Mojtaba Nedaei

Dr. Mojtaba Nedaei

Department of Management and Engineering, University of Padua, Vicenza, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2018 in Frontiers in Energy
Verified
Journal Article
Closed access
PDF file
MFMaurizio Faccio
Maurizio Faccio
MGMauro Gamberi
Mauro Gamberi
Marco BortoliniMarco Bortolini
Marco Bortolini
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei

1 May 2014 in Energy Conversion and Management
Verified
Journal Article
Closed access
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei
EAEhsanolah Assareh
Ehsanolah Assareh
MBMojtaba Biglari
Mojtaba Biglari

1 August 2016 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
PNPedram Nojedehi
Pedram Nojedehi
Mohammad HeidariMohammad Heidari
Mohammad Heidari
AAAbtin Ataei
Abtin Ataei
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei
EKElnaz Kurdestani
Elnaz Kurdestani

1 September 2015 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AAAbtin Ataei
Abtin Ataei
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei
RRReza Rashidi
Reza Rashidi
CYChangkyoo Yoo
Changkyoo Yoo
Although much attention has been paid to the utilization of hybrid renewable energy systems for either commercial buildings or residential ones, rare studies dealt with the application of off-grid hybrid renewable energy systems for commercial buildings. This paper presents a comprehensive study on the techno-economic performance of a stand-alone hybrid photovoltaic (PV)-wind-battery system for an office building located in Tehran, Iran. The Hybrid Optimization Model for Electric Renewables model was used to investigate the optimal design options and the techno-economic viability of the hybrid renewable energy system installed in that building. The proposed hybrid system based on renewable resources was designed to electrify the restrooms of the building. An optimal system configuration was chosen based on the total net present cost (NPC) and cost of energy (COE). The simulation results demonstrated that the optimum structure for the hybrid system for the primary load demand of 5.6 kW h per day, consists of 3 kW PV modules, 1 kW wind turbine, 1 kW inverter, and sixteen 200 A h batteries. The total NPC of such a system was estimated to be $21 132, while the COE was $1.543 per kW h. In addition, the proposed hybrid energy system could provide 2733 kW h additional electricity to the office building. Furthermore, in the last part of this research, a sensitivity analysis for different parameters such as primary load, wind speed, global solar radiation, interest rate, total NPC, cost of electricity, number of batteries and total electrical production was performed to demonstrate and elaborate the effect of each decision variable on the configuration of the optimum hybrid system. It became clear that two hybrid system configurations, i.e., PV-Wind-Battery and PV-Battery systems, are suggested as the most economical and feasible alternatives and have wide range of usage for different load demand values. Additionally based on the change in the initial design parameters such as wind speed, global solar radiation, load demand, and the real interest rate, a comparison between these two hybrid systems in terms of the total NPC, COE, electrical production, excess electricity, and grid extension distance has been made to investigate the effect of each decision variable on the optimal combination and the techno-economic viability of the hybrid renewable energy system.

29 April 2015 in Environmental Progress & Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AAAbtin Ataei
Abtin Ataei
MBMojtaba Biglari
Mojtaba Biglari
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei
EAEhsanolah Assareh
Ehsanolah Assareh
JCJun‐Ki Choi
Jun‐Ki Choi
MAMuyiwa S. Adaramola
Muyiwa S. Adaramola

12 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
EAEhsanolah Assareh
Ehsanolah Assareh
MJMasoud Jafarian
Masoud Jafarian
Mojtaba NedaeiMojtaba Nedaei
Mojtaba Nedaei
MFMohammad Firoozzadeh
Mohammad Firoozzadeh
Moonyong LeeMoonyong Lee
Moonyong Lee
Population and economic growth, industrial activities, development of technology, and depletion of fossil fuels have all led to increasing energy demand. As a result, there is an increasing ambition towards implementation of sustainable energy sources. In this study, first, a review of the literature is conducted to learn about various methods and objectives for optimization of photovoltaic and thermal (PV/T) systems. Then, a case study is considered, and the seasonal and hourly solar radiation are studied. Further, two methods of multiobjective evolutionary algorithm based on decomposition (MOEA/D) and multiobjective particle swarm optimization (MOPSO) are compared. On this basis, the energy and exergy efficiencies are analyzed for a proposed PV/T system. The outcomes are validated by taking into account the previous studies, and a sufficient agreement is found indicating the validity and accuracy of the results. It is also found that the efficiency rates for both energy and exergy soar with a rise in the ambient temperature. Additionally, a growth in the warm water flow rate from 0.4 to 1 kg/s increases the exergy efficiency by 0.6%. It is concluded that the MOEA/D method outperforms the MOPSO in terms of the optimization of the proposed PV/T system.