Stewart S Dalton

Stewart S Dalton

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in JSES International
Verified
Journal Article
Open access
SSSarav S. Shah
Sarav S. Shah
BGBenjamin T. Gaal
Benjamin T. Gaal
ARAlexander M. Roche
Alexander M. Roche
SNSurena Namdari
Surena Namdari
BGBrian M. Grawe
Brian M. Grawe
LGLawrence V. Gulotta
Lawrence V. Gulotta
Globally, reverse shoulder arthroplasty (RSA) has moved away from the Grammont design to modern prosthesis designs. The purpose of this 2-part study was to systematically review each of the most common complications of RSA, limiting each search to publications in 2010 or later. In this part (part I), we examined (1) scapular notching (SN), (2) periprosthetic infection (PJI), (3) mechanical failure (glenoid or humeral component), and (4) neurologic injury (NI). Four separate PubMed database searches were performed following Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Overall, 113 studies on SN, 62 on PJI, 34 on mechanical failure, and 48 on NI were included in our reviews. Univariate analysis was performed with the χ2 or Fisher exact test. The Grammont design had a higher SN rate vs. all other designs combined (42.5% vs. 12.3%, P < .001). The onlay humeral design had a lower rate than the lateralized glenoid design (10.5% vs. 14.8%, P < .001). The PJI rate was 2.4% for primary RSA and 2.6% for revision RSA. The incidence of glenoid and humeral component loosening was 2.3% and 1.4%, respectively. The Grammont design had an increased NI rate vs. all other designs combined (0.9% vs. 0.1%, P = .04). Focused systematic reviews of the recent literature with a large volume of RSAs demonstrate that with the use of non-Grammont modern prosthesis designs, complications including SN, PJI, glenoid component loosening, and NI are significantly reduced compared with previous studies. As the indications for RSA continue to expand, it is imperative to accurately track the rates and types of complications to justify its cost and increased indications.

1 November 2016 in Journal of Urology
Verified
Journal Article
Closed access
ECEugene B. Cone
Eugene B. Cone
SDStewart S Dalton
Stewart S Dalton
MNMegan Van Noord
Megan Van Noord
ETElizabeth T. Tracy
Elizabeth T. Tracy
HRHenry E. Rice
Henry E. Rice
JRJonathan C. Routh
Jonathan C. Routh
Wilms tumor is the most common childhood renal malignancy and the fourth most common childhood cancer. Many biomarkers have been studied but there has been no comprehensive summary. We systematically reviewed the literature on biomarkers in Wilms tumor to quantify the prognostic implications of the presence of individual tumor markers. We searched for English language studies from 1980 to 2015 performed in patients younger than 18 years with Wilms tumor and prognostic data. The protocol was conducted per PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Two reviewers abstracted data in duplicate using a standard evaluation form. We performed descriptive statistics, then calculated relative risks and 95% confidence intervals for markers appearing in multiple level II or III studies. A total of 40 studies were included examining 32 biomarkers in 7,381 patients with Wilms tumor. Studies had a median of 61 patients, 24 biomarker positive patients per series and a median followup of 68.4 months. Median percentages of patients with stages 1, 2, 3, 4 and 5 tumors were 28.5%, 26.4%, 24.5%, 14.1% and 1.7%, respectively, and 10.2% had anaplasia. The strongest negative prognostic association was loss of heterozygosity at 11p15, with a risk of recurrence of 5.00, although loss of heterozygosity at 1p and gain of function at 1q were also strongly linked to increased recurrence (2.93 and 2.86, respectively). Several tumor markers are associated with an increased risk of recurrence or a decreased risk of overall survival in patients with Wilms tumor. These data suggest targets for development of diagnostic tests and potential therapies.

1 January 2021 in JSES International
Verified
Journal Article
Open access
SSSarav S. Shah
Sarav S. Shah
ARAlexander M. Roche
Alexander M. Roche
SSSpencer W. Sullivan
Spencer W. Sullivan
BGBenjamin T. Gaal
Benjamin T. Gaal
SDStewart S Dalton
Stewart S Dalton
LGLawrence V. Gulotta
Lawrence V. Gulotta
Globally, reverse shoulder arthroplasty (RSA) has moved away from the Grammont design to modern prosthesis designs. The purpose of this study was to provide a focused, updated systematic review for each of the most common complications of RSA by limiting each search to publications after 2010. In this part II, the following were examined: (1) instability, (2) humerus/glenoid fracture, (3) acromial/scapular spine fractures (AF/SSF), and (4) problems/miscellaneous. Four separate PubMed database searches were performed following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Overall, 137 studies for instability, 94 for humerus/glenoid fracture, 120 for AF/SSF, and 74 for problems/miscellaneous were included in each review, respectively. Univariate analysis was performed with chi-square and Fisher exact tests. The Grammont design had a higher instability rate vs. all other designs combined (4.0%, 1.3%; P < .001), and the onlay humerus design had a lower rate than the lateralized glenoid design (0.9%, 2.0%; P = .02). The rate for intraoperative humerus fracture was 1.8%; intraoperative glenoid fracture, 0.3%; postoperative humerus fracture, 1.2%; and postoperative glenoid fracture, 0.1%. The rate of AF/SSF was 2.6% (371/14235). The rate for complex regional pain syndrome was 0.4%; deltoid injury, 0.1%; hematoma, 0.3%; and heterotopic ossification, 0.8%. Focused systematic reviews of recent literature with a large volume of shoulders demonstrate that using non-Grammont modern prosthesis designs, complications including instability, intraoperative humerus and glenoid fractures, and hematoma are significantly reduced compared with previous studies. As the indications continue to expand for RSA, it is imperative to accurately track the rate and types of complications in order to justify its cost and increased indications.

3 February 2023 in HAND
Verified
Journal Article
Closed access
SDStewart S Dalton
Stewart S Dalton
LMLaura M. Maharjan
Laura M. Maharjan
HYHayyan Yousuf
Hayyan Yousuf
WIWilliam F Pientka II
William F Pientka II
Background: The purpose of this study was to examine the clinical outcomes of extensor tendon repairs based on zone of injury. Methods: A retrospective chart review was conducted on all patients who underwent primary extensor tendon repair at our institution. Extensor tendon repairs were performed using a multiple figure-of-8 suture technique for extensor zones 1-4 and a modified Kessler suture technique for extensor zones 5-8. Inclusion criteria included a minimum of 8 weeks of follow-up, complete data available for review, and extensor tendon injury requiring primary surgical repair. Results: A total of 132 digits were included for analysis: 46 digits in zones 1-4 and 86 digits in zones 5-8. The operative time for zone 1-4 injuries averaged 88.96 minutes, and the operative time for zone 5-8 injuries averaged 114.42 minutes. Final extension was found to be 2.33° for zones 1-4 and 6.66° for zones 5-8. Final flexion was found to be 141.4° for zones 1-4 and 195.3° for zones 5-8. There was 1 infection identified in zones 1-4 and 7 in zones 5-8. Conclusions: Surgically repaired extensor tendons in zones 1-4 were found to have a statistically significant worse final flexion compared with surgically repaired extensor tendons in zones 5-8. No significant differences were found in final extension, complication rates, and time to full activity. Operative times for zone 5-8 tendon repairs were found to be significantly longer than operative times for zone 1-4 repairs, possibly due to more complex injury patterns seen in the more proximal zones.

5 May 2023 in The Journal of Hand Surgery (Asian-Pacific Volume)
Verified
Journal Article
Closed access
PDF file
SDStewart S Dalton
Stewart S Dalton
LMLaura M. Maharjan
Laura M. Maharjan
HYHayyan Yousuf
Hayyan Yousuf
WPWilliam F. Pientka
William F. Pientka

5 January 2024 in HAND
Verified
Journal Article
Closed access
VHVictoria S. Hoelscher
Victoria S. Hoelscher
MMMadison Milhoan
Madison Milhoan
MQMark Quiring
Mark Quiring
KFKassidy Fix
Kassidy Fix
SDStewart S Dalton
Stewart S Dalton
WIWilliam F Pientka II
William F Pientka II
Background: Metacarpal fractures are common orthopedic injuries with potentially debilitating outcomes. Ideal surgical treatment remains a topic of debate, with intramedullary fixation becoming popular as a technique to allow for earlier mobilization with few reported complications. The aim of this study was to report observed outcomes and complications of intramedullary metacarpal fixation using the ExsoMed INnate metacarpal nail. Methods: A retrospective chart review of 37 patients with 44 metacarpals treated with the ExsoMed INnate between July 2020 and December 2021 by a single fellowship-trained hand surgeon at a single level 1 trauma center was performed. Variables recorded included both patient and injury demographics, surgical complications, and postoperative outcomes. We also measured metacarpal isthmus diameter of the second to fifth metacarpals on all patients to determine the intramedullary canal diameter to assist in implant size selection. Results: Average follow-up was 5.84 weeks with average time to radiographic healing of 5.5 weeks, and time to full activity 6.32 weeks. The mean postsurgical active total arc of motion was 250°, while passive total arc of motion was 259.74°. A total of 10 complications (22%) were identified, including 4 bent screws which occurred as a result of a punching event postoperatively. Conclusions: Intramedullary fixation of metacarpal fractures using the ExsoMed INnate metacarpal nail has shown to preserve range of motion and quick return to full activity, with a low rate of major complications. Our study highlights the potential major complication of the bent intramedullary screw and its association with an initial punching mechanism.