Pingshan Wang

Dr. Pingshan Wang


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YYYang Yang
Yang Yang
HZHanqiao Zhang
Hanqiao Zhang
JZJunjie Zhu
Junjie Zhu
GWGaoyan Wang
Gaoyan Wang
Tzuen-Rong TzengTzuen-Rong Tzeng
Tzuen-Rong Tzeng
PWPingshan Wang
Pingshan Wang
We propose and demonstrate a simple, ultra sensitive radio frequency (RF) sensor to detect a single yeast cell and distinguish its viability in a microfluidic channel. On-chip interference is used to cancel background probing signals to improve sensor sensitivity. Individual viable and nonviable yeast cells (∼ 5.83 ± 0.85 μm in diameter) are measured with clear sensing and identification of these cells.

12 January 2009 in Applied Physics Letters
Verified
Journal Article
Closed access
CSChunrong Song
Chunrong Song
PWPingshan Wang
Pingshan Wang
We demonstrate a sensitive radio frequency (rf) device to detect small dielectric property changes in microfluidic channel. The device consists of an on-chip Wilkinson power divider and a rat-race hybrid, which are built with planar microstrip lines and thin film chip resistors. Interference is used to cancel parasitic background signals. As a result, the measurement sensitivity is improved by more than 20 dB compared with conventional transmission lines. Compared with an ultrasensitive slot antenna/cuvette assembly [K. M. Taylor and D. W. van der Weide, IEEE Trans. Microwave Theory Tech. 53, 1576 (2005)], the proposed rf device is two times more sensitive.

20 November 2014 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
YCYan Cui
Yan Cui
PWPingshan Wang
Pingshan Wang
Dielectric spectroscopy (DS) is an important technique for scientific and technological investigations in various areas. DS sensitivity and operating frequency ranges are critical for many applications, including lab-on-chip development where sample volumes are small with a wide range of dynamic processes to probe. In this work, we present the design and operation considerations of radio-frequency (RF) interferometers that are based on power-dividers (PDs) and quadrature-hybrids (QHs). Such interferometers are proposed to address the sensitivity and frequency tuning challenges of current DS techniques. Verified algorithms together with mathematical models are presented to quantify material properties from scattering parameters for three common transmission line sensing structures, i.e., coplanar waveguides (CPWs), conductor-backed CPWs, and microstrip lines. A high-sensitivity and stable QH-based interferometer is demonstrated by measuring glucose-water solution at a concentration level that is ten times lower than some recent RF sensors while our sample volume is ~ 1 nL. Composition analysis of ternary mixture solutions are also demonstrated with a PD-based interferometer. Further work is needed to address issues like system automation, model improvement at high frequencies, and interferometer scaling.

5 August 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YCYan Cui
Yan Cui
JSJiwei Sun
Jiwei Sun
YHYuxi He
Yuxi He
ZWZheng Wang
Zheng Wang
PWPingshan Wang
Pingshan Wang
We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor (Qeff) of the sensor is as high as ∼3.8 × 106 with 200 μl of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

14 January 2021 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JOJeffrey A. Osterberg
Jeffrey A. Osterberg
NDNeelima Dahal
Neelima Dahal
RDRalu Divan
Ralu Divan
CMChristina S. Miller
Christina S. Miller
DMDavid Moline
David Moline
PWPingshan Wang
Pingshan Wang
We report the development of a simple interferometer-based microwave sensing system for multiple frequency characterization and differentiation of in-flow yeast cells. The interferometer uses a simple microstrip line, integrated with a microfluidic channel, for single-cell measurement. An algorithm was developed and verified with high-frequency structure simulator (HFSS) for complex permittivity, ε*( f ) = ε'( f ) - jε"(f), extraction from measured scattering parameters. The sensing system and the algorithm were evaluated by measuring polystyrene particles of different diameters and at different interferometer operating frequencies. Viable and nonviable Saccharomyces cerevisiae and Saccharomyces pastorianus cells were measured at those frequencies. The results showed frequency-dependent permittivity values for each species of yeast and viability as well as frequency-dependent permittivity differences between different yeast types. The differences at some frequency points are significant and enable the differentiation of cells in mixed suspension, which is also demonstrated with a prediction model developed in this work.

21 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DYDuye Ye
Duye Ye
OMOmkar
Omkar
PWPingshan Wang
Pingshan Wang
This work presents a microwave microfluidic sensor for high performance liquid chromatography (HPLC) applications. The sensor is based on a modified square ring loaded resonator (SRLR), where a transmission line and a ring are electrically shorted with a center gap. A microfluidic channel is bonded above the gap for liquid-under-test (LUT) measurement. When the dielectric constant of LUT is above a threshold value, two degeneration modes of the resonator are separated, resulting in two transmission-zero frequencies. The threshold dielectric constant can be easily tuned by the gap size. High sensitivity is achieved when LUT dielectric constant is close to the threshold value. These features enable the proposed resonator to be optimized for different microfluidic applications. To validate the design, three resonators with $10~\mu \text{m}$ , $30~\mu \text{m}$ and $90~\mu \text{m}$ gap sizes are built and tested with water-methanol solutions in various volume fractions. Additionally, the sensor is connected in series with HPLC system for caffeine and sucrose detection. The detection linearity is characterized by measuring water-caffeine samples from 0.77 ppm to 1000 ppm. A 0.231 ppm limit of detection (LOD) is achieved, revealing a comparable sensitivity with commercial ultraviolet (UV) detectors. The compatibility of the proposed sensor to gradient elution is also demonstrated.