Zeguan Wang

Dr. Zeguan Wang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2017 in eLife
Verified
Journal Article
Open access
LCLin Cong
Lin Cong
ZWZeguan Wang
Zeguan Wang
YCYuming Chai
Yuming Chai
WHWei Hang
Wei Hang
CSChunfeng Shang
Chunfeng Shang
QWQuan Wen
Quan Wen
The internal brain dynamics that link sensation and action are arguably better studied during natural animal behaviors. Here, we report on a novel volume imaging and 3D tracking technique that monitors whole brain neural activity in freely swimming larval zebrafish (Danio rerio). We demonstrated the capability of our system through functional imaging of neural activity during visually evoked and prey capture behaviors in larval zebrafish.

20 October 2020 in Optica
Verified
Journal Article
Closed access
YYYoung-Gyu Yoon
Young-Gyu Yoon
ZWZeguan Wang
Zeguan Wang
NPNikita Pak
Nikita Pak
DPDemian Park
Demian Park
PDPeilun Dai
Peilun Dai
EBEdward S. Boyden
Edward S. Boyden
One of the major challenges in large scale optical imaging of neuronal activity is to simultaneously achieve sufficient temporal and spatial resolution across a large volume. Here, we introduce sparse decomposition light-field microscopy (SDLFM), a computational imaging technique based on light-field microscopy (LFM) that takes algorithmic advantage of the high temporal resolution of LFM and the inherent temporal sparsity of spikes to improve effective spatial resolution and signal-to-noise ratios (SNRs). With increased effective spatial resolution and SNRs, neuronal activity at the single-cell level can be recovered over a large volume. We demonstrate the single-cell imaging capability of SDLFM with in vivo imaging of neuronal activity of whole brains of larval zebrafish with estimated lateral and axial resolutions of ∼ 3.5 µ m and ∼ 7.4 µ m , respectively, acquired at volumetric imaging rates up to 50 Hz. We also show that SDLFM increases the quality of neural imaging in adult fruit flies.

16 December 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
ZWZeguan Wang
Zeguan Wang
JZJie Zhang
Jie Zhang
PSPanagiotis Symvoulidis
Panagiotis Symvoulidis
WGWei Guo
Wei Guo
LZLige Zhang
Lige Zhang
EBEdward Boyden
Edward Boyden
Neurons interact in networks distributed throughout the brain. Although much effort has focused on whole-brain calcium imaging, recent advances in genetically encoded voltage indicators (GEVIs) raise the possibility of imaging voltage of neurons distributed across brains. To achieve this, a microscope must image at high volumetric rate and signal-to-noise ratio. We present a remote scanning light-sheet microscope capable of imaging GEVI-expressing neurons distributed throughout entire brains of larval zebrafish at a volumetric rate of 200.8 Hz. We measured voltage of ∼1/3 of the neurons of the brain, distributed throughout. We observed that neurons firing at different times during a sequence were located at different brain locations, for sequences elicited by a visual stimulus, which mapped onto locations throughout the optic tectum, as well as during stimulus-independent bursts, which mapped onto locations in the cerebellum and medulla. Whole-brain voltage imaging may open up frontiers in the fundamental operation of neural systems.

30 January 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
JVJosué Page Vizcaíno
Josué Page Vizcaíno
PSPanagiotis Symvoulidis
Panagiotis Symvoulidis
ZWZeguan Wang
Zeguan Wang
JJJonas Jelten
Jonas Jelten
PFPaolo Favaro
Paolo Favaro
TLTobias Lasser
Tobias Lasser
Real-time 3D fluorescence microscopy is crucial for the spatiotemporal analysis of live organisms, such as neural activity monitoring. The eXtended field-of-view light field microscope (XLFM), also known as Fourier light field microscope, is a straightforward, single snapshot solution to achieve this. The XLFM acquires spatial-angular information in a single camera exposure. In a subsequent step, a 3D volume can be algorithmically reconstructed, making it exceptionally well-suited for real-time 3D acquisition and potential analysis. Unfortunately, traditional reconstruction methods (like deconvolution) require lengthy processing times (0.0220 Hz), hampering the speed advantages of the XLFM. Neural network architectures can overcome the speed constraints but do not automatically provide a way to certify the realism of their reconstructions, which is essential in the biomedical realm. To address these shortcomings, this work proposes a novel architecture to perform fast 3D reconstructions of live immobilized zebrafish neural activity based on a conditional normalizing flow. It reconstructs volumes at 8 Hz spanning 512x512x96 voxels, and it can be trained in under two hours due to the small dataset requirements (50 image-volume pairs). Furthermore, normalizing flows provides a way to compute the exact likelihood of a sample. This allows us to certify whether the predicted output is in- or ood, and retrain the system when a novel sample is detected. We evaluate the proposed method on a cross-validation approach involving multiple in-distribution samples (genetically identical zebrafish) and various out-of-distribution ones.

4 January 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
BCBo Cai
Bo Cai
XZXiaomin Zhai
Xiaomin Zhai
ZWZeguan Wang
Zeguan Wang
YSYan Shen
Yan Shen
RXRonald Xu
Ronald Xu
KCKaiqin Chu
Kaiqin Chu
Monitoring and manipulating neuronal activities with optical microscopy desires a method where light can be focused or projected over a long axial range so that large brain tissues (>100 μm thick) can be simultaneously imaged, and specific brain regions can be optogenetically stimulated without the need for slow optical refocusing. However, the micron-scale resolution required in neuronal imaging yields a depth of field of less than 10 μm in conventional imaging systems. We propose to use a circularly symmetric phase mask to extend the depth of field. A numerical study shows that our method maintains both the peak and the shape of the point spread function vs the axial position better than current methods. Imaging of a 3D bead suspension and sparsely labelled thick brain tissue confirms the feasibility of the system for fast volumetric imaging.

22 August 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
YQYong Qian
Yong Qian
OCOrhan T. Celiker
Orhan T. Celiker
ZWZeguan Wang
Zeguan Wang
BGBurcu Guner-Ataman
Burcu Guner-Ataman
EBEdward Boyden
Edward Boyden
Molecular signals interact to mediate diverse biological computations. Ideally one would be able to image many signals at once, in the same living cell, to reveal how they work together. Here we report temporally multiplexed imaging (TMI), which uses the clocklike properties of fluorescent proteins to enable different cellular signals to be represented by different temporal fluorescence codes. Using different photoswitchable fluorescent proteins to represent different cellular signals, we can linearly decompose a brief movie of the fluorescence fluctuations in a given cell, into a sum of the fluctuation traces of each individual fluorophore, each weighted by its respective signal amplitude. We demonstrate the power of TMI to report relationships amongst a diversity of second messenger, kinase, and cell cycle signals, using ordinary microscopes. One-Sentence Summary Imaging of many dynamic signals in a living cell is possible by using distinct clocklike fluorophores to represent the activity of each signal.