Jessica Gemignani

Dr. Jessica Gemignani

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2016 in Nature Communications
Verified
Journal Article
Open access
SFSimon P. Fisher
Simon P. Fisher
NCNanyi Cui
Nanyi Cui
LMLaura E. McKillop
Laura E. McKillop
JGJessica Gemignani
Jessica Gemignani
DBDavid M. Bannerman
David M. Bannerman
VVVladyslav V. Vyazovskiy
Vladyslav V. Vyazovskiy
Prolonged wakefulness is thought to gradually increase ‘sleep need’ and influence subsequent sleep duration and intensity, but the role of specific waking behaviours remains unclear. Here we report the effect of voluntary wheel running during wakefulness on neuronal activity in the motor and somatosensory cortex in mice. We find that stereotypic wheel running is associated with a substantial reduction in firing rates among a large subpopulation of cortical neurons, especially at high speeds. Wheel running also has longer-term effects on spiking activity across periods of wakefulness. Specifically, cortical firing rates are significantly higher towards the end of a spontaneous prolonged waking period. However, this increase is abolished when wakefulness is dominated by running wheel activity. These findings indicate that wake-related changes in firing rates are determined not only by wake duration, but also by specific waking behaviours.

23 November 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Federico CarpiFederico Carpi
Federico Carpi
GFGabriele Frediani
Gabriele Frediani
CGCarlo Gerboni
Carlo Gerboni
JGJessica Gemignani
Jessica Gemignani
DRDanilo De Rossi
Danilo De Rossi
Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch or resist voluntary movements of fingers or wrist. These simple systems are limited by the impossibility of modulating the mechanical stiffness. This limitation does not allow for customizations and real-time control of the training exercise, which would improve the rehabilitation efficacy. To overcome this limitation, 'active' orthoses equipped with devices that allow for electrical control of the mechanical stiffness are needed. Here, we report on a solution that relies on compact and light-weight electroactive elastic transducers that replace the passive elastic components. We developed a variable-stiffness transducer made of dielectric elastomers, as the most performing types of electromechanically active polymers. The transducer was manufactured with a silicone film and tested with a purposely-developed stiffness control strategy that allowed for electrical modulations of the force-elongation response. Results showed that the proposed new technology is a promising and viable solution to develop electrically controllable dynamic hand orthoses for hand rehabilitation.

1 April 2021 in Developmental Cognitive Neuroscience
Verified
Journal Article
Open access
JGJessica Gemignani
Jessica Gemignani
JGJudit Gervain
Judit Gervain
Functional Near Infrared Spectroscopy (fNIRS) is an important neuroimaging technique in cognitive developmental neuroscience. Nevertheless, there is no general consensus yet about best pre-processing practices. This issue is highly relevant, especially since the development and variability of the infant hemodynamic response (HRF) is not fully known. Systematic comparisons between analysis methods are thus necessary. We investigated the performance of five different pipelines, selected on the basis of a systematic search of the infant NIRS literature, in two experiments. In Experiment 1, we used synthetic data to compare the recovered HRFs with the true HRF and to assess the robustness of each method against increasing levels of noise. In Experiment 2, we analyzed experimental data from a published study, which assessed the neural correlates of artificial grammar processing in newborns. We found that with motion artifact correction (as opposed to rejection) a larger number of trials were retained, but HRF amplitude was often strongly reduced. By contrast, artifact rejection resulted in a high exclusion rate but preserved adequately the characteristics of the HRF. We also found that the performance of all pipelines declined as the noise increased, but significantly less so than if no pre-processing was applied. Finally, we found no difference between running the pre-processing on optical density or concentration change data. These results suggest that pre-processing should thus be optimized as a function of the specific quality issues a give dataset exhibits.

9 May 2018 in Journal of Neural Engineering
Verified
Journal Article
Open access
JGJessica Gemignani
Jessica Gemignani
EMEike Middell
Eike Middell
RBRandall L Barbour
Randall L Barbour
HGHarry L Graber
Harry L Graber
BBBenjamin Blankertz
Benjamin Blankertz
Objective . The statistical analysis of functional near infrared spectroscopy (fNIRS) data based on the general linear model (GLM) is often made difficult by serial correlations, high inter-subject variability of the hemodynamic response, and the presence of motion artifacts. In this work we propose to extract information on the pattern of hemodynamic activations without using any a priori model for the data, by classifying the channels as ‘ active ’ or ‘ not active ’ with a multivariate classifier based on linear discriminant analysis (LDA). Approach . This work is developed in two steps. First we compared the performance of the two analyses, using a synthetic approach in which simulated hemodynamic activations were combined with either simulated or real resting-state fNIRS data. This procedure allowed for exact quantification of the classification accuracies of GLM and LDA. In the case of real resting-state data, the correlations between classification accuracy and demographic characteristics were investigated by means of a Linear Mixed Model. In the second step, to further characterize the reliability of the newly proposed analysis method, we conducted an experiment in which participants had to perform a simple motor task and data were analyzed with the LDA-based classifier as well as with the standard GLM analysis. Main results . The results of the simulation study show that the LDA-based method achieves higher classification accuracies than the GLM analysis, and that the LDA results are more uniform across different subjects and, in contrast to the accuracies achieved by the GLM analysis, have no significant correlations with any of the demographic characteristics. Findings from the real-data experiment are consistent with the results of the real-plus-simulation study, in that the GLM-analysis results show greater inter-subject variability than do the corresponding LDA results. Significance . The results obtained suggest that the outcome of GLM analysis is highly vulnerable to violations of theoretical assumptions, and that therefore a data-driven approach such as that provided by the proposed LDA-based method is to be favored.

1 April 2025 in Neurophotonics
Verified
Journal Article
Open access
KSKatharina Stute
Katharina Stute
LGLouisa Gossé
Louisa Gossé
SMSamuel Montero-Hernandez
Samuel Montero-Hernandez
GPGuy A. Perkins
Guy A. Perkins
MYMeryem A. Yücel
Meryem A. Yücel
HZHanieh Zainodini
Hanieh Zainodini
SignificanceA shared understanding of terminology is essential for clear scientific communication and minimizing misconceptions. This is particularly challenging in rapidly expanding, interdisciplinary domains that utilize functional near-infrared spectroscopy (fNIRS), where researchers come from diverse backgrounds and apply their expertise in fields such as engineering, neuroscience, and psychology.AimThe fNIRS Glossary Project was established to develop a community-sourced glossary covering key fNIRS terms, including those related to the continuous-wave (CW), frequency-domain (FD), and time-domain (TD) NIRS techniques.ApproachThe glossary was collaboratively developed by a diverse group of 76 fNIRS researchers, representing a wide range of career stages (from PhD students to experts) and disciplines. This collaborative process, structured across five phases, ensured the glossary’s depth and comprehensiveness.ResultsThe glossary features over 300 terms categorized into six key domains: analysis, experimental design, hardware, neuroscience, mathematics, and physics. It also includes abbreviations, symbols, synonyms, references, alternative definitions, and figures where relevant.ConclusionsThe fNIRS glossary provides a community-sourced resource that facilitates education and effective scientific communication within the fNIRS community and related fields. By lowering barriers to learning and engaging with fNIRS, the glossary is poised to benefit a broad spectrum of researchers, including those with limited access to educational resources.

10 March 2023 in Neurophotonics
Verified
Journal Article
Open access
PDF file
JGJessica Gemignani
Jessica Gemignani
ICIrene de la Cruz-Pavía
Irene de la Cruz-Pavía
AMAnna Martinez
Anna Martinez
CNCaroline Nallet
Caroline Nallet
APAlessia Pasquini
Alessia Pasquini
JGJudit Gervain
Judit Gervain
Since the introduction of near-infrared spectroscopy, its use has grown dramatically in the neurosciences, particularly in developmental cognitive neuroscience,1,2 due to its many practical advantages: ease of use, portability, noninvasiveness, and low cost.