Kiran K G Ravindran

Dr. Kiran K G Ravindran

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
KRKiran K G Ravindran
Kiran K G Ravindran
MRM. Ramasubba Reddy
M. Ramasubba Reddy
This study illustrates and evaluates a novel subject-specific target detection framework, sum of squared correlations (SSCOR), for improving the performance in steady-state visual evoked potential (SSVEP) based brain-computer interfaces (BCIs). The SSCOR spatial filter learns a common SSVEP representation space through the optimization of the individual SSVEP templates. The projection onto this SSVEP response subspace improves the signal to noise ratio (SNR) of the SSVEP components embedded in the recorded electroencephalographic (EEG) data. To demonstrate the effectiveness of the proposed framework, the target detection performance of the SSCOR method is compared with the state of the art task-related component analysis (TRCA). The evaluation is conducted on a 40 target SSVEP benchmark data collected from 35 subjects. The results of the extensive comparisons of the performance metrics show that the proposed SSCOR method outperforms the TRCA method. The ensemble version of the SSCOR framework provides an offline simulated information transfer rate (ITR) of 387±9 bits/min which is much higher than that of the ensemble TRCA approach (max. ITR 216±27 bits/min). The significant improvement in the detection accuracy and simulated ITR demonstrates the efficacy of the proposed framework for target detection in SSVEP based BCI applications.

20 July 2023 in SLEEP
Verified
Journal Article
Open access
PDF file
KRKiran K G Ravindran
Kiran K G Ravindran
CMCiro della Monica
Ciro della Monica
GAGiuseppe Atzori
Giuseppe Atzori
DLDamion Lambert
Damion Lambert
HHHana Hassanin
Hana Hassanin
DDDerk-Jan Dijk
Derk-Jan Dijk
To compare the 24-hour sleep assessment capabilities of two contactless sleep technologies (CSTs) to actigraphy in community-dwelling older adults. We collected 7–14 days of data at home from 35 older adults (age: 65–83), some with medical conditions, using Withings Sleep Analyser (WSA, n = 29), Emfit QS (Emfit, n = 17), a standard actigraphy device (Actiwatch Spectrum [AWS, n = 34]), and a sleep diary (n = 35). We compared nocturnal and daytime sleep measures estimated by the CSTs and actigraphy without sleep diary information (AWS-A) against sleep-diary-assisted actigraphy (AWS|SD). Compared to sleep diary, both CSTs accurately determined the timing of nocturnal sleep (intraclass correlation [ICC]: going to bed, getting out of bed, time in bed >0.75), whereas the accuracy of AWS-A was much lower. Compared to AWS|SD, the CSTs overestimated nocturnal total sleep time (WSA: +92.71 ± 81.16 minutes; Emfit: +101.47 ± 75.95 minutes) as did AWS-A (+46.95 ± 67.26 minutes). The CSTs overestimated sleep efficiency (WSA: +9.19% ± 14.26%; Emfit: +9.41% ± 11.05%), whereas AWS-A estimate (−2.38% ± 10.06%) was accurate. About 65% (n = 23) of participants reported daytime naps either in bed or elsewhere. About 90% in-bed nap periods were accurately determined by WSA while Emfit was less accurate. All three devices estimated 24-hour sleep duration with an error of ≈10% compared to the sleep diary. CSTs accurately capture the timing of in-bed nocturnal sleep periods without the need for sleep diary information. However, improvements are needed in assessing parameters such as total sleep time, sleep efficiency, and naps before these CSTs can be fully utilized in field settings.

25 October 2023 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
KRKiran K G Ravindran
Kiran K G Ravindran
CMCiro della Monica
Ciro della Monica
GAGiuseppe Atzori
Giuseppe Atzori
DLDamion Lambert
Damion Lambert
HHHana Hassanin
Hana Hassanin
Derk-Jan 2 DijkDerk-Jan 2 Dijk
Derk-Jan 2 Dijk
Background: Contactless sleep technologies (CSTs) hold promise for longitudinal, unobtrusive sleep monitoring in the community and at scale. They may be particularly useful in older populations wherein sleep disturbance, which may be indicative of the deterioration of physical and mental health, is highly prevalent. However, few CSTs have been evaluated in older people. Objective: This study evaluated the performance of 3 CSTs compared to polysomnography (PSG) and actigraphy in an older population. Methods: Overall, 35 older men and women (age: mean 70.8, SD 4.9 y; women: n=14, 40%), several of whom had comorbidities, including sleep apnea, participated in the study. Sleep was recorded simultaneously using a bedside radar (Somnofy [Vital Things]: n=17), 2 undermattress devices (Withings sleep analyzer [WSA; Withings Inc]: n=35; Emfit-QS [Emfit; Emfit Ltd]: n=17), PSG (n=35), and actigraphy (Actiwatch Spectrum [Philips Respironics]: n=18) during the first night in a 10-hour time-in-bed protocol conducted in a sleep laboratory. The devices were evaluated through performance metrics for summary measures and epoch-by-epoch classification. PSG served as the gold standard. Results: The protocol induced mild sleep disturbance with a mean sleep efficiency (SEFF) of 70.9% (SD 10.4%; range 52.27%-92.60%). All 3 CSTs overestimated the total sleep time (TST; bias: >90 min) and SEFF (bias: >13%) and underestimated wake after sleep onset (bias: >50 min). Sleep onset latency was accurately detected by the bedside radar (bias: 16 min). CSTs did not perform as well as actigraphy in estimating the all-night sleep summary measures. In an epoch-by-epoch concordance analysis, the bedside radar performed better in discriminating sleep versus wake (Matthew correlation coefficient [MCC]: mean 0.63, SD 0.12, 95% CI 0.57-0.69) than the undermattress devices (MCC of WSA: mean 0.41, SD 0.15, 95% CI 0.36-0.46; MCC of Emfit: mean 0.35, SD 0.16, 95% CI 0.26-0.43). The accuracy of identifying rapid eye movement and light sleep was poor across all CSTs, whereas deep sleep (ie, slow wave sleep) was predicted with moderate accuracy (MCC: >0.45) by both Somnofy and WSA. The deep sleep duration estimates of Somnofy correlated (r2=0.60; P<.01) with electroencephalography slow wave activity (0.75-4.5 Hz) derived from PSG, whereas for the undermattress devices, this correlation was not significant (WSA: r2=0.0096, P=.58; Emfit: r2=0.11, P=.21). Conclusions: These CSTs overestimated the TST, and sleep stage prediction was unsatisfactory in this group of older people in whom SEFF was relatively low. Although it was previously shown that CSTs provide useful information on bed occupancy, which may be useful for particular use cases, the performance of these CSTs with respect to the TST and sleep stage estimation requires improvement before they can serve as an alternative to PSG in estimating most sleep variables in older individuals.

10 March 2022 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
POPaula de Oliveira
Paula de Oliveira
CCClaire Cella
Claire Cella
NLNicolas Locker
Nicolas Locker
KRKiran K G Ravindran
Kiran K G Ravindran
AMAgampodi Mendis
Agampodi Mendis
RWRaphaelle Winsky-Sommerer
Raphaelle Winsky-Sommerer
Several cellular pathways contribute to neurodegenerative tauopathy-related disorders. Microglial activation, a major component of neuroinflammation, is an early pathologic hallmark that correlates with cognitive decline, while the unfolded protein response (UPR) contributes to synaptic pathology. Sleep disturbances are prevalent in tauopathies and may also contribute to disease progression. Few studies have investigated whether manipulations of sleep influence cellular pathologic and behavioral features of tauopathy. We investigated whether trazodone, a licensed antidepressant with hypnotic efficacy in dementia, can reduce disease-related cellular pathways and improve memory and sleep in male rTg4510 mice with a tauopathy-like phenotype. In a 9 week dosing regimen, trazodone decreased microglial NLRP3 inflammasome expression and phosphorylated p38 mitogen-activated protein kinase levels, which correlated with the NLRP3 inflammasome, the UPR effector ATF4, and total tau levels. Trazodone reduced theta oscillations during rapid eye movement (REM) sleep and enhanced REM sleep duration. Olfactory memory transiently improved, and memory performance correlated with REM sleep duration and theta oscillations. These findings on the effects of trazodone on the NLRP3 inflammasome, the unfolded protein response and behavioral hallmarks of dementia warrant further studies on the therapeutic value of sleep-modulating compounds for tauopathies.SIGNIFICANCE STATEMENTDementia and associated behavioral symptoms such as memory loss and sleep disturbance are debilitating. Identifying treatments that alleviate symptoms and concurrently target cellular pathways contributing to disease progression is paramount for the patients and their caregivers. Here we show that a chronic treatment with trazodone, an antidepressant with positive effects on sleep, has beneficial effects on several cellular pathways contributing to neuroinflammation and tau pathology, in tauopathy-like rTg4510 mice. Trazodone also improved rapid eye movement (REM) sleep, the slowing of brain oscillations, and olfactory memory disturbances, which are all early symptoms observed in Alzheimer's disease. Thus, trazodone and compounds with REM sleep-promoting properties may represent a promising treatment approach to reduce the early symptoms of tauopathy and slow down disease progression.

27 August 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
KRKiran K G Ravindran
Kiran K G Ravindran
CMCiro della Monica
Ciro della Monica
GAGiuseppe Atzori
Giuseppe Atzori
DLDamion Lambert
Damion Lambert
HHHana Hassanin
Hana Hassanin
Derk-Jan 2 DijkDerk-Jan 2 Dijk
Derk-Jan 2 Dijk
Background: Longitudinal monitoring of vital signs provides a method for identifying changes to general health in an individual, particularly in older adults. The nocturnal sleep period provides a convenient opportunity to assess vital signs. Contactless technologies that can be embedded into the bedroom environment are unintrusive and burdenless and have the potential to enable seamless monitoring of vital signs. To realize this potential, these technologies need to be evaluated against gold standard measures and in relevant populations. Objective: We aimed to evaluate the accuracy of heart rate and breathing rate measurements of 3 contactless technologies (2 undermattress trackers, Withings Sleep Analyzer [WSA] and Emfit QS [Emfit]; and a bedside radar, Somnofy) in a sleep laboratory environment and assess their potential to capture vital signs in a real-world setting. Methods: Data were collected from 35 community-dwelling older adults aged between 65 and 83 (mean 70.8, SD 4.9) years (men: n=21, 60%) during a 1-night clinical polysomnography (PSG) test in a sleep laboratory, preceded by 7 to 14 days of data collection at home. Several of the participants (20/35, 57%) had health conditions, including type 2 diabetes, hypertension, obesity, and arthritis, and 49% (17) had moderate to severe sleep apnea, while 29% (n=10) had periodic leg movement disorder. The undermattress trackers provided estimates of both heart rate and breathing rate, while the bedside radar provided only the breathing rate. The accuracy of the heart rate and breathing rate estimated by the devices was compared with PSG electrocardiogram-derived heart rate (beats per minute) and respiratory inductance plethysmography thorax-derived breathing rate (cycles per minute), respectively. We also evaluated breathing disturbance indexes of snoring and the apnea-hypopnea index, available from the WSA. Results: All 3 contactless technologies provided acceptable accuracy in estimating heart rate (mean absolute error <2.12 beats per minute and mean absolute percentage error <5%) and breathing rate (mean absolute error ≤1.6 cycles per minute and mean absolute percentage error <12%) at 1-minute resolution. All 3 contactless technologies were able to capture changes in heart rate and breathing rate across the sleep period. The WSA snoring and breathing disturbance estimates were also accurate compared with PSG estimates (WSA snore: r2=0.76; P<.001; WSA apnea-hypopnea index: r2=0.59; P<.001). Conclusions: Contactless technologies offer an unintrusive alternative to conventional wearable technologies for reliable monitoring of heart rate, breathing rate, and sleep apnea in community-dwelling older adults at scale. They enable the assessment of night-to-night variation in these vital signs, which may allow the identification of acute changes in health, and longitudinal monitoring, which may provide insight into health trajectories. International Registered Report Identifier (IRRID): RR2-10.3390/clockssleep6010010

4 May 2025 in SLEEP
Verified
Journal Article
Closed access
KRKiran K G Ravindran
Kiran K G Ravindran
CMCiro della Monica
Ciro della Monica
GAGiuseppe Atzori
Giuseppe Atzori
RNRamin Nilforooshan
Ramin Nilforooshan
HHHana Hassanin
Hana Hassanin
Derk-Jan 2 DijkDerk-Jan 2 Dijk
Derk-Jan 2 Dijk
Study objectives: Portable electroencephalography (EEG) devices offer the potential for accurate quantification of sleep at home but have not been evaluated in relevant populations. We assessed the Dreem headband (DHB) and its automated sleep staging algorithm in 62 older adults [age (mean ± SD) 70.5 ± 6.7 years; 12 Alzheimer’s disease]. Methods: The accuracy of sleep measures, epoch-by-epoch staging, and the quality of EEG signals for quantitative EEG (qEEG) analysis were compared to standard polysomnography (PSG) in a sleep laboratory. Results: The DHB algorithm accurately estimated total sleep time (TST) and sleep efficiency (SEFF) with a symmetric mean absolute percentage error (SMAPE) < 10%. Wake after sleep onset (WASO) and number of awakenings (NAW) were underestimated (WASO: ~17 minutes; NAW: ~9 counts) with SMAPE < 20%. Sleep onset latency (SOL) was overestimated by ~30 minutes when using the entire DHB recording period, but it was accurate (bias: 0.3 minutes) when estimated over the lights-off period. Stage N3 and total non-rapid eye movement (NREM) sleep durations were estimated accurately (bias < 20 minutes), while REM sleep was overestimated (~25 minutes; SMAPE: ~24%). Epoch-by-epoch sleep/wake classification showed acceptable performance (MCC = 0.77 ± 0.17) and five-stage sleep classification was moderate (MCC = 0.54 ± 0.14). After artifact removal, 73% of the recordings were usable for qEEG analysis. Concordance (p < 0.001) of EEG band power ranged from moderate to good: slow-wave activity r2 = 0.57; theta r2 = 0.56; alpha r2 = 0.65; sigma power r2 = 0.34. Conclusions: DHB algorithm provides accurate estimates of several sleep measures and qEEG metrics. However, further improvement in REM detection is needed to enhance its utility for research and clinical applications.