Recently, the spin‐echo full‐intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High‐quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 ± 0.6 Hz at 3T and 12.1 ± 1.0 Hz at 7T for water) and the high signal‐to‐noise ratio (SNR) of the artifact‐free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér‐Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two‐fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7‐fold increase in average SNR (= peak height/root mean square [RMS]‐of‐noise) per unit‐time. Magn Reson Med, 2009.
21 September 2006 in Magnetic Resonance in Medicine
We developed a short‐echo‐time (TE) sequence for proton localized spectroscopy by combining a 1D add‐subtract scheme with a doubly slice‐selective spin‐echo (SE) sequence. The sequence preserves the full magnetization available from the selected volume of interest (VOI). By reducing the number of radiofrequency (RF) pulses acting on transverse magnetization, we were able to minimize the TE to the level that is achievable with the stimulated echo acquisition mode (STEAM) technique, and also gained a twofold increase in sensitivity. The use of an adiabatic pulse in the add‐subtract localization improved the efficiency of excitation in spatially inhomogeneous RF fields, which are frequently encountered at high magnetic fields. The localization performance and sensitivity gains of this method, which is termed SPin ECho, full Intensity Acquired Localized (SPECIAL) spectroscopy, were demonstrated in vivo in rat brains. In conjunction with spectroscopic imaging, a 2‐μl spatial resolution was accomplished with a signal‐to‐noise ratio (SNR) above 30, which is usually sufficient for reliable quantification of a large number of metabolites (neurochemical profile). Magn Reson Med, 2006.
Various proton relaxation times (T2, T1ρ, and gadolinium‐diethylene triamine pentaacetic acid [Gd‐DTPA]‐enhanced T1) were measured in articular cartilage in vitro at 3 T to assess their role in visualizing proteoglycan depletion. Cartilage‐bone specimens were obtained from patients who underwent total joint replacement and got a double dose of Gd‐DTPA 2 hours prior surgery. In these specimens, regions of mechanically undamaged cartilage having a decreased content of proteoglycans showed about 15% lower T1 values compared with apparently normal cartilaginous tissue. The expected increase of the T2 relaxation time was not observed in these regions. On the other hand, the T2 and, to a lower degree, T1 relaxation times were found to be increased in regions of cartilage fibrillation. The T1ρ relaxation times obtained were slightly longer than the corresponding T2 values, but both parameters showed almost identical spatial distributions. J. Magn. Reson. Imaging 1999;10:497–502.