Amit Goyal

Dr. Amit Goyal

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2006 in JNCI: Journal of the National Cancer Institute
Verified
Journal Article
Open access
PDF file
RMRobert E. Mansel
Robert E. Mansel
LFLesley Fallowfield
Lesley Fallowfield
MKMark Kissin
Mark Kissin
AGAmit Goyal
Amit Goyal
RNRobert G. Newcombe
Robert G. Newcombe
PEPeter J. Ell
Peter J. Ell
Background: Sentinel lymph node biopsy in women with operable breast cancer is routinely used in some countries for staging the axilla despite limited data from randomized trials on morbidity and mortality outcomes. We conducted a multicenter randomized trial to compare quality-of-life outcomes between patients with clinically node-negative invasive breast cancer who received sentinel lymph node biopsy and patients who received standard axillary treatment. Methods: The primary outcome measures were arm and shoulder morbidity and quality of life. From November 1999 to October 2003, 1031 patients were randomly assigned to undergo sentinel lymph node biopsy (n = 515) or standard axillary surgery (n = 516). Patients with sentinel lymph node metastases proceeded to delayed axillary clearance or received axillary radiotherapy (depending on the protocol at the treating institution). Intention-to-treat analyses of data at 1, 3, 6, and 12 months after surgery are presented. All statistical tests were two-sided. Results: The relative risks of any lymphedema and sensory loss for the sentinel lymph node biopsy group compared with the standard axillary treatment group at 12 months were 0.37 (95% confidence interval [CI] = 0.23 to 0.60; absolute rates: 5% versus 13%) and 0.37 (95% CI = 0.27 to 0.50; absolute rates: 11% versus 31%), respectively. Drain usage, length of hospital stay, and time to resumption of normal day-to-day activities after surgery were statistically significantly lower in the sentinel lymph node biopsy group (all P <.001), and axillary operative time was reduced ( P = .055). Overall patient-recorded quality of life and arm functioning scores were statistically significantly better in the sentinel lymph node biopsy group throughout (all P ≤.003). These benefits were seen with no increase in anxiety levels in the sentinel lymph node biopsy group ( P >.05). Conclusion: Sentinel lymph node biopsy is associated with reduced arm morbidity and better quality of life than standard axillary treatment and should be the treatment of choice for patients who have early-stage breast cancer with clinically negative nodes.

19 April 2005 in Annals of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
Tracey MartinTracey Martin
Tracey Martin
AGAmit Goyal
Amit Goyal
GWGareth Watkins
Gareth Watkins
Wen G. JiangWen G. Jiang
Wen G. Jiang

16 March 2006 in Breast Cancer Research and Treatment
Verified
Journal Article
Open access
PDF file
AGAmit Goyal
Amit Goyal
RNRobert G Newcombe
Robert G Newcombe
ACAlok Chhabra
Alok Chhabra
RMRobert E Mansel
Robert E Mansel
OGon behalf of the ALMANAC Trialists Group
on behalf of the ALMANAC Trialists Group
Despite the widespread application of sentinel lymph node biopsy (SLNB) for early stage breast cancer, there is a wide variation in reported test performance characteristics. A major aim of this prospective multicentre validation study was to quantify detection and false-negative rates of SLNB and evaluate factors influencing them. Eight-hundred and fourty-two patients with clinically node-negative breast cancer underwent SLNB according to a standardised protocol that used a combination of radiopharmaceutical 99mTc-albumin colloid and Patent Blue V dye. SLNB was followed by standard axillary treatment at the same operation in all patients. Sentinel lymph nodes (SLNs) were identified in 803 (96.1%) of 836 evaluable cases. The median number of SLNs removed per patient was 2 (range 1–9). There were 19 false negatives, resulting in a sensitivity of 263/282 (93.3%) and accuracy 782/803 (97.6%). SLNs were successfully identified by blue dye in 698 (85.6%), by isotope in 698 (85.6%), and by the combination of blue dye and isotope in 782 (96.0%) of 815 patients. Among 276 node positive patients, one or more positive SLNs were identified by blue dye in 251 (90.9%), by isotope in 246 (89.1%) and by the combination of blue dye and gamma probe in 258 (93.5%). Obesity, tumor location other than upper outer quadrant and non-visualisation of SLNs on the pre-operative lymphoscintiscan were significantly associated with failed localisation (p<0.001, p=0.008, p<0.001, respectively). The false-negative rate in patients with grade 3 tumors was 9.6%, compared with 4.7% in those with grade 2 tumors (p=0.022). The false-negative rate in patients who had one SLN harvested was 10.1%, compared with 1.1% in those who had multiple SLNs (three or more) removed (p=0.010). SLNB can accurately determine whether axillary metastases are present in patients with early stage breast cancer with clinically negative axillary nodes. Both success and accuracy of SLNB are optimised by the combined use of blue dye and isotope. SLNB success decreases with increasing body mass, tumor location other than the upper outer quadrant and non-visualisation of hot nodes on the pre-operative lymphoscintiscan. This study demonstrates reduction in the predictive value of a negative SLNB in grade 3 tumors.

1 April 2010 in European Journal of Surgical Oncology
Verified
Journal Article
Closed access
LBL. Barthelmes
L. Barthelmes
AGAmit Goyal
Amit Goyal
RNR.G. Newcombe
R.G. Newcombe
FMF. McNeill
F. McNeill
RMR.E. Mansel
R.E. Mansel

1 December 2015 in Clinical Oncology
Verified
Journal Article
Closed access
AGAmit Goyal
Amit Goyal
DDD. Dodwell
D. Dodwell

16 February 2018 in Breast Cancer Research and Treatment
Verified
Journal Article
Open access
PDF file
JHJames R. Harvey
James R. Harvey
YLYit Lim
Yit Lim
JMJohn Murphy
John Murphy
MHMiles Howe
Miles Howe
JMJulie Morris
Julie Morris
AMAnthony Maxwell
Anthony Maxwell
Purpose Wire localization has several disadvantages, notably wire migration and difficulty scheduling the procedure close to surgery. Radioactive seed localization overcomes these disadvantages, but implementation is limited due to radiation safety requirements. Magnetic seeds potentially offer the logistical benefits and transcutaneous detection equivalence of a radioactive seed, with easier implementation. This study was designed to evaluate the feasibility and safety of using magnetic seeds for breast lesion localization. Methods A two-centre open-label cohort study to assess the feasibility and safety of magnetic seed (Magseed) localization of breast lesions. Magseeds were placed under radiological guidance into women having total mastectomy surgery. The primary outcome measure was seed migration distance. Secondary outcome measures included accuracy of placement, ease of transcutaneous detection, seed integrity and safety. Results Twenty-nine Magseeds were placed into the breasts of 28 patients under ultrasound guidance. There was no migration of the seeds between placement and surgery. Twenty-seven seeds were placed directly in the target lesion with the other seeds being 2 and 3 mm away. All seeds were detectable transcutaneously in all breast sizes and at all depths. There were no complications or safety issues. Conclusions Magnetic seeds are a feasible and safe method of breast lesion localization. They can be accurately placed, demonstrate no migration in this feasibility study and are detectable in all sizes and depths of breast tissue. Now that safety and feasibility have been demonstrated, further clinical studies are required to evaluate the seed’s effectiveness in wide local excision surgery.