Kikelomo Mabinuola Arifalo

Dr. Kikelomo Mabinuola Arifalo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
AAAdemola Adamu
Ademola Adamu
KAKikelomo Mabinuola Arifalo
Kikelomo Mabinuola Arifalo
FAFrancis Abulude
Francis Abulude
Individuals who spend most of their time indoors are especially sensitive to indoor air quality (IAQ), which significantly impacts their general well-being and health. Traditional IAQ measurement techniques, however, are frequently pricy, complicated, and labor-intensive. In this study, we used a low-cost, simple-to-use, and handy sensor system to track the levels of carbon dioxide (CO2), nitrogen dioxide (NO2), ozone (O3), particulate matter (PM1.0, PM2.5, and PM10), temperature, and relative humidity (RH) in a laboratory at the Bamidele Olomilua University of Education, Science, and Technology in Ikere-Ekiti for a month. We contrasted the outcomes with other benchmarks and WHO recommendations. However, the NO2 levels (144.00–303.00 ppb) exceeded the suggested levels (National Institute for Occupational Safety and Health (NIOSH)—70 ppb; National Ambient Air Quality Standards (NAAQS)—100 ppb; National Environmental Standards and Regulations Enforcement Agency (NESREA)—120 ppb; and World Health Organization (WHO)—25 ppb), suggesting a possible cause of indoor contaminants. We also noticed that the temperature and humidity varied considerably throughout the day, which impacted the inhabitants’ thermal comfort and ventilation. The principal component analysis (PCA) findings indicate that particulate matter, the weather, photochemical reactions, and combustion processes are the key contributors to fluctuation in the air quality measurements. Based on their quantities and relationships, these elements can have a variety of effects on both the natural environment as well as well-being. Our monitoring device can give immediate information and warnings, assisting in locating and reducing indoor airborne pollutant sources and enhancing indoor air quality (IAQ). This work shows that adopting a low-cost sensor system for IAQ measurement in underdeveloped nations, where such data are sparse and frequently erroneous, is both feasible and beneficial.

Verified
Conference Paper
Open access
PDF file
Francis Olawale AbuludeFrancis Olawale Abulude
Francis Olawale Abulude
AAAKINNUSOTU AKINYINKA
AKINNUSOTU AKINYINKA
EAEbenezer Alaba Adeoya
Ebenezer Alaba Adeoya
SMSamson Olatunde Mabayoje
Samson Olatunde Mabayoje
SOSamel Oluwagbayide
Samel Oluwagbayide
AAAdemola Adamu
Ademola Adamu
The study of water quality is crucial given the amount of industrial, agricultural, and other human activities at the sampling sites. The aim of the study was to assess the physicochemical characteristics and selected contamination patterns of water samples in Nigeria. This study used conventional analytical techniques to analyze the physicochemical parameters in water samples from 33 sampling sites (dug wells, boreholes, rivers, and rainwater) in three different states (Ekiti, Osun, and Ondo) of Nigeria. These parameters included pH, total dissolved solids (TDS), electrical conductivity (EC), temperature, relative humidity (RH), and four elemental parameters (Ca, Na, Fe, and Cu). The enrichment factor (EF), contamination factor (CF), and metal index (MI) were used to characterize the data. Temperature (28.17 °C), TDS (130.2 mg/L), EC (260.0 μS/cm), pH (6.88), Na (14.47 ppm), Ca (25.74 ppm), Fe (0.49 ppm), and Cu (0.08 ppm) were the average values from the results. Na and Ca had a direct relationship with one another. The levels of heavy metals were below those recommended by the Nigerian Industrial Standard for Drinking Water Quality (NISDQW) and the World Health Organization (WHO). The metal levels in the water samples were over 1.5, which is the threshold value indicated by the EF classifications. In particular, EFs were moderate to significantly enriched. All element CFs were below the Level 1 pollution threshold. The water samples are pure based on the MI’s rating of water quality. Human and natural activities may represent a risk to the local public health; hence, it is highly advisable that all stakeholders adopt rapid and long-lasting collective action to limit pollution levels as part of the water quality governance system.

Verified
Conference Paper
Open access
PDF file
FAFrancis Abulude
Francis Abulude
KAKikelomo Mabinuola Arifalo
Kikelomo Mabinuola Arifalo
AAAdemola Adamu
Ademola Adamu
AKAmoke Monisola Kenni
Amoke Monisola Kenni
AAAkinyinka Akinnusotu
Akinyinka Akinnusotu
SASunday Acha
Sunday Acha
According to studies, indoor air quality is a major concern because of the health risks it poses. In Nigeria, little is done to improve indoor air quality and the toxicity potentials (TP) of PM2.5 and PM10. We assessed the levels of PM2.5, PM10, the PM2.5/PM10 ratio, and the toxicity potential of a commercial area in Akure, Ondo State, Nigeria, in this study. For the three-month assessment of the study area (March to May 2022), a low-cost sensor (Canāree A1) was used. The results depict the following: 73.23 ± 53.94 µg/m3 (PM2.5), 68.58 ± 50.64 µg/m3 (PM10), 0.93 ± 0.02 (PM2.5/PM10 ratio), and toxicity potentials (PM2.5—2.74 ± 0.04 and PM10—1.47 ± 0.02). Both PM values exceed the WHO standard limits. The PM values differ significantly. The average ratio value indicates that anthropogenic activities in the area contribute significantly to the high PM2.5 levels. It should be noted that TP greater than 1 indicates a potential health risk. The TP values obtained in this study are greater than 1, indicating that the environment may be harmful to the vulnerable. Based on these findings, efforts should be directed toward continuous monitoring of this study area and Akure as a whole.

Verified
Conference Paper
Open access
PDF file
FAFrancis Abulude
Francis Abulude
UDUsha Damodharan
Usha Damodharan
SASunday Acha
Sunday Acha
AAAdemola Adamu
Ademola Adamu
KAKikelomo Mabinuola Arifalo
Kikelomo Mabinuola Arifalo
Owing to the effect on people, livestock, and materials, air pollution is a global hazard. To this end, stakeholders have taken on the challenge of quantifying the environment with the use of tools and eventually using the data produced to provide solutions to the problems. However, low-cost sensors and the IoT have come to the rescue due to the high cost and operational complexity of equipment and methodologies in environmental monitoring. They are relatively inexpensive and reliable. It is on this assumption that we have decided to use the World Air Quality satellite data supplied by air matters.com. This study is a 40-day preliminary work in which air quality (AQI, PM2.5, PM10, NO2, CO, SO2, and O3) and meteorological (temperature, humidity, and wind speed) parameters were monitored. The data collected are for five locations in Lagos State, Nigeria (Ojodu, Opebi, Ikeja, Maryland, and Eti-Osa). The data obtained were subjected to basic descriptive, multivariate and time series statistical analyses. The findings showed that the AQI of all locations presented the levels of contamination as 'Unhealthy for Vulnerable Groups', there were relationships between the parameters monitored and meteorological influences, and the effects of natural and man-made activities may be the sources of the elevated pollutants throughout the locations.

20 November 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
FAFrancis Abulude
Francis Abulude
FDFagbayide Samuel Dare
Fagbayide Samuel Dare
AAAKINNUSOTU AKINYINKA
AKINNUSOTU AKINYINKA
KAKikelomo Mabinuola Arifalo
Kikelomo Mabinuola Arifalo
AAAdemola Adamu
Ademola Adamu
AKAmoke Monisola Kenni
Amoke Monisola Kenni
This study presents a comprehensive assessment of indoor particulate matter (PM) concentrations, focusing on PM1, PM2.5, and PM10 in five Primary Health Centers (PHCs): Arakale, Federal College of Agriculture (FECA), Iju, Oba-Ile, and Owode within Akure Local Government Areas in Nigeria. The primary novelty of this research lies in its detailed exploration of the toxicity potential of these PM fractions, providing valuable insights into the local air quality and associated health risks. The study assesses the health implications by calculating the toxicity potential (TP), Relative Risk (RR), Excess Risk (ER), and Attributable Fractions (AF) for cardiopulmonary and lung cancer mortality. The results reveal varying RR values for all-cause mortality, with Arakale showing a slight elevation (RR: 1.061), indicating potential health risks. ER values for cardiopulmonary mortality range from 14.728±7.25 to 19.04±0.38, emphasizing the substantial excess risk associated with long-term PM2.5 exposure. The study also uncovers AF for cardiopulmonary mortality ranging between 11.03±0.31 to 19.22±0.04, underscoring the significant contribution of PM to cardiovascular and respiratory health risks. Similarly, AF for lung cancer mortality ranges from 10.03±0.012 to 17.13±0.10, highlighting the substantial association between PM2.5 exposure and lung cancer risk. These findings underscore the urgent need for targeted air quality management strategies and public health interventions in the studied locations to mitigate the heightened health risks associated with particulate matter pollution. The calculated RR, ER, and AF values offer crucial insights into the complex relationship between PM exposure and adverse health outcomes, providing a foundation for informed decision-making and future research endeavors.

12 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
FAFrancis Abulude
Francis Abulude
AAAKINYINKA AKINNUSOTU
AKINYINKA AKINNUSOTU
SOSamel Oluwagbayide
Samel Oluwagbayide
KAKikelomo Mabinuola Arifalo
Kikelomo Mabinuola Arifalo
AAAdemola Adamu
Ademola Adamu
ASAcha Sunday
Acha Sunday
This study presents a comparative analysis of indoor air quality (IAQ) across health centers in Arakale, Iju, Owode, FECA, and Oba Ile, Ondo State, Nigeria. Particle count data were analyzed to identify common trends, similarities, and differences in IAQ parameters, with the aim of informing targeted interventions for improving indoor air quality in healthcare settings. The findings reveal consistent positive skewness in particle count distributions, indicating occasional spikes in pollution levels amidst generally lower concentrations. Fine particles in the size range of PC 2.5 were consistently dominant across all locations, emphasizing their significance in IAQ assessment. Similar variability in particle count data suggests comparable levels of fluctuations in IAQ among the health centers. However, variations in PCA patterns highlight unique factors influencing IAQ in specific locations, such as combustion sources and control strategies. Targeted interventions, including enhancing ventilation systems, controlling indoor pollution sources, and promoting smoking cessation programs, are proposed to mitigate health risks associated with indoor air pollution exposure. Ongoing monitoring and collaboration with environmental experts are crucial for assessing IAQ trends and implementing evidence-based interventions to safeguard the health of patients, staff, and visitors in healthcare facilities.