A wide-speed, ultra-light power generation system is a critical power generation unit structure, often because of its high efficiency and power density. Lightness and reliability are two key design indicators within the system, albeit they could lead to contradictory problems, particularly in systems containing prime movers, batteries, generators, rectifiers, and inverters. Ultra-light generator sets are facing more severe problems and contradictions in designing in terms of matching, coordinating, and stabilizing the components in the systems. This paper describes the system design of a low-cost and high-reliability microgenerator set: a gasoline engine, three-phase permanent magnet synchronous generator, rectifier, and inverter. Moreover, the matching relationship between the four parts and the design effect of each part of the power generation system was analyzed, simulated, and tested to verify the effectiveness and feasibility of the so-designed system.
The conventional power distributions methods face many challenges, such as high switching frequency, multiple carrier cycles, and single power distribution. To address the above issues, a novel power distribution based on the selective harmonic elimination (PD–SHE) strategy is proposed to achieve arbitrary power distribution and selective harmonic elimination but with low switching frequency and single carrier cycle. Firstly, the novel PD–SHE model is established based on the principles of SHE and power calculation theory, where distribution ratio is introduced to adjust power distribution arbitrarily and its constraints have been deduced. In addition, the issue of redundancy of solution is also analyzed and solved by adding valid constraints. Finally, polynomial homotopy continuation (PHC) algorithm is applied to solve the novel PD–SHE model. Then, all the physically realizable solutions can be found without choosing the initial value in the full range of modulation index. The results of simulation analysis show the effectiveness of PD–SHE strategy and the superiority of PHC algorithm in solving the global optimal solution. Moreover, the reliability of the global optimal solution for PD–SHE strategy is verified via physical experiments in terms of harmonic elimination and active power distribution.
In order to improve the output torque/current utilization of five-phase interior permanent magnet synchronous motor (FP-IPMSM) when running below base speed, a multi-dimensional maximum torque per ampere (MTPA) control strategy based on virtual signal injection (VSI) is proposed. Firstly, the mathematical model of FP-IPMSM containing third harmonic is derived, and the double-plane vector control is constructed. Secondly, the MTPA current is calculated according to the output torque, and the MTPA current trajectory of fundamental and harmonic planes is given. Thirdly, the dual-plane MTPA control strategy based on VSI is discussed. Finally, the effectiveness of the proposed control strategy is verified by simulation.
Ultralight power generation equipment has high requirements for the power density, continuous operation, and transient stability of the whole machine, and there is a direct conflict between high power density and substantial stability control in the power unit design. In order to meet the power density requirements of ultralight power stations, three main problems need to be solved, namely engine speed oscillation and flameout in the process of load power mutation, matching of the generator and engine torque, and stabilizing the voltage waveform of the AC output end. In this paper, we proposed an exquisite compound control strategy for ultralight power generation systems in engines, generators, and inverters. The effectiveness and practicability of the proposed strategy are verified by both simulation and experiment. The results show that the proposed control strategy can effectively solve the instability problem of the ultralight generator set and improve the stability of the system, where response recovery can be achieved within 0.9 s under the conditions of a total load increase or decrease, and the mismatching degree of the generator following the engine is reduced by 90%. The strategy could also guarantee long-term stable operation with high-quality electrical energy output.