The investigation introduces an advanced model procedure for evaluating the structural reliability of semi-rigid frame connections in existing aged buildings. Specifically, the focus is on the top angle and seat pad (TA–SP) semi-rigid connection, which was not initially considered in the current design standards. The approach employs a plastic hinge model to predict the ultimate strength of the connection and its beam-to-column behaviour. In order to increase computational efficiency, the investigation leverages the nonlinear behaviour of the finite element (FE) model to validate critical parameters. The statistical properties of the existing connection were obtained based on past experimental data, highlighting the weakest elements in the system. The first-order and second-order reliability methods and Monte Carlo simulations were employed to estimate the reliability index. Percentile errors were assessed to understand their impact on higher-order interactions. This new technique of identification quantifies the probability of the system failure interactions. Notably, a 45% lesser error aligns with the target reliability index, while a 114.5% larger error indicates a significant deviation from actual failure probability values. Each methodology introduced adheres to the current standard, and the system reliability analysis provides a vigorous conclusions scheme framework for assessing the existing TA–SP semi-rigid connection.
This investigation introduces an efficient method for assessing the reliability of semi-rigid steel frame connections in existing buildings, explicitly targeting the Top Angle and Seat Pad (TA-SP) semi-rigid connection commonly used in Australian cities' high-rise buildings. The moment capacity of these connections was examined through parameter power model testing, meticulously considering the bending, shear, and prying forces actions to determine the weakest elements in the connection system. A plastic hinge model was applied to ensure computational efficiency and accuracy in assessing the connections' ultimate strength. Comparatively, the finite element (F.E) method M−θ curves were introduced to scrutinise the nonlinear behaviour of the connection, providing validation for the predicted analytical approach. Further emphasis was placed on identifying the reliability of the weakest elements in the connection system, employing the First-Order and Second-Order Reliability Methods models to estimate their reliability index. The correlation between the model's failure probability and a percentile error was also explored, utilising Monte Carlo simulation reference for refined validation. Novel formulas and methodologies were introduced to compute the locked-chain-series system reliability, which accounts for the inherent material and geometric variability. The findings highlight the critical significance of the weakest element in determining the overall reliability of the existing TA-SP connection.