Troy Wanandy

Dr. Troy Wanandy

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2018 in Clinical & Experimental Allergy
Verified
Journal Article
Closed access
PDF file
TWTroy Wanandy
Troy Wanandy
RWRichard Wilson
Richard Wilson
DGDavid Gell
David Gell
HRHayley E. Rose
Hayley E. Rose
NGNuri Gueven
Nuri Gueven
MWMichael D. Wiese
Michael D. Wiese

Verified
Journal Article
Open access
PDF file
DPDiego Jose Lopez Peralta
Diego Jose Lopez Peralta
Ken WinkelKen Winkel
Ken Winkel
TWTroy Wanandy
Troy Wanandy
SNSheryl van Nunen
Sheryl van Nunen
KPKirsten P. Perrett
Kirsten P. Perrett
Adrian LoweAdrian Lowe
Adrian Lowe
Background: The red imported fire ant (RIFA) is one of the world’s most destructive invasive species. RIFA stings are painful and can lead to allergic reactions, including life-threatening anaphylaxis, yet health impacts remain inadequately defined. Methods: We searched MEDLINE (Ovid) and Google Scholar (grey literature) from inception until 20 September 2023 for articles in English using search terms related to red imported fire ants and allergies, including anaphylaxis. Results: Approximately a third of the population in RIFA-infested areas are stung each year. The most frequent reaction is a sterile 1–2 mm pseudo pustule on the skin. Approximately 20% of stings cause a large local reaction and between about 0.5% and 2% stings cause a systemic allergic reaction which can range from skin symptoms to life-threatening anaphylaxis. Local biodiversity is also significantly disrupted by invading RIFA and may lead to complex adverse effects on human health, from agriculture losses to expanded ranges for pathogen vectors. Conclusions: The potential for red imported fire ants to establish themselves as an invasive species in the Western Pacific presents a substantial and costly health issue. Successful eradication and surveillance programs, to identify and eradicate new incursions, would avoid substantial health impacts and costs.

1 June 2021 in Clinical Reviews in Allergy & Immunology
Verified
Journal Article
Closed access
PDF file
TWTroy Wanandy
Troy Wanandy
EMEmily Mulcahy
Emily Mulcahy
WLWun Yee Lau
Wun Yee Lau
SBSimon G. A. Brown
Simon G. A. Brown
MWMichael D. Wiese
Michael D. Wiese

1 August 2019 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
TWTroy Wanandy
Troy Wanandy
YHYoshikazu Honda-Okubo
Yoshikazu Honda-Okubo
NDNoel W. Davies
Noel W. Davies
HRHayley E. Rose
Hayley E. Rose
RHRobert J. Heddle
Robert J. Heddle
MWMichael D. Wiese
Michael D. Wiese

19 October 2023 in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Verified
Journal Article
Closed access
SHSimon A Handley
Simon A Handley
TWTroy Wanandy
Troy Wanandy
LPLouise Prentice
Louise Prentice
Background: Serum copper and zinc are measured to assess deficiency and toxicity. Atomic absorption spectrophotometry and mass spectrometry methods are expensive and require highly trained staff. Colorimetric assays are available from Randox which are inexpensive and can be automated. We validated serum copper and zinc colorimetric assays on the Binding Site Optilite analyser including comparison with flame atomic absorption spectrophotometry (FAAS) and inductively coupled plasma-mass spectrometry (ICP-MS). Methods: Accuracy, imprecision, lower limit of quantitation, and linearity were ascertained. The impact of triglycerides, bilirubin, nickel, and iron on assay performance was also investigated. Comparison of results from colorimetric analysis of patient and external quality assurance samples with those obtained by FAAS and ICP-MS was undertaken. Results: Intra-, and inter-assay imprecision was <9%. Serum copper and zinc assays were linear between 1.8–35.6 and 2.3–45.7 µmol/L, respectively. Agreement was good between colorimetry and FAAS (intercept = -0.7, slope = 1.04) and ICP-MS (intercept = 0.6, slope = 0.99) for serum copper in patients’ samples. For serum zinc, agreement was poor between colorimetry and FAAS (intercept = 2.2, slope = 0.87) and ICP-MS (intercept = 1.9, slope = 0.98) in patients’ samples. There was a poor concordance in assessment of hypozincaemia between colorimetry and FAAS/ICP-MS. Conclusion: The Randox colorimetric assay for serum copper on the Optilite is simple to perform, has a short analysis time, and measured concentrations compare well with FAAS and ICP-MS. Due to poor agreement with FAAS and ICP-MS, colorimetry is not suitable for the measurement of serum zinc.

31 August 2017 in Clinical & Experimental Allergy
Verified
Journal Article
Closed access
PDF file
TWTroy Wanandy
Troy Wanandy
HDH. E. Dwyer
H. E. Dwyer
LML. McLean
L. McLean
NDN. W. Davies
N. W. Davies
David NicholsDavid Nichols
David Nichols
MWM. D. Wiese
M. D. Wiese