Titanium dioxide (TiO2) is produced at high volumes and applied in many consumer and food products. Recent toxicokinetic modelling indicated the potential of TiO2 to accumulate in human liver and spleen upon daily oral exposure, which is not routinely investigated in chronic animal studies. A health risk from nanosized TiO2 particle consumption could not be excluded then. Here we show the first quantification of both total titanium (Ti) and TiO2 particles in 15 post-mortem human livers and spleens. These low-level analyses were enabled by the use of fully validated (single particle) inductively coupled plasma high resolution mass spectrometry ((sp)ICP-HRMS) detection methods for total Ti and TiO2 particles. The presence of TiO2 in the particles in tissues was confirmed by Scanning Electron Microscopy with energy dispersive X-ray spectrometry. These results prove that TiO2 particles are present in human liver and spleen, with ≥24% of nanosize (< 100 nm). The levels are below the doses regarded as safe in animals, but half are above the dose that is deemed safe for liver damage in humans when taking into account several commonly applied uncertainty factors. With these new and unique human data, we remain with the conclusion that health risks due to oral exposure to TiO2 cannot be excluded.
Surface water used for drinking water production is frequently monitored in The Netherlands using whole organism biomonitors, with for example Daphnia magna or Dreissena mussels, which respond to changes in the water quality. However, not all human-relevant toxic compounds can be detected by these biomonitors. Therefore, a new on-line biosensor has been developed, containing immobilized genetically modified bacteria, which respond to genotoxicity in the water by emitting luminescence. The performance of this sensor was tested under laboratory conditions, as well as under field conditions at a monitoring station along the river Meuse in The Netherlands. The sensor was robust and easy to clean, with inert materials, temperature control and nutrient feed for the reporter organisms. The bacteria were immobilized in sol-gel on either an optical fiber or a glass slide and then continuously exposed to water. Since the glass slide was more sensitive and robust, only this setup was used in the field. The sensor responded to spikes of genotoxic compounds in the water with a minimal detectable concentration of 0.01 mg/L mitomycin C in the laboratory and 0.1 mg/L mitomycin C in the field. With further optimization, which should include a reduction in daily maintenance, the sensor has the potential to become a useful addition to the currently available biomonitors.
(2013). Comments on “UV and UV/H2O2 Treatment: The Silver Bullet for By-product and Genotoxicity Formation in Water Production”. Ozone: Science & Engineering: Vol. 35, No. 6, pp. 519-520.