Grzegorz Wroblewski

Dr. Grzegorz Wroblewski


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
DJDaniel Janczak
Daniel Janczak
MSMarcin Sloma
Marcin Sloma
GWGrzegorz Wroblewski
Grzegorz Wroblewski
MSMarcin Sloma
Marcin Sloma
Małgorzata JakubowskaMałgorzata Jakubowska
Małgorzata Jakubowska
Polymer composites with nanomaterials such as graphene nanoplatelets and carbon nanotubes are a new group of materials with high application possibilities in printed and flexible electronics. In this study such carbon nanomaterials were used as a conductive phase in polymer composites. Pastes with dispersed nanomaterials in PMMA and PVDF vehicles were screen printed on flexible substrates, and used as an active layer in pressure sensors, exploiting contact resistance phenomena. The relationship between resistance and pressure is nearly linear on a logarithmic scale for selected types of samples, and their response is several times higher than for similar sensors with graphite layers. The use of surfactants allowed us to fabricate evenly dispersed nanomaterials with different amount of nanoplatelets and nanotubes in the composites. The samples contained from 1.25 wt.% to 2 wt.% of graphene and 1 wt.% to 0.5 wt.% of nanotubes and exhibited diverse sheet resistivity. Experiments revealed the relationship between morphology and loading of functional phase in the polymer matrix and the sensors’ sensitivity.

28 January 2014 in Circuit World
Verified
Journal Article
Closed access
MSMarcin Sloma
Marcin Sloma
DJDaniel Janczak
Daniel Janczak
GWGrzegorz Wroblewski
Grzegorz Wroblewski
AMAnna Mlozniak
Anna Mlozniak
Małgorzata JakubowskaMałgorzata Jakubowska
Małgorzata Jakubowska
Purpose: – New types of substrates were used for fabrication of printed electroluminescent structures. Polymer foils mainly used as substrates for such optoelectronic elements were replaced with paper and textiles. Printing on non-transparent substrate requires elaboration of printed transparent electrode, while usually polyester foils with sputtered ITO transparent electrodes are used. The paper aims to discuss these issues. Design/methodology/approach: – Electroluminescent structures were fabricated with elaborated polymer compositions filled with nanomaterials, such as carbon nanotubes and graphene platelets, dielectric and luminophore nanopowders. Structures were printed as “reverse stack”, where transparent electrode is printed on top of the last luminophore layer. For that carbon nanotubes and graphene platelets filled composition was used, deposited with spray-coating technique. Findings: – Main issue with new substrates is proper wetting with the use of screen-printing pastes, and much higher roughness especially for textiles. Originality/value: – Fully functional structures were obtained, but several disadvantages were observed that needs to be eliminated in further studies.

6 March 2017 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
DJDaniel Janczak
Daniel Janczak
APAndrzej Peplowski
Andrzej Peplowski
GWGrzegorz Wroblewski
Grzegorz Wroblewski
LGLukasz Gorski
Lukasz Gorski
EZElzbieta Zwierkowska
Elzbieta Zwierkowska
Małgorzata JakubowskaMałgorzata Jakubowska
Małgorzata Jakubowska
The paper describes the investigations of pH-sensitive materials for screen printed flexible pH sensors. The sensors were fully printed and consisted of three layers, conductive made of low temperature-curable silver paste, insulating made of UV-curable dielectric paste, and pH-sensitive made of developed graphene/ruthenium oxide pastes. Graphene and ruthenium oxide composites were prepared with different proportions of graphene nanoplatelets paste and submicron ruthenium dioxide. To perform functional measurements, particular testing sensors were fabricated on flexible polyester foil. Afterwards electrochemical potential measurements of fabricated devices were carried out. Sensors were also exposed to cyclic bending and the change of pH sensitivity before and after bending was described. Eventually, percolation threshold concerning the amount of ruthenium oxide in the pH-sensitive layer was designated and UV influence on the sensitivity was observed that together allow for optimization of sensors’ fabrication costs.

15 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
DŁDamian Łukawski
Damian Łukawski
PHPatrycja Hochmańska-Kaniewska
Patrycja Hochmańska-Kaniewska
DJDominika Janiszewska-Latterini
Dominika Janiszewska-Latterini
GWGrzegorz Wroblewski
Grzegorz Wroblewski
Jeff PatmoreJeff Patmore
Jeff Patmore
ALAgnieszka Lekawa-Raus
Agnieszka Lekawa-Raus
Carbon nanotubes (CNTs) and graphene, with their unique mechanical, electrical, thermal, optical, and wettability properties, are very effective fillers for many types of composites. Recently, a number of studies have shown that CNTs and graphene may be integrated into wood–plastic composites (WPCs) and natural-fibre-reinforced polymer composites (NFPCs) to improve the existing performance of the WPCs/NFPCs as well as enabling their use in completely new areas of engineering. The following review analyses the results of the studies presented to date, from which it can be seen that that inclusion of CNTs/graphene may indeed improve the mechanical properties of the WPCs/NFPCs, while increasing their thermal conductivity, making them electroconductive, more photostable, less sensitive to water absorption, less flammable, and more thermally stable. This study indicates that the composition and methods of manufacturing of hybrid WPCs/NFPCs vary significantly between the samples, with a consequent impact on the level of improvement of specific properties. This review also shows that the incorporation of CNTs/graphene may enable new applications of WPCs/NFPCs, such as solar thermal energy storage devices, electromagnetic shielding, antistatic packaging, sensors, and heaters. Finally, this paper recognises key challenges in the study area, and proposes future work.

Verified
Journal Article
Open access
PDF file
LKLeszek Kołodziej
Leszek Kołodziej
OIOlga Iwasińska-Kowalska
Olga Iwasińska-Kowalska
GWGrzegorz Wroblewski
Grzegorz Wroblewski
TGTomasz Gizewski
Tomasz Gizewski
Małgorzata JakubowskaMałgorzata Jakubowska
Małgorzata Jakubowska
ALAgnieszka Lekawa-Raus
Agnieszka Lekawa-Raus
This paper presents methods for developing high-performance interface electrode materials designed to enhance signal collection efficacy during long-term (over 24 h) electrocardiography (ECG) monitoring. The electrode materials are fabricated by integrating commercial ECG liquid hydrogels with carbon nanotubes (CNTs), which are widely utilized in dry-electrode technologies and extensively discussed in the current scientific literature. The composite materials are either prepared by dispersing CNTs within the commercial liquid hydrogel matrix or by encasing the hydrogels in macroscopic CNT films. Both approaches ensure the optimal wetting of the epidermis via the hydrogels, while the CNTs reduce material impedance and stabilize the drying process. The resulting electrode materials maintain their softness, allowing for micro-conformal skin attachment, and are biocompatible. Empirical testing confirms that the ECG electrodes employing these hybrid hydrogels adhere to relevant standards for durations exceeding 24 h. These innovative hybrid solutions merge the benefits of both wet and dry ECG electrode technologies, potentially facilitating the extended monitoring of ECG signals and thus advancing the diagnosis and treatment of various cardiac conditions.

17 December 2015 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
KSKatarzyna Siuzdak
Katarzyna Siuzdak
MKMaciej Klein
Maciej Klein
MSMiroslaw Sawczak
Miroslaw Sawczak
GWGrzegorz Wroblewski
Grzegorz Wroblewski
MSMarcin Sloma
Marcin Sloma
ACAdam Cenian
Adam Cenian