Kun Wang

Dr. Kun Wang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2025 in Emergency Radiology
Verified
Journal Article
Open access
PDF file
QZQiuhua Zhang
Qiuhua Zhang
KWKun Wang
Kun Wang
HRHong Ren
Hong Ren
Background: The triple rule-out computed tomography angiography (TRO-CTA) has recently emerged as a technique that noninvasively evaluates the coronary arteries (CAs), the pulmonary arteries (PAs) and the thoracic aorta (TA). Objective: To evaluate the feasibility of an optimized scanning protocol to reduce the volume of iodine contrast media (ICM), injection rate, and radiation dose in patients undergoing TRO-CTA. Methods: Patients undergoing TRO-CTA were assigned to either group A or group B using a 16 cm wide-detector CT. Patients in group A were imaged with a traditional triple scanning protocol with a sequence of the PA, CAs, and TA. Patients in group B were imaged using the modified protocol with scanning sequence of PA, TA, and CAs, ICM of 55 ml, and injection rate of 4.5 mL/s. The image quality and effective radiation dose (ED) were compared. Results: There were no significant differences in basic information between groups A and B. Other than the left PA, RA, and RV, there were no significant differences in the CT attenuation values of relevant vascular structures between groups A and B. There were no significant differences in CNR values between the two groups except the LAD-D and LCX. The image quality scores were comparable between groups A and B except the CAs. However, there were significant differences between the two groups in ICM (p < 0.05), scanning time (p < 0.001) and ED (p = 0. 023). Conclusions: The optimized TRO-CTA scanning protocol can achieve less ICM and lower ED while maintaining image quality.

7 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
KWKun Wang
Kun Wang
ASAiyun Sun
Aiyun Sun
XQXia Qiu
Xia Qiu
CWChunqiao Wu
Chunqiao Wu
HRHong Ren
Hong Ren
YZYueqiao Zhang
Yueqiao Zhang
Background/Objectives: Dedicated coronary CT angiography (CCTA) without physical electrocardiographic gating may simplify acquisition, but segment-level interpretability may vary across the coronary tree. We evaluated coronary segment evaluability and factors associated with non-evaluability on dedicated non-ECG-gated CCTA. Methods: This retrospective single-center study included 320 patients and 3739 anatomically present coronary segments with a reference diameter of at least 1.5 mm. Evaluability required confident classification of diameter stenosis as <50% or ≥50%. Segment calcification was graded separately using a prespecified visual scale as none, mild, moderate, or severe. Patient-clustered generalized estimating equations used a binomial distribution, logit link, exchangeable working correlation, and robust standard errors. Results: Overall, 3378 segments (90.3%) were evaluable. All included segments were evaluable in 118/320 patients (36.9%); 202/320 (63.1%) had at least one non-evaluable segment and 111/320 (34.7%) had at least one proximal/mid non-evaluable segment. Examination success was 320/336 (95.2%). When 182 observed eligible segments from the 16 globally non-diagnostic examinations were included as non-evaluable, segment evaluability was 3378/3921 (86.2%); an additional 18-segment worst-case boundary yielded 3378/4027 (83.9%). Evaluability declined from 93.4% without calcification to 88.8%, 84.3%, and 74.3% with mild, moderate, and severe calcification. Adjusted odds ratios for non-evaluability were 1.95 (95% CI, 1.46–2.60), 3.13 (2.18–4.49), and 6.53 (4.39–9.71), respectively, versus no calcification. Higher heart rate (per 10 beats/min: OR, 1.52; 95% CI, 1.36–1.69) and right coronary artery location (OR, 1.56; 95% CI, 1.20–2.02) were associated with non-evaluability, whereas larger reference diameter was associated with lower odds (per 1 mm: OR, 0.69; 95% CI, 0.53–0.89). Conclusions: Most included coronary segments were evaluable on dedicated non-ECG-gated CCTA, but interpretability varied with calcification, heart rate, vessel territory, and caliber. These findings characterize segment-level feasibility and do not establish diagnostic accuracy, equivalence to ECG-gated CCTA, or a clinical eligibility threshold.