Federica Galante

Dr. Federica Galante


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GSGiulia Sellaro
Giulia Sellaro
APAndrea Pella
Andrea Pella
Matteo PepaMatteo Pepa
Matteo Pepa
FGFederica Galante
Federica Galante
MCMario Ciocca
Mario Ciocca
GBGuido Baroni
Guido Baroni
This study describes a method for setup optimization in patient simulation for ocular proton therapy (OPT) at the National Center for Oncological Hadrontherapy (CNAO) in Pavia, Italy, with the aim of minimizing the occupancy time of clinical areas and streamlining the actual procedure. Setup repeatability is ensured by patient-specific immobilization tools and relies on the patient’s ability to maintain a stable gaze direction according to the treatment plan. This is facilitated by aligning a light source (LED) on a patient-specific base along the prescribed gaze direction. At CNAO, a dedicated Eye-Tracking System (ETS) was designed to provide the patient with a visible source of light aligned to the desired gaze direction. The ETS position is defined prior to treatment planning, relying on optical-tracking guidance and comparing the position of passive markers fixed on the ETS chassis with patient-specific models prepared offline in accordance with the desired geometry. OPT at CNAO started in 2016 and may be considered as a consolidated clinical routine. However, all the preparation phases, including patient-specific ETS models and setup, still require long sessions in clinical areas such as the computed tomography (CT) and the treatment rooms, with a non-negligible impact on other activities. This study describes a novel approach for patient-specific definition of the ETS position and orientation, aiming at minimizing the time required for preparatory activities inside clinical areas. To minimize the occurrence of biases and to reproduce as much as possible a real end-to-end approach, we included in the analysis data of patients that received OPT in our facility. The study was performed in parallel, carrying out the alignment with the standard method currently used in the clinical workflow of CNAO and with the proposed method. Results are presented as 3D residuals and gaze deviations, comparing ETS alignment based on the new approach with respect to the clinical standard method. The preliminary results of this study are evidence of the capability of the procedure to align the ETS position, allowing performing of the procedure in a non-clinical dedicated room.

28 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Matteo PepaMatteo Pepa
Matteo Pepa
APAndrea Pella
Andrea Pella
GSGiulia Sellaro
Giulia Sellaro
FGFederica Galante
Federica Galante
AMALFREDO MIRANDOLA
ALFREDO MIRANDOLA
GBGuido Baroni
Guido Baroni
The purpose of this retrospective study was to simulate a daily pre-alignment strategy to mitigate systematic positioning errors in image-guided pediatric hadron therapy. All pediatric patients (32 patients, 853 fractions) treated from December 2021 and September 2022 at our Institution were retrospectively considered. For all fractions, daily correction vectors (CVs) resulting from image registration for patient positioning were retrieved in the form of txt files from the hospital database. For each fraction, an adjusted correction vector (V′) was then computed as the difference between the actual one (V) and the algebraic average of the previous ones, as to simulate patient pre-alignment before imaging. The Euclidean norm of each V′ was computed and normalized with respect to that of the corresponding V to derive N. Pre-correcting all the coordinate values led to a 46% average reduction (min 20%, max 60%) in CVs, considering the first 27 fractions (average value in this cohort of patients). Such a potential improvement (N < 1) was observed for the most patients’ fractions (781/853, 91.6%). For the remaining 72/853 cases (8.4%), a remarkable worsening (N > 2) involved only 7/853 (0.82%) fractions. The presented strategy shows promising outcomes in order to ameliorate pediatric patient setup before imaging. However, further investigations to identify patients most likely to benefit from this approach are warranted.