(1) Background: Hepatitis C virus (HCV) screening mostly uses a one-assay anti-HCV testing approach, which has a higher probability of false-positive results in populations with low HCV prevalence. (2) Methods: In this investigation, 17,926 participants were screened for HCV, and the reactives were tested using a two-assay anti-HCV approach: Elecsys ElectroChemiLuminescence (ECL) and a ChemiLuminescence ImmunoAssay (CLIA), respectively. A recombinant immunoblot assay (RIBA) was performed to confirm anti-HCV positivity. Statistical analysis was performed. (3) Results: A total of 350 specimens were reactive in the ECL screening, of which CLIA retesting showed that 292 (83.4%) were anti-HCV reactive (283 positives, 9 indeterminate, none negative by RIBA), but 58 (16.6%) were not anti-HCV reactive (15 positive, 12 indeterminate, 31 negatives by RIBA). The two-assay strategy significantly improved the positive predictive value (PPV: 95.00%) with χ2: 7.59 (p < 0.01) compared to the PPV assessed by one assay (PPV: 90.6%) with χ2: 34.51 (p < 0.001). The ROC curve defined a sensibility and specificity for the dual approach of 99.66% and 100.00%. (4) Conclusions: Compared with a one-assay testing strategy, the two-assay testing strategy may significantly reduce false positives in anti-HCV testing and identify inactive HCV infection in low seroprevalence populations.
The aim of this study was to investigate whether the presence of Staphylococcus aureus (SA) producing the Panton–Valentine leukocidin (PVL) affects the outcome of Prosthetic Joint Infection (PJI). Patients with acute and chronic PJI sustained by SA were prospectively enrolled at the orthopedic unit of “Casa di Cura Santa Maria Maddalena”, from January 2019 to October 2021. PJI diagnosis was reached according to the diagnostic criteria of the International Consensus Meeting on PJI of Philadelphia. Synovial fluid obtained via joint aspirations was collected in order to isolate SA. The detection of PVL was performed via real-time quantitative PCR (RT-qPCR). The outcome assessment was performed using the criteria of the Delphi-based International Multidisciplinary Consensus. Twelve cases of PJI caused by SA were included. Nine (75%) cases were acute PJI treated using debridement, antibiotic and implant retention (DAIR); the remaining three (25%) were chronic PJI treated using two-stage (n = 2) and one-stage revision (n = 1), respectively. The SA strains that tested positive for PVL genes were 5/12 (41.6%,). Treatment failure was documented in three cases of acute PJI treated using DAIR, all supported by SA–PVL strains (p < 0.045). The remaining two cases were chronic PJI treated with a revision arthroplasty (one and two stage, respectively), with a 100% eradication rate in a medium follow-up of 24 months. Although a small case series, our study showed a 100% failure rate in acute PJI, probably caused by SA PVL-producing strains treated conservatively (p < 0.04). In this setting, toxin research should guide radical surgical treatment and targeted antibiotic therapy.
(1) Background: Hepatitis C virus (HCV) screening mostly uses a one-assay anti-HCV testing approach, which has a higher probability of false-positive results in populations with low HCV prevalence. (2) Methods: In this investigation, 17,926 participants, were screened for HCV, and the reactives were tested using a two-assay anti-HCV approach: Elecsys ElectroChemiLuminescence (ECL) and a ChemiLuminescence ImmunoAssay (CLIA), respectively. A recombinant immunoblot assay (RIBA) was performed to confirm anti-HCV positivity. Statistical analysis was performed. (3) Results: A total of 350 specimens resulted reactive in the ECL screening, of which CLIA retesting showed that 292 (83.4%) were anti-HCV reactive (283 positive, 9 indeterminate, none negative by RIBA), but 58 (16.6%) were not anti-HCV reactive (15 positive, 12 indeterminate, 31 negative by RIBA). The two-assay strategy significantly improved the positive predictive value (PPV: 95.00%) with χ2: 7.59(p<0.01) then the PPV assessed by one assay (PPV: 90.6%) with χ2: 34.51 (p< 0.001). The ROC curve defined a sensibility and specificity for the dual approach of: 99.66% and 100.00%. (4) Conclusions: Compared with a one-assay testing strategy, the two-assay testing strategy may significantly reduce false positives in anti-HCV testing and identify inactive HCV infection in low seroprevalence populations.