhang
DLDe-Ming Li
De-Ming Li

3 October 2023 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
YSYing Shi
Ying Shi
MZMan-Zhou Zhang
Man-Zhou Zhang
LOLian-Hua Ou-Yang
Lian-Hua Ou-Yang
ZCZhi-Ling Chen
Zhi-Ling Chen
XLXiu-Fang Li
Xiu-Fang Li
DLDe-Ming Li
De-Ming Li

16 June 2021 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
MGMeng-Ya Guo
Meng-Ya Guo
XLXiu-Fang Li
Xiu-Fang Li
JWJie Wang
Jie Wang
QLQi Liu
Qi Liu
XDXiu-Zhen Deng
Xiu-Zhen Deng
ZCZhi-Ling Chen
Zhi-Ling Chen

19 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLibing Zhu
Libing Zhu
MZMan-Zhou Zhang
Man-Zhou Zhang
XXXincheng Xiang
Xincheng Xiang
XWXiangang Wang
Xiangang Wang
Research conducted to-date, makes use of the IBA-Lynx scintillating screen and radiochromic film to analyze the proton field uniformity for dose-area product (DAP) determination. In this paper, the machine log file based reconstruction is proposed to calculate the field uniformity to simplify the measurement. In order to calculate the field uniformity, the dose distribution is reconstructed based on the machine log file with matRad (an open source software for analytical dose calculation in MATLAB). After acquisition of the dose distribution, the field flatness and symmetry are calculated automatically for different proton energies. A comprehensive comparison of DAP determined with Bragg peak chamber (BPC) and Markus chamber (MC) is presented. The actual delivered dose is reconstructed with the log file to analyze the lateral dose distribution of the scanned field. DAP of different energies are calculated ranging from 70.6 MeV to 235 MeV. The percentage difference is calculated, illustrating the DAP discrepancy between the MC and BPC to the mean value. The percentage difference ranges from −0.19% to 1.26%. The variation between DAP measured with the BPC and MC peaks at −2.5%. The log file based reconstruction to calculate field uniformity can be an alternative for DAP determination. The direct method using a large-area Bragg peak chamber is investigated. The two methods to determine DAP and calibrate beam monitor illustrate consistent results.