Tanveer Ahmed Shaik

Dr. Tanveer Ahmed Shaik


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JBJuan David Muñoz Bolaños
Juan David Muñoz Bolaños
TSTanveer Ahmed Shaik
Tanveer Ahmed Shaik
AMArkadiusz Miernik
Arkadiusz Miernik
Juergen PoppJuergen Popp
Juergen Popp
Christoph KrafftChristoph Krafft
Christoph Krafft
This study introduces a compact Raman spectrometer with a 1064 nm excitation laser coupled with a fiber probe and an inexpensive motorized stage, offering a promising alternative to widely used Raman imaging instruments with 785 nm excitation lasers. The benefits of 1064 nm excitation for biomedical applications include further suppression of fluorescence background and deeper tissue penetration. The performance of the 1064 nm instrument in detecting cancer in human bladder resectates is demonstrated. Raman images with 1064 nm excitation were collected ex vivo from 10 human tumor and non-tumor bladder specimens, and the results are compared to previously published Raman images with 785 nm excitation. K-Means cluster (KMC) analysis is used after pre-processing to identify Raman signatures of control, tumor, necrosis, and lipid-rich tissues. Hierarchical cluster analysis (HCA) groups the KMC centroids of all specimens as input. The tools for data processing and hyperspectral analysis were compiled in an open-source Python library called SpectraMap (SpMap). In spite of lower spectral resolution, the 1064 nm Raman instrument can differentiate between tumor and non-tumor bladder tissues in a similar way to 785 nm Raman spectroscopy. These findings hold promise for future clinical hyperspectral Raman imaging, in particular for specimens with intense fluorescence background, e.g., kidney stones that are discussed as another widespread urological application.

15 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJuan David Muñoz Bolaños
Juan David Muñoz Bolaños
TSTanveer Ahmed Shaik
Tanveer Ahmed Shaik
AMArkadiusz Miernik
Arkadiusz Miernik
Juergen PoppJuergen Popp
Juergen Popp
Christoph KrafftChristoph Krafft
Christoph Krafft
This study introduces a compact Raman spectrometer with a 1064 nm excitation laser coupled with a fiber probe and an inexpensive motorized stage, offering a promising alternative to widely used Raman imaging instruments with 785 nm excitation lasers. The benefits of 1064 nm excitation for biomedical applications include further suppression of fluorescence background and deeper tissue penetration. The performance of the 1064 nm instrument in detecting cancer in human bladder resectates is demonstrated. Raman images with 1064 nm excitation were collected ex vivo from 10 human tumor and non-tumor bladder specimens and the results are compared to previously published Raman images with 785 nm excitation. K-Means cluster (KMC) analysis is used after pre-processing to identify Raman signatures of control, tumor, necrosis, and lipid-rich tissues. Hierarchical cluster analysis (HCA) groups the KMC centroids of all specimens as input. The tools for data processing and hyperspectral analysis were compiled in an open source Python library called SpectraMap (SpMap). In conclusion, the 1064 nm Raman system can differentiate between tumor and non-tumor bladder tissues in a similar way to 785 nm Raman spectroscopy. These findings hold promise for future clinical hyperspectral imaging.

16 September 2026 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
SRShravan Raghunathan
Shravan Raghunathan
KWKristina Worch
Kristina Worch
CKChristoph Krafft
Christoph Krafft
VDVolker Deckert
Volker Deckert
ABAntje Burse
Antje Burse
TSTanveer Ahmed Shaik
Tanveer Ahmed Shaik
Resolving biochemical signatures associated with viral infection progression within individual living cells, without introducing fluorescent labels that demand genetic accessibility and may perturb the process under study, remains a challenge for conventional optical approaches. Optical photothermal infrared (OPTIR) spectroscopy addresses this by providing label-free vibrational contrast with molecular bond specificity in live cells, combining submicron spatial resolution with strong suppression of the water background in aqueous media. Here, OPTIR discrete wavenumber imaging and point spectroscopy were applied to follow baculovirus infection in live Spodoptera frugiperda (Sf) 9 cells carrying no fluorescent reporter. Cells were measured within a CaF₂ sandwich configuration at 3, 6, 12, and 24 h post-infection. Imaging at the amide II protein band (1545 cm⁻ 1 ) and a nucleic acid band (1086 cm⁻ 1 ) provided spatial discrimination between infected and uninfected cells at each time point, with balanced accuracy reaching 0.90, while point spectroscopy raised the pairwise balanced accuracy to 0.94 and confirmed the biochemical basis of the image contrast. Multiclass separation across time points reached an overall accuracy of 0.71. Single-cell heterogeneity was quantified by uniform manifold approximation and projection (UMAP), and cross-replicate reproducibility served as internal validation. These findings demonstrate that OPTIR enables label-free monitoring of viral infection in living cells using intrinsic biochemical signatures alone, providing a practical alternative to genetically encoded fluorescent reporters.