This paper presents a MEMS electrochemical angular accelerometer with a silicon-based four-electrode structure, which was made of thousands of interconnected microchannels for electrolyte flow, anodes uniformly coated on structure surfaces and cathodes located on the sidewalls of flow holes. From the perspective of device fabrication, in this study, the previously reported multi-piece assembly was simplified into single-piece integrative manufacturing, effectively addressing the problems of complex assembly and manual alignment. From the perspective of the sensitive structure, in this study, the silicon-based four-electrode structure featuring with complete insulation layers between anodes and cathodes can enable fast electrochemical reactions with improved sensitivities. Numerical simulations were conducted to optimize the geometrical parameters of the silicon-based four-electrode structure, where increases in fluid resistance and cathode area were found to expand working bandwidths and improve device sensitivity, respectively. Then, the silicon-based four-electrode structure was fabricated by conventional MEMS processes, mainly composed of wafer-level bonding and wafer-level etching. As to device characterization, the MEMS electrochemical angular accelerometer with the silicon-based four-electrode structure exhibited a maximum sensitivity of 1458 V/(rad/s2) at 0.01 Hz and a minimum noise level of −164 dB at 1 Hz. Compared with previously reported electrochemical angular accelerometers, the angular accelerometer developed in this study offered higher sensitivities and lower noise levels, indicating strong potential for applications in the field of rotational seismology.
1 January 2024 in Applied Bionics and Biomechanics
Real‐time gait estimation is important for the synchrony control of robotic exoskeleton to provide walking assistance. However, for stroke patients with hemiplegic paralysis, the gait pattern is very complex. Accurate and timely gait intention recognition is therefore difficult. To achieve human–robot synchrony control for an unilateral knee exoskeleton, a gait intention recognizer coupling the adaptive frequency oscillator (AFO) and back propagation neural networks (BPNN) is proposed in this paper. The BPNN is trained with gait data of healthy subjects and stroke patients to improve the accuracy of recognized gait pattern, which is then imported into flexible interaction module to provide appropriate assistance. To evaluate the performance of gait intention recognition, three stroke patients were recruited to conduct level ground walking tests. The kinematic and biomechanical data were captured in each test and processed for the evaluation. Experimental results demonstrate the effectiveness of gait intention recognition and movement assistance.
27 February 2025 in IEEE Transactions on Instrumentation and Measurement
Sensitive micro-electrodes, the key element in electrochemical seismometers (ECS), employ a crucial influence on the ECS performance. Currently, the developments of ECSs and micro-electrode chips tend to primarily straightforward fabrication, monolithic integration of four electrodes and high performance. This work elucidated the effect of structural parameters of micro-electrode chips on performances of sensors through a mathematical model and finite element simulations, resulting in optimized parameters to design the micro-electrode chips of broadband ECSs. The chips featured large depth to diameter ratio micro-vias and monolithic integration of four micro-electrodes, fabricated by a tailored manufacturing approach based on double-sided DRIE and tilted sputtering. The ECSs assembled with the chips demonstrated the widest bandwidth and great sensitivity, i.e., peak sensitivity of 6221 V/(m/s) @ 3 Hz, bandwidth of 0.7 Hz - 100 Hz, as well as excellent consistency, compared with diverse ECSs. Moreover, the ECSs exhibited great vibration detection capability by a random vibration detection in contrast to commercial CME6011. The bandwidth of the broadband ECS was expanded from 0.00417 Hz to 100 Hz with low noise-level by utilizing a close-loop system based on circuit compensation and force-balancing negative feedback, demonstrating the great application potential in fields of broadband seismometers.
6 November 2023 in IEEE Transactions on Instrumentation and Measurement
This article develops a microelectrochemical rotational vibration sensor with silicon-on-insulator-based (SOI-based) microelectrodes used for seismic monitoring. The incoming rotational vibration is translated into currents through electrochemical reactions that occur on microelectrodes. Theoretical analysis and numerical simulations were carried out to model the rotational vibration sensor with key parameters optimized. The developed SOI-based microelectrodes were fabricated into mesh structures based on microfabrication technology and assembled to form the microelectrochemical rotational vibration sensor. The characterization results showed that the rotational vibration sensor featured a high sensitivity of 270 V/(rad/s2), a low noise level of $1.99\times 10^{-8}$ (rad/s2)/Hz1/2, and no responses to linear vibrations. The detection of a natural earthquake indicated that the developed microelectrochemical rotational vibration sensor can be further used in seismology for seismic monitoring.
This paper presents a novel approach to realize an electrochemical angular accelerometer with a compact size and a wide measurement range. For the first time, anodic bonding technology was utilized to create a chip-level packaged MEMS electrochemical angular accelerometer with a compact glass-silicon-glass triple layer structure, consisting primarily of a silicon-on-glass (SOG) wafer for angular acceleration sensitivities and a glass cap to form a toroid microchannel. To realize a wide range of angular acceleration measurements, the novel asymmetric planar electrodes with expanded cathode width and inter-cathode space were deployed on the silicon layer of the SOG wafer to improve the ion reaction of the cathodes more thoroughly. Besides, a narrower flow channel structure was achieved through the glass cap with a cavity to increase flow resistance. Testing results indicated that it has a more comprehensive measurement range (up to 500°/s²) and a much higher dynamic range(-130dB@1Hz), marking a notable advance over its previously reported equivalents. This study presents an innovative method for creating electrochemical angular accelerometers, which are specifically designed to measure rotational motion with substantial angle variations.