In this article, a novel sensorless control scheme for doubly fed induction generator (DFIG) wind turbine systems based on the second-order generalized integrator (SOGI) and rotor position correction (RPC) is proposed. The rotor speed can be estimated from the SOGI structure with the inputs of the measured rotor currents and the grid frequency. Since the SOGI has the characteristic of the adaptive filter, the accurate estimation of rotor speed can be achieved despite the harmonics in the measured quantities. The RPC uses the SOGI outputs and the rotor currents, which are found based on the measured stator currents and voltages, to eliminate the estimated rotor position error. The effects of parameter variation on the estimation are investigated as well. The simulation and experimental results have verified the validity of the proposed method under the wind speed fluctuations and adverse grid conditions.
6 January 2022 in IEEE Transactions on Power Electronics
In this article, an improved grid synchronization method for three-phase grid-feeding converters using a dual enhanced second-order generalized integrator (eSOGI) frequency-locked loop (FLL) is proposed. The eSOGI, of which gains can be adjusted based on the positive-sequence component of the grid voltage, is designed to estimate the grid voltage accurately. Moreover, to improve the grid frequency estimation under grid voltage sags, frequency rate limits is suggested in the FLL structure. The selection of the eSOGI-FLL parameters is described as well. After the estimated grid voltages are obtained using the dual eSOGI-FLL, they are used to synthesize the references in the dual-current controllers for positive- and negative-sequence components. Through the simulation and experimental results under grid voltage sags and distorted grid conditions, the improved power control performance of the proposed method has been demonstrated in comparison with those of the existing methods.
In this paper, a novel sensorless control method for variable-speed squirrel-cage induction generator (SCIG) wind power systems with simple rotor flux estimation is proposed. The rotor flux linkages are estimated using a reduced-order generalized integrator (ROGI)-frequency-locked loop (FLL) which regards the rotor back-EMFs found from the generator model as its inputs. Based on these rotor flux linkages, the rotor flux angle can be estimated through direct trigonometric relations. Then, to avoid the speed estimation error caused by the FLL under stator frequency variations, the synchronous speed is estimated from the aforementioned rotor flux angle via the derivative. Owing to the excellent harmonic rejection capability of the ROGI, the proposed rotor flux estimation is robust against measured high-frequency ripple components. The analysis of ROGI response in the presence of DC offset in the rotor back-EMFs is provided as well, and it shows that the proposed method is not faced with the saturation under those conditions. Performance comparisons between the proposed method and the existing dual second-order generalized integrator (SOGI)-FLL-based method have been conducted via both simulations and experiments, thereby verifying the feasibility of the proposed method.
This paper proposes a novel algorithm for the parameter identification of induction motors based on third-order generalized integrators (TOGIs), where both the electrical and mechanical parameters are estimated. First, AC voltages of 0.7 V at 200 Hz and 1.2 V at 5 Hz superimposed on a DC bias component are injected into the induction motor by a PWM inverter, from which the amplitude of the stator current and the phase angle between stator voltage and stator current are calculated by the TOGI. These signals are used to estimate the stator transient inductance, rotor resistance, and rotor time constant precisely. On the other hand, a dynamic test is performed to identify the mechanical parameter. A sinusoidal speed reference is commanded to the induction motor, and the corresponding motor torque signal is then utilized to estimate the moment of inertia with the help of the TOGI. Since the TOGI behaves as an adaptive filter, the adverse effects of DC-offset and measurement noises are mitigated. The effectiveness of the proposed identification method has been verified by experimental results, showing errors of +2.6 % for the stator transient inductance, +2.8 % for the rotor resistance, and -1.8 % for the rotor time constant compared to those obtained following IEEE Std. 112; and 1.3 % for the moment of inertia compared to the value in the technical datasheet.
Vehicle-to-home (V2H) technology enables electric vehicles (EVs) to supply power to residential loads, offering enhanced energy self-sufficiency and backup capabilities. Accurate voltage regulation is essential in such systems, especially under nonlinear and time-varying load conditions. The control method for three-phase four-wire (3P4W) converters plays a vital role in addressing these challenges. In the control configuration of such systems, the non-ideal proportional-resonant (PR) controller stands out due to its ability to reject periodic disturbances. However, the comprehensive study on the discretization of this controller for digital implementation in 3P4W systems has not been available in the literature to date. This paper presents a comparative study of several discretization methods for non-ideal PR controllers. The continuous-time complete transfer function of the integral term of non-ideal PR controllers is discretized using techniques such as Forward Euler, Backward Euler, Tustin, Zero-Order Hold, and Impulse Invariance. Additionally, the discretization methods based on two discrete integrators for the non-ideal PR controller, such as Forward Euler and Backward Euler, Backward Euler and Backward Euler plus computational delay, and Tustin and Tustin, are also evaluated. In the MATLAB/Simulink platform, through evaluating the performance of the non-ideal PR controllers, which are discretized using the above discretization methods, in controlling the output voltage of the 3P4W converter in the V2H application under nonlinear load scenarios, including substantial and sudden changes in load, the discretization method Backward Euler and Backward Euler plus delay is recommended.