Peter Theobald

Dr. Peter Theobald

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2006 in Journal of Anatomy
Verified
Journal Article
Closed access
PDF file
PTPeter Theobald
Peter Theobald
GBG. Bydder
G. Bydder
CDC. Dent
C. Dent
LNL. Nokes
L. Nokes
NPN. Pugh
N. Pugh
MBM. Benjamin
M. Benjamin

1 November 2005 in Injury
Verified
Journal Article
Closed access
PTPeter Theobald
Peter Theobald
MBM. Benjamin
M. Benjamin
LNL. Nokes
L. Nokes
NPN. Pugh
N. Pugh

1 February 2012 in Manual Therapy
Verified
Journal Article
Closed access
PTPeter Theobald
Peter Theobald
MJMichael D. Jones
Michael D. Jones
JWJonathan Mark Williams
Jonathan Mark Williams

1 August 2013 in Resuscitation
Verified
Journal Article
Closed access
PMPhilip Martin
Philip Martin
PTPeter Theobald
Peter Theobald
AKAlison Kemp
Alison Kemp
SMSabine Maguire
Sabine Maguire
IMIan Maconochie
Ian Maconochie
MJMichael Jones
Michael Jones

28 November 2012 in Archives of Disease in Childhood
Verified
Journal Article
Closed access
PDF file
PMPhilip Stephen Martin
Philip Stephen Martin
AKAlison Mary Kemp
Alison Mary Kemp
PTPeter Theobald
Peter Theobald
SMS. A. Maguire
S. A. Maguire
MJMichael D Jones
Michael D Jones
Background Morbidity and mortality remain high following infant cardiac arrest. Optimal cardiopulmonary resuscitation (CPR) is therefore imperative. Objective Comparison of two-thumb (TT) and two-finger (TF) infant chest compression technique compliance with international recommendations. Design Randomised cross-over experimental study. Methods Twenty-two certified Advanced Paediatric Life Support (APLS) instructors performed 2 min continuous TT and TF chest compressions on an instrumented infant CPR manikin. Compression depth (CD), release force (RF), compression rate (CR) and duty cycles (DCs) were recorded. Quality indices were developed to calculate the proportion of compressions that complied with internationally recommended targets, and an overall quality index was used to calculate the proportion that complied with all four targets. Results Mean CD was 33 mm and 26 mm (p<0.001; target ≥36.7 mm), mean RF was 0.8 kg and 0.2 kg (p<0.001; target <2.5 kg), mean CR was 128/min and 131/min (p=0.052; target 100–120/min) and mean DCs was 61% and 53% (p<0.001; target 30–50%) for the TT and TF techniques, respectively. With the exception of RF, the majority of compressions failed to comply with targets. The TT technique improved median CD compliance (6% vs 0% (p<0.001)), while the TF technique improved median DC compliance (23% vs 0% (p<0.001)). Overall compliance with all four targets was <1% for both techniques (p=0.14). Conclusions Compliance of APLS instructors with current international recommendations during simulated infant CPR is poor. The TT technique provided improved CD compliance, while the TF technique provided superior DC compliance. If this reflects current clinical practice, optimisation of performance to achieve international recommendations during infant CPR is called for.

1 February 2013 in Biomaterials
Verified
Journal Article
Open access
IKIlyas M. Khan
Ilyas M. Khan
LFLewis Francis
Lewis Francis
PTPeter Theobald
Peter Theobald
SPStefano Perni
Stefano Perni
RYRobert D. Young
Robert D. Young
CACharles W. Archer
Charles W. Archer
Articular cartilage maturation is the postnatal development process that adapts joint surfaces to their site-specific biomechanical demands. Maturation involves gross morphological changes that occur through a process of synchronised growth and resorption of cartilage and generally ends at sexual maturity. The inability to induce maturation in biomaterial constructs designed for cartilage repair has been cited as a major cause for their failure in producing persistent cell-based repair of joint lesions. The combination of growth factors FGF2 and TGFβ1 induces accelerated articular cartilage maturation in vitro such that many molecular and morphological characteristics of tissue maturation are observable. We hypothesised that experimental growth factor-induced maturation of immature cartilage would result in a biophysical and biochemical composition consistent with a mature phenotype. Using native immature and mature cartilage as reference, we observed that growth factor-treated immature cartilages displayed increased nano-compressive stiffness, decreased surface adhesion, decreased water content, increased collagen content and smoother surfaces, correlating with a convergence to the mature cartilage phenotype. Furthermore, increased gene expression of surface structural protein collagen type I in growth factor-treated explants compared to reference cartilages demonstrates that they are still in the dynamic phase of the postnatal developmental transition. These data provide a basis for understanding the regulation of postnatal maturation of articular cartilage and the application of growth factor-induced maturation in vitro and in vivo in order to repair and regenerate cartilage defects.