Jun Xiao

Dr. Jun Xiao


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2018 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
YHYong Hu
Yong Hu
QLQiang Li
Qiang Li
BWBao-Gang Wei
Bao-Gang Wei
XZXian-Sen Zhang
Xian-Sen Zhang
TTTahsin Tarik Torsha
Tahsin Tarik Torsha
ZSZhan-Jun Shi
Zhan-Jun Shi
Total knee arthroplasty is regarded as the most effective treatment for severe knee osteoarthritis. The influential factors of blood loss in total knee arthroplasty remain controversial. The study aims to explore the influential factors of blood loss in total knee arthroplasty comprehensively. Three hundred and four osteoarthritis patients undergoing unilateral primary total knee arthroplasty were enrolled. Demographic characteristics, laboratory results, surgical protocol, and hemostatic and anticoagulation drugs were collected. Estimation of blood loss was calculated using the Gross equation. Multivariable stepwise linear regression analysis was performed to find out the influential factors. Total blood loss reached the biggest volume (1346 ± 671 mL) in the post-operative third day. Hidden blood loss reached 465 ± 358 mL. Gender, tranexamic acid, prosthesis type, and drainage were proven to be positively correlated with the total blood loss (all P < 0.05). Male appeared to suffer more surgical blood loss than female. Posterior cruciate stabilizing prosthesis might lead to more surgical blood loss than posterior cruciate retaining prosthesis. Tranexamic acid could effectively reduce total blood loss while drainage might increase bleeding. Gender and anticoagulation drugs were correlated with hidden blood loss (both P < 0.05). Low molecular weight heparin resulted in less hidden blood loss than rivaroxaban. Posterior cruciate retaining prosthesis and topical use of tranexamic acid were preferred to reduce total blood loss. Drainage was not recommended due to the risk of increasing bleeding. Low molecular weight heparin was recommended to prevent venous thrombosis.

15 November 2022 in Blood
Verified
Journal Article
Open access
WCWenming Chen
Wenming Chen
CFChengcheng Fu
Chengcheng Fu
BFBaijun Fang
Baijun Fang
ALAi-Bin Liang
Ai-Bin Liang
ZXZhongjun Xia
Zhongjun Xia
ZLZonghai Li
Zonghai Li
Background: Zevorcabtagene autoleucel (Zevor-cel, CT053), a fully human autologous anti- B-cell maturation antigen (BCMA) chimeric antigen receptor (CAR) T-cell

11 March 2019 in Journal of Back and Musculoskeletal Rehabilitation
Verified
Journal Article
Closed access
PDF file
ZHZhi-Fa Huang
Zhi-Fa Huang
BLBing-Quan Lin
Bing-Quan Lin
TTTahsin Tarik Torsha
Tahsin Tarik Torsha
SDSabil Dilshad
Sabil Dilshad
DYDe-Sheng Yang
De-Sheng Yang
JXJun Xiao
Jun Xiao
BACKGROUND: Piriformis syndrome (PS) is an entrapment of the sciatic nerve by the piriformis muscle, or myofascial pain from the piriformis muscle. OBJECTIVE: The aim of this study was to investigate the effectiveness of “Mannitol plus Vitamins B” re

7 June 2017 in Biomedical Materials
Verified
Journal Article
Closed access
PDF file
LZLei Zhang
Lei Zhang
XKXiurong Ke
Xiurong Ke
LLLingzhi Lin
Lingzhi Lin
JXJun Xiao
Jun Xiao
XYXianyan Yang
Xianyan Yang
ZSZhanjun Shi
Zhanjun Shi
Due to the low strength and high brittleness of 45S5 Bioglass®, it is still a great challenge for the three-dimensional porous 45S5 Bioglass® to treat mechanically required loaded bone defects. Therefore, 45S5 Bioglass®-derived bioactive glass-ceramic (BGC) porous scaffolds were fabricated at a low temperature sintering condition with and without the addition of 4% low-melting ZnO/B2O3 (ZB) bioactive glass as a reinforcing agent and using 350- or 500 μm paraffin microspheres as a porogen. The pore structure characterization for the scaffolds indicated that the scaffolds containing 4% ZB had very good macroporous structures of ~313 and ~448 μm in pore size and over 70% porosity with appreciable strength (>15 MPa), which was about four times higher than that those manufactured without ZB and with 350 μm porogen scaffolds. The open porosity was decreased with the addition of 4% ZB but the interconnected pore percentage (>50 μm) was increased with increasing the porogen size from 350 to 500 μm. In vivo investigations revealed that the stronger scaffolds containing 4% ZB and 500 μm porogen were particularly beneficial for osteogenic capacity in critical size femoral bone defects, accompanied with an accelerated bone ingrowth (6–18 weeks) and the material itself experiencing mild resorption. In contrast, both the scaffolds with smaller pore sizes exhibited a low level of new bone ingrowth (<32%) after 6–12 weeks implantation. These results suggest a promising application of such 45S5 Bioglass®-derived BGC scaffolds in a clinical setting, especially for mechanically loaded bone defects.

8 June 2020 in Drug Delivery and Translational Research
Verified
Journal Article
Closed access
PDF file
JXJun Xiao
Jun Xiao
YHYong Hu
Yong Hu
LHLin Huang
Lin Huang
ZHZhi-Fa Huang
Zhi-Fa Huang
WJWei-Zhou Jiang
Wei-Zhou Jiang
ZSZhan-Jun Shi
Zhan-Jun Shi

6 March 2022 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
WLWeilu Liu
Weilu Liu
YHYong Hu
Yong Hu
ZHZhifa Huang
Zhifa Huang
ZSZhanjun Shi
Zhanjun Shi
JXJun Xiao
Jun Xiao