Aims : Whether isolated diastolic hypertension (IDH), as defined by the 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guideline, is associated with cardiovascular disease (CVD) has been disputed. We aimed to further study the associations of IDH with (i) subclinical CVD in the form of coronary artery calcium (CAC), (ii) incident systolic hypertension, and (iii) CVD events. Methods and results : We used multivariable-adjusted logistic and Cox regression to test whether IDH by 2017 ACC/AHA criteria (i.e. systolic blood pressure 0 of 0.88 (95% CI 0.66, 1.17)]. Similarly, while IDH was associated with incident systolic hypertension, there was no statistically significant associations with incident CVD [hazard ratio 1.19 (95% CI 0.77, 1.84)] or death [hazard ratio 0.94 (95% CI 0.65, 1.36)] over 13 years in MESA. In a stratified meta-analysis of eight cohort studies (10 037 843 participants), the 2017 IDH definition was also not consistently associated with CVD and the relative magnitude of any potential association was noted to be numerically small [e.g. depending on inclusion criteria applied in the stratification, the adjusted hazard ratios ranged from 1.04 (95% CI 0.98, 1.10) to 1.09 (95% 1.03, 1.15)]. Conclusion : The lack of consistent excess in CAC or CVD suggests that emphasis on healthy lifestyle rather than drug therapy is sufficient among the millions of middle-aged or older adults who now meet the 2017 ACC/AHA criteria for IDH, though they require follow-up for incident systolic hypertension. These findings may not extrapolate to adults younger than 40 years, motivating further study in this age group.
Atrioventricular (AV)-synchronous single-chamber leadless pacing using a mechanical atrial sensing algorithm produced high AV synchrony in clinical trials, but clinical practice experience with these devices has not yet been described. To describe pacing outcomes and programming changes with AV-synchronous leadless pacemakers in clinical practice. Consecutive patients without persistent atrial fibrillation who received an AV-synchronous leadless pacemaker and completed follow-up between February 2020 and April 2021 were included. We evaluated tracking index (atrial mechanical sense followed by ventricular pace [AM-VP] divided by total VP), total AV synchrony (sum of AM-ventricular sense [AM-VS], AM-VP, and AV conduction mode switch), use of programming optimization, and improvement in AV synchrony after optimization. Fifty patients met the inclusion criteria. Mean age was 69 ± 16.8 years, 24 (48%) were women, 24 (48%) had complete heart block, and 17 (34%) required ≥50% pacing. Mean tracking index was 41% ± 34%. Thirty-five patients (70%) received ≥1 programming change. In 36 patients with 2 follow-up visits, tracking improved by +9% ± 28% (P value for improvement = .09) and +18% ± 19% (P = .02) among 15 patients with complete heart block. Average total AV synchrony increased from 89% [67%, 99%] to 93% [78%, 100%] in all patients (P = .22), from 86% [52%, 98%] to 97% [82%, 99%] in those with complete heart block (P = .04), and from 73% [52%, 80%] to 78% [70%, 85%] in those with ≥50% pacing (P = .09). In patients with AV-synchronous leadless pacemakers, programming changes are frequent and are associated with increased atrial tracking and increased AV synchrony in patients with complete heart block.
13 September 2023 in Journal of Cardiovascular Electrophysiology