New energy vehicles (NEVs) rely heavily on Insulated-Gate Bipolar Transistors (IGBTs) to perform frequent battery voltage conversions for operations such as acceleration, deceleration, and hill climbing. Consequently, effective thermal management of the IGBT junction temperature is critically important. This study investigates the junction temperature of IGBT modules equipped with pin-fin heat sinks of varying spacings under diverse operating conditions. The effects of the coolant inlet flow velocity and temperature on the junction temperature were examined. Furthermore, the pin-fin heat sink structure was optimized to enhance temperature uniformity across the IGBT chips. The results indicate that (1) IGBT modules with small-spacing pin-fin heat sinks exhibit improved thermal performance and enhanced temperature uniformity under specific conditions; (2) coolant inlet flow velocity is positively correlated with both module cooling efficiency and temperature uniformity; (3) coolant inlet temperature is inversely correlated with module junction temperature and chip junction temperature uniformity; and (4) among the three optimization schemes evaluated, the dual-channel, non-uniformly spaced pin-fin heat sink delivered the optimal performance, reducing the maximum junction temperature difference between IGBT chips to approximately 0.5 °C and that between diode chips to approximately 1.0 °C.
During the cement production process, certain materials with relatively high levels of natural radioactivity are commonly incorporated. Without control, this may lead to a residential environment with prolonged elevated radioactivity, posing a potential threat to human health. In this study, a systematic investigation of radioactivity levels was conducted on cement samples from the three major regions of Chongqing: the main urban area, northeastern Chongqing, and southeastern Chongqing. Key parameters, including the activity concentrations of the radionuclides 226Ra, 232Th, and 40K; external hazard index; internal hazard index; the radium equivalent activity; and the additional annual effective dose from external gamma radiation, were calculated. X-ray fluorescence (XRF) analysis was also performed to examine the chemical composition of typical samples. The research findings indicate that all 57 tested cement samples from 20 plants complied with the radiation safety requirements. Among the sampled products, the radioactivity levels followed the order: main urban area > northeastern region > southeastern region. Specifically, the mean radium equivalent activity of samples from the main urban area was approximately 13.85% and 31.43% higher than those from northeastern and southeastern Chongqing, respectively. Statistical tests indicated that this regional difference was mainly driven by 226Ra, while 232Th and 40K showed no significant regional differences. Through XRF analysis of cement products and mineral raw materials with varying radioactivity levels, combined with Pearson correlation analysis, the radium equivalent activity was found to be positively correlated with the contents of TiO2 and ZrO2. Further analysis of individual radionuclides suggested that this correlation was mainly driven by 232Th, with a secondary contribution from 226Ra, whereas 40K showed no significant correlation. These results provide supporting data for evaluating the natural radioactivity levels in cement products from Chongqing.
To investigate the influence characteristics of building materials on the indoor radiation environment in practical applications and to quantitatively evaluate the regulatory effects of architectural design parameters on the indoor γ dose rate, a three-dimensional calculation model for the absorbed dose rate in air in a standard room was established using the Monte Carlo method, and the indoor dose field distribution was analyzed. The results show that the absorbed dose rate in air in a standard enclosed room exhibits a gradient distribution characterized by lower values at the center and higher values at the edges, with dose peaks appearing in corners and edge regions due to the superposition of multiple near-field sources. Sensitivity studies on building geometric parameters indicate that, when the room height is fixed, the central dose rate changes non-monotonically with the room volume: as the room volume expands from 2.8 m3 to approximately 25.2 m3, the central dose rate decreases, whereas it gradually increases compared to the standard room when further expanded to 280 m3. With a fixed floor area, the central dose rate shows a monotonically decreasing trend with increasing room height. After introducing realistic asymmetric openings such as doors and windows, the dose field presents significant asymmetric distribution characteristics. The influences of window size and position on the dose were analyzed, and a typical residential layout with an off-center door and a centered window was established. It is found that low-dose channels are formed in the extension areas of the openings, causing the indoor extreme dose points to deviate from the geometric center.