Quanquan Liu

Dr. Quanquan Liu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2020 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
QLQuanquan Liu
Quanquan Liu
XGXiaoyi Gu
Xiaoyi Gu
NTNing Tan
Ning Tan
Hongliang RenHongliang Ren
Hongliang Ren
Performing a successful robotic grasping to uncertain objects in unstructured environments is challenging. This study presents a new compliant soft robotic gripper for objects handling and cap manipulation through the coordination of three soft fingers and in-hand manipulation. The experiments are conducted to validate that the soft robotic gripper can successfully realize simultaneous grasping and capping manipulations with only one flexible shaft actuation for every single soft finger.

15 March 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
QLQuanquan Liu
Quanquan Liu
CWChunbao Wang
Chunbao Wang
JLJianjun Long
Jianjun Long
TSTongyang Sun
Tongyang Sun
LDLihong Duan
Lihong Duan
ZWZhengzhi Wu
Zhengzhi Wu
A large amount of hemiplegic survivors are suffering from motor impairment. Ankle rehabilitation exercises act an important role in recovering patients’ walking ability after stroke. Currently, patients mainly perform ankle exercise to reobtain range of motion (ROM) and strength of the ankle joint under a therapist’s assistance by manual operation. However, therapists suffer from high work intensity, and most of the existed rehabilitation devices focus on ankle functional training and ignore the importance of neurological rehabilitation in the early hemiplegic stage. In this paper, a new robotic ankle rehabilitation platform (RARP) is proposed to assist patients in executing ankle exercise. The robotic platform consists of two three-DOF symmetric layer-stacking mechanisms, which can execute ankle internal/external rotation, dorsiflexion/plantarflexion, and inversion/eversion exercise while the rotation center of the distal zone of the robotic platform always coincides with patients’ ankle pivot center. Three exercise modes including constant-speed exercise, constant torque-impedance exercise, and awareness exercise are developed to execute ankle training corresponding to different rehabilitation stages. Experiments corresponding to these three ankle exercise modes are performed, the result demonstrated that the RARP is capable of executing ankle rehabilitation, and the novel awareness exercise mode motivates patients to proactively participate in ankle training.

5 July 2017 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
TSTongyang Sun
Tongyang Sun
HLHua Li
Hua Li
QLQuanquan Liu
Quanquan Liu
LDLihong Duan
Lihong Duan
MLMeng Li
Meng Li
YWYulong Wang
Yulong Wang
The hemiplegic rehabilitation state diagnosing performed by therapists can be biased due to their subjective experience, which may deteriorate the rehabilitation effect. In order to improve this situation, a quantitative evaluation is proposed. Though many motion analysis systems are available, they are too complicated for practical application by therapists. In this paper, a method for detecting the motion of human lower limbs including all degrees of freedom (DOFs) via the inertial sensors is proposed, which permits analyzing the patient’s motion ability. This method is applicable to arbitrary walking directions and tracks of persons under study, and its results are unbiased, as compared to therapist qualitative estimations. Using the simplified mathematical model of a human body, the rotation angles for each lower limb joint are calculated from the input signals acquired by the inertial sensors. Finally, the rotation angle versus joint displacement curves are constructed, and the estimated values of joint motion angle and motion ability are obtained. The experimental verification of the proposed motion detection and analysis method was performed, which proved that it can efficiently detect the differences between motion behaviors of disabled and healthy persons and provide a reliable quantitative evaluation of the rehabilitation state.

1 January 2020 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
CWChunbao Wang
Chunbao Wang
ZSZhengdi Sun
Zhengdi Sun
JLJianjun Long
Jianjun Long
JWJianjun Wei
Jianjun Wei
XCXiaojiao Chen
Xiaojiao Chen
ZWZhengzhi Wu
Zhengzhi Wu
BACKGROUND: Traditional Chinese medicine (TCM) massage has a better effect on treating infant diarrhea compared to medical treatment. The TCM doctors need to be trained to master professional massage techniques. Traditional Chinese massage training relies on the students’ understanding ability, and cannot accurately record the students’ operating information. This situation leads to insufficient clinical massage skills of the students. OBJECTIVE: This paper proposes a novel massage training platform to quantitatively perceive the massage techniques of students. METHODS: The paper proposed two types of flexible array sensors, which are arranged and placed into the bionic baby according to the position of the human acupoints. The massage techniques of the training object can be analyzed and evaluated during the massage process by studying the voltage from pressure sensors when the participants massage the bionic infant. RESULTS: A medical student was invited to conduct the massage training experiment, and the massage information included the operating strength, massage frequency and the massage direction, which were recorded and analyzed through the training platform. CONCLUSION: The platform can perceive the parameters related to the massage technique of students and can be used for medical training.

7 August 2017 in Assembly Automation
Verified
Journal Article
Closed access
QLQuanquan Liu
Quanquan Liu
CSChaoyang Shi
Chaoyang Shi
BZBo Zhang
Bo Zhang
CWChunbao Wang
Chunbao Wang
LDLihong Duan
Lihong Duan
MFMasakatsu G. Fujie
Masakatsu G. Fujie
Purpose: Paediatric congenital esophageal atresia surgery typically requires delicate and dexterous operations in a narrow and confined workspace. This study aims to develop a novel robot assisted surgical system to address these challenges. Design/methodology/approach: The proposed surgical robot consists of two symmetrical slave arms with nine degree of freedoms each. Each slave arm uses a rigid-dexterous configuration and consists of a coarse positioning manipulator and a distal fine operation manipulator. A small Selective Compliance Assembly Robot Arm (SCARA) mechanism was designed to form the main component of the coarse positioning unit, ensuring to endure large forces along the vertical direction and meet the operational demands. The fine positioning manipulator applied the novel design using flexible shafts and universal joints to achieve delicate operations while possessing a high rigidity. The corresponding kinematics has been derived and then was validated by a co-simulation that was performed based on the combined use of Adams and MATLAB with considering the real robot mass information. Experimental evaluations for the tip positioning accuracy and the ring transfer tasks have been performed. Findings: The simulation was performed to verify the correctness of the derived inverse kinematics and demonstrated the robot’s flexibility. The experimental results illustrated that the end-effector can achieve a positioning accuracy within 1.5 mm in a confined 30 × 30 × 30 mm workspace. The ring transfer task demonstrated that the surgical robot is capable of providing a solution for dexterous tissue intervention in a narrow workspace for paediatric surgery. Originality/value: A novel and compact surgical assist robot is developed to support delicate operations by using the dexterous slave arm. The slave arm consists of a SCARA mechanism to avoid experiencing overload in the vertical direction and a tool manipulator driven by flexible shafts and universal joints to provide high dexterity for operating in a narrow workspace.

15 January 2018 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
SWShang Wanfeng
Shang Wanfeng
CWChunbao Wang
Chunbao Wang
LDLihong Duan
Lihong Duan
QLQuanquan Liu
Quanquan Liu
ZWZhengzhi Wu
Zhengzhi Wu
Metallic glass (MG) microwires are unique material with great potentials for sensor, actuator, biomaterial, etc., owing to its advanced mechanical properties. Yet, the defects on its surface, which seriously affected its performance, are still very difficult to be investigated due to the lack of precise manipulation and flexible imaging techniques. Herein, we report an in situ detection method for MG microwire by integrating the automatic image processing and a rotational nanorobotic system. First, the MG microwire is fixed on the self-developed rotational nanorobotic system and assembled inside scanning electron microscope. Then, a dynamic control strategy is proposed to rotate the MG microwire by 360°, then to realize the full-orientation imaging of the MG microwire. Meanwhile, defect detection method is utilized to identify the defects on the MG microwire during rotation. The results indicate that our method can identify spine and embossment defects of the sample after manufacturing. This research offers a powerful tool for the MG microwire defect detection, which can be adopted to proceed guidance for improving metallic glass microwire' manufacturing process.