Mauro Henrique Agapito Da Silva

Dr. Mauro Henrique Agapito Da Silva

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in Arquivos Brasileiros de Cardiologia
Verified
Journal Article
Open access
PDF file
LFLucas Leal Fraga
Lucas Leal Fraga
BNBruno Ramos Nascimento
Bruno Ramos Nascimento
BHBeatriz Costa Haiashi
Beatriz Costa Haiashi
AFAlexandre Melo Ferreira
Alexandre Melo Ferreira
MSMauro Henrique Agapito Da Silva
Mauro Henrique Agapito Da Silva
CCClareci Cardoso
Clareci Cardoso
Resumo Fundamento: As ferramentas de telecardiologia são estratégias valiosas para melhorar a estratificação de risco. Objetivo: Objetivamos avaliar a acurácia da tele-eletrocardiografia (ECG) para predizer anormalidades no ecocardiograma de rastreamento na atenção primária. Métodos: Em 17 meses, 6 profissionais de saúde em 16 unidades de atenção primária foram treinados em protocolos simplificados de ecocardiografia portátil. Tele-ECGs foram registrados para diagnóstico final por um cardiologista. Pacientes consentidos com anormalidades maiores no ECG pelo código de Minnesota e uma amostra 1:5 de [...] Resumo Fundamento: As ferramentas de telecardiologia são estratégias valiosas para melhorar a estratificação de risco. Objetivo: Objetivamos avaliar a acurácia da tele-eletrocardiografia (ECG) para predizer anormalidades no ecocardiograma de rastreamento na atenção primária. Métodos: Em 17 meses, 6 profissionais de saúde em 16 unidades de atenção primária foram treinados em protocolos simplificados de ecocardiografia portátil. Tele-ECGs foram registrados para diagnóstico final por um cardiologista. Pacientes consentidos com anormalidades maiores no ECG pelo código de Minnesota e uma amostra 1:5 de

11 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MDMarina G. Diniz
Marina G. Diniz
LFLucas L. Fraga
Lucas L. Fraga
MNMaria Carmo Pereira Nunes
Maria Carmo Pereira Nunes
KOKaciane K. B. Oliveira
Kaciane K. B. Oliveira
IAIngred Beatriz Amaral
Ingred Beatriz Amaral
BNBruno Ramos Nascimento
Bruno Ramos Nascimento
Introduction: Handheld echocardiography (echo) is the tool of choice for rheumatic heart disease (RHD) screening. We aimed to assess the agreement between screening and standard echo for latent RHD diagnosis in schoolchildren from an endemic setting. Methods: Over 14 months, 3 nonphysicians used handheld machines and the 2012 WHF Criteria to determine RHD prevalence in consented schoolchildren from Brazilian low-income public schools. Studies were interpreted by telemedicine by 3 experts (Brazil, US). RHD-positive children (borderline/definite) and those with congenital heart disease (CHD) were referred for standard echo, acquired and interpreted by a cardiologist. Agreement between screening and standard echo, by WHF subgroups, was assessed. Results: 1390 students were screened in 6 schools, with 110 (7.9%, 95% CI 6.5–9.5) being screen positive (14 ± 2 years, 72% women). Among 16 cases initially diagnosed as definite RHD, 11 (69%) were confirmed, 4 (25%) reclassified to borderline, and 1 to normal. Among 79 cases flagged as borderline RHD, 19 (24%) were confirmed, 50 (63%) reclassified to normal, 8 (10%) reclassified as definite RHD, and 2 had mild CHD. Considering the 4 diagnostic categories, kappa was 0.18. In patients with borderline RHD reclassified to non-RHD, the most frequent WHF criterion was B (isolated mitral regurgitation, 64%), followed by A (2 mitral valve morphological features, 31%). In 1 patient with definite RHD reclassified to normal, the WHF criterion was D (borderline RHD in aortic and mitral valves). After standard echo, RHD prevalence was 3.2% (95% CI 2.3–4.2). Conclusions: Although practical, RHD screening with handheld devices tends to overestimate prevalence.

1 October 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
DFD A Santos Ferreira
D A Santos Ferreira
IFI Fernandes
I Fernandes
SDS Diaz
S Diaz
FSFrancisca Saraiva
Francisca Saraiva
CGClaudio Guerreiro
Claudio Guerreiro
RFR Fontes-Carvalho
R Fontes-Carvalho
Low-flow status, currently defined as a stroke volume index (SVi) <35 mL/m2, is an important prognostic predictor for mortality after Transcatheter Aortic Valve Implantation (TAVI) for severe aortic stenosis (SAS). However, transaortic flow rate (FR) – defined as stroke volume divided by left ventricle ejection time - has recently been suggested to be superior to SVi in defining low-flow states, as it reflects more closely valvular resistance, while being independent of body surface area. Low FR is most consistently defined as FR<200 mL/s. Determine the prognostic impact of FR and SVi before TAVI in survival after intervention for SAS. A single-centre retrospective database of all TAVI performed between 2011 and 2019 was analyzed, and cases with pre-intervention echocardiograms available were included. Low-flow patients were identified according to basal FR (<200 mL/s) or SVi (<35 mL/m2), and compared with normal-flow cases. The primary endpoint was defined as time to all-cause death or last follow-up. The impact of flow-status (using FR or SVi) in survival was assessed using Kaplan-Meier curves and log-rank test, as well as Cox proportional hazard model adjusted for EuroSCORE II, using FR or SVi either as categorical or continuous variables. A subanalysis further compared patients with preserved and reduced ejection fraction (EF, <52%). p<0.05 was considered statistically significant. From 657 TAVI performed, 490 (74.6%) cases were included, with a median follow-up of 43 months. From those, 59.6% were defined as low-flow according to FR, and 43.3% using SVi. Low-flow patients, using each parameter, were of higher surgical risk (EuroSCORE II and STS scores), had more advanced NYHA classes, worse estimated creatinine clearance, and suffered more frequently from coronary artery disease. Low-FR patients were also older, and more predominantly female. Atrial fibrillation was more prevalent among low SVi cases. Functional aortic valve area was lower in low-flow patients using both assessments, but low-SVi was also associated with lower transaortic gradients, as well as lower EF before and after TAVI. Regarding all-cause mortality, low-SVi was associated with worse survival [p=0.02, hazard ratio (HR) 1.43 (1.05–1.94)], but not low-FR (p=0.4). However, low-SVi, when adjusted for EuroScore II, was no longer a predictor of all-cause mortality (p=0.08). When considering FR and SVi as continuous variables, a higher SVi (but not FR) was associated with better survival (HR 0.98, p=0.047) in multivariable analysis adjusted for EuroSCORE II. When stratifying according to preserved and reduced EF, both FR and SVi did not predict all-cause mortality. Low-flow states are common in SAS population treated with TAVI, being frequently associated with worse symptoms and higher procedural risk. Low-SVi, but not low-FR, negatively impacts survival after intervention, representing a marker for prognosis after TAVI. Type of funding sources: None. Patients' characteristics by flow status Kaplan-Meier curves by flow status

1 January 2020
Verified
Conference Paper
Closed access
TATaílly De Souza Almeida
Taílly De Souza Almeida
HBHelena Guimarães Dias Barbosa
Helena Guimarães Dias Barbosa
PSPedro Fernandes dos Santos
Pedro Fernandes dos Santos
LSLucas Teles de Carvalho Godoy Sampaio
Lucas Teles de Carvalho Godoy Sampaio
MSMauro Henrique Agapito Da Silva
Mauro Henrique Agapito Da Silva
LDLilian Martins Oliveira Diniz
Lilian Martins Oliveira Diniz
Caderno de Anais do I Congresso de Medicina de Emergência da Liga Acadêmica de Medicina de Urgência e Emergência (LAMUE) (978-65-88243-25-1) - Análise Comparativa Entre A Eficácia Da Reanimação Cardiopulmonar Mecânica E Compressões Manuais De Alta Qualidade Em Atendimentos Extra-Hospitalares: Revisão De Literatura