This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2–3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM1–PM2.5–PM10 readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM1, PM2.5, and PM10 concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room.

22 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MKMirosław Kwaśny
Mirosław Kwaśny
ABAneta Bombalska
Aneta Bombalska
MKMiron Kaliszewski
Miron Kaliszewski
MWMaksymilian Włodarski
Maksymilian Włodarski
KKKrzysztof Kopczyński
Krzysztof Kopczyński
The article presents the history of the development and the current state of the apparatus for the detection of interferents and biological warfare simulants in the air with the laser-induced fluorescence (LIF) method. The LIF method is the most sensitive spectroscopic method and also enables the measurement of single particles of biological aerosols and their concentration in the air. The overview covers both the on-site measuring instruments and remote methods. The spectral characteristics of the biological agents, steady-state spectra, excitation–emission matrices, and their fluorescence lifetimes are presented. In addition to the literature, we also present our own detection systems for military applications.

15 September 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
IKIzabela Kamińska
Izabela Kamińska
KFK. Fronc
K. Fronc
BSBożena Sikora
Bożena Sikora
MMM. Mouawad
M. Mouawad
ASA. Siemiarczuk
A. Siemiarczuk
DED. Elbaum
D. Elbaum
Upconverting/paramagnetic Gd2O3:1% Er3+, 18% Yb3+with Zn2+nanoparticles (NPs) permits one to perform optical imaging.

1 April 2011 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
ABAneta Bombalska
Aneta Bombalska
MMMonika Mularczyk-Oliwa
Monika Mularczyk-Oliwa
MKMirosław Kwaśny
Mirosław Kwaśny
MWMaksymilian Włodarski
Maksymilian Włodarski
MKMiron Kaliszewski
Miron Kaliszewski
ETElżbieta Trafny
Elżbieta Trafny

1 November 2012 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
MMMonika Mularczyk-Oliwa
Monika Mularczyk-Oliwa
ABAneta Bombalska
Aneta Bombalska
MKMiron Kaliszewski
Miron Kaliszewski
MWMaksymilian Włodarski
Maksymilian Włodarski
KKKrzysztof Kopczyński
Krzysztof Kopczyński
ETElżbieta Trafny
Elżbieta Trafny

16 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MKMiron Kaliszewski
Miron Kaliszewski
MWMaksymilian Włodarski
Maksymilian Włodarski
JMJaroslaw Mlynczak
Jaroslaw Mlynczak
BJBartłomiej Jankiewicz
Bartłomiej Jankiewicz
LALukas Auer
Lukas Auer
KKKrzysztof Kopczyński
Krzysztof Kopczyński
In this article, we present a versatile gas detector that can operate on an unmanned aerial vehicle (UAV) or unmanned ground vehicle (UGV). The device has six electrochemical modules, which can be selected to measure specific gases, according to the mission requirements. The gas intake is realized by a miniaturized vacuum pump, which provides immediate gas distribution to the sensors and improves a fast response. The measurement data are sent wirelessly to the operator’s computer, which continuously stores results and presents them in real time. The 2 m tubing allows measurements to be taken in places that are not directly accessible to the UGV or the UAV. While UAVs significantly enhanced the versatility of sensing applications, point gas detection is challenging due to the downwash effect and gas dilution produced by the rotors. In our work, we demonstrated the method of downwash effect reduction at aerial point gas measurements by applying a long-distance probe, which was kept between the UAV and the examined object. Moreover, we developed a safety connection protecting the UAV and sensor in case of accidental jamming of the tubing inside the examined cavity. The methods presented provide an effective gas metering strategy using UAVs.