Xiu-Ting Wei

Xiu-Ting Wei


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
CGChao Gao
Chao Gao
SZShuai Zhang
Shuai Zhang
XWXiu-Ting Wei
Xiu-Ting Wei
Bin ZhouBin Zhou
Bin Zhou
DGDong Guo
Dong Guo
HLHaowen Li
Haowen Li
In order to address the challenge of achieving optimal prediction accuracy when a single prediction model faced with changes in meteorological conditions of different weather types, this paper proposes a photovoltaic (PV) power prediction method based on the combination of similar day clustering and convolutional neural network (CNN)-gated recurrent unit (GRU). The Pearson correlation coefficient and Spearman’s correlation coefficient are used to filter out the key features such as total solar radiation and module temperature to construct a new input dataset; the K-means algorithm is used to perform clustering analysis on the data, and the data are classified into sunny, cloudy, and rainy days; the spatial correlation features of the meteorological factors are extracted by using the convolutional neural network (CNN), and the CNN-GRU model is established by combining with the gated recurrent units (GRUs). The PV output power is predicted based on the PV power data and the corresponding meteorological data from a place in Ningxia, collected during June to August 2020, and the method proposed in the article is tested. Validation results show that, compared to other models, the model proposed in this paper reduces MAE and RMSE by 66.1% and 65.7% on average under three different weather type scenarios, and improves R2 by 19.8% on average. This verifies that the model has high prediction accuracy and generalization ability, achieving better results in PV output power prediction. The CNN-GRU model demonstrates superior capability in modeling short- and long-term dependencies compared to other deep learning hybrid approaches, while also achieving higher computational efficiency and faster training convergence.

16 January 2023 in Machines
Verified
Journal Article
Open access
PDF file
CLChuan Liu
Chuan Liu
XWXiuting Wei
Xiuting Wei
ZYZuyao Yi
Zuyao Yi
XWXiu-Ting Wei
Xiu-Ting Wei
CZChanghao Zhu
Changhao Zhu
ZMZe Ma
Ze Ma
The opposed-power reciprocating pump has the characteristics of high pressure, large flow, and high efficiency and energy saving. However, due to the special structure of the opposed-power reciprocating pump, existing theoretical methods cannot analyze its dynamic performance. Therefore, this paper proposes a method of analyzing the power end of the opposed-power reciprocating pump. Firstly, according to the working principle and structural characteristics of the traditional plunger pump, the novel and complex structure of the opposed-power reciprocating pump is analyzed by analogy, and the force analysis model of the crankshaft is established. The dynamic analysis model of the Matlab program is used to solve the dynamic load and section stress in the working process, and the variation law of crankshaft load is obtained. The 25 most critical working conditions are selected for analysis, and the most critical station and section of the crankshaft are obtained. With the connection between ANSYS Workbench and Solidworks, the model is imported into ANSYS Workbench, the load on the crank pin is loaded by APDL command flow, and the static analysis of the crankshaft is carried out to obtain the stress and strain of the crankshaft. Finally, the static and fatigue strength of the dangerous section is checked, and it is proven that the strength and stiffness of the crankshaft meet the design requirements. The results show that the dynamic analysis results of the crankshaft under critical working conditions are consistent with the finite element analysis, verifying the rationality of the method and providing a reference for the improvement and optimized design of the crankshaft of the opposed-power reciprocating pump.

12 March 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
SZShuai Zhang
Shuai Zhang
DGDong Guo
Dong Guo
Bin ZhouBin Zhou
Bin Zhou
YWYuqiong Wang
Yuqiong Wang
XWXiu-Ting Wei
Xiu-Ting Wei
PMPengcheng Ma
Pengcheng Ma
As the adoption of electric vehicles (EVs) continues to rise, the pressure on charging station resources has intensified, particularly under high-load conditions, where limited charging infrastructure struggles to meet the growing demand. Issues such as uneven resource allocation, prolonged charging wait times, fairness concerns among different user groups, and inefficient scheduling strategies have significantly impacted the overall operational efficiency of charging infrastructure and the user experience. Against this backdrop, the effective management of charging infrastructure has become increasingly critical, especially in balancing the diverse mobility needs and service expectations of users. Traditional charging scheduling methods often rely on static or rule-based strategies, which lack the flexibility to adapt to dynamic load environments. This rigidity hinders optimal resource allocation, leading to low charging pile utilization and reduced charging efficiency for users. To address this, we propose an Adaptive Charging Priority (ACP) strategy aimed at enhancing charging resource utilization and improving user experience. The key innovations include (1) dynamic adjustment of priority parameters for optimized resource allocation; (2) a dynamic charging station reservation algorithm based on load status and user arrival rates to prioritize high-priority users; (3) a scheduling strategy for low-priority vehicles to minimize waiting times for non-reserved vehicles; and (4) integration of real-time data with the DDPDQN algorithm for dynamic resource allocation and user matching. Simulation results indicate that the ACP strategy outperforms the FIFS and RFWDA strategies under high-load conditions (High-priority vehicle arrival rate: 22 EV/h, random vehicle arrival rate: 13 EV/h, maximum parking duration: 1200 s). Specifically, the ACP strategy reduces charging wait times by 96 s and 28 s, respectively, and charging journey times by 452 s and 73 s. Additionally, charging station utilization increases by 19.5% and 11.3%. For reserved vehicles, the ACP strategy reduces waiting times and journey times by 27 s and 188 s, respectively, while increasing the number of fully charged vehicles by 104. For non-reserved vehicles, waiting and journey times decrease by 213 s and 218 s, respectively, with a 75 s increase in fully charged vehicles. Overall, the ACP strategy outperforms traditional methods across several key metrics, demonstrating its advantages in resource optimization and scheduling.