Meinhard Reinert Hansen

Dr. Meinhard Reinert Hansen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MLMorten Lorentzen
Morten Lorentzen
AHAnne Heltborg
Anne Heltborg
FKFrida Kaldan
Frida Kaldan
MCMariana Bichuette Cartuliares
Mariana Bichuette Cartuliares
MHMathias Amdi Hertz
Mathias Amdi Hertz
CLChristian B. Laursen
Christian B. Laursen
The diagnostic accuracy of handheld ultrasound (HHUS) devices operated by newly certified operators for pneumonia is unknown. This multicenter diagnostic accuracy study included patients prospectively suspected of pneumonia from February 2021 to February 2022 in four emergency departments. The index test was a 14-zone focused lung ultrasound (FLUS) examination, with consolidation with air bronchograms as diagnostic criteria for pneumonia. FLUS examinations were performed by newly certified operators using HHUS. The reference standard was computed tomography (CT) and expert diagnosis using all medical records. The sensitivity and specificity of FLUS and chest X-ray (CXR) were compared using McNemar’s test. Of the 324 scanned patients, 212 (65%) had pneumonia, according to the expert diagnosis. FLUS had a sensitivity of 31% (95% CI 26–36) and a specificity of 82% (95% CI 78–86) compared with the experts’ diagnosis. Compared with CT, FLUS had a sensitivity of 32% (95% CI 27–37) and specificity of 81% (95% CI 77–85). CXR had a sensitivity of 66% (95% CI 61–72) and a specificity of 76% (95% CI 71–81) compared with the experts’ diagnosis. Compared with CT, CXR had a sensitivity of 69% (95% CI 63–74) and a specificity of 68% (95% CI 62–72). Compared with the experts’ diagnosis and CT diagnosis, FLUS performed by newly certified operators using HHUS devices had a significantly lower sensitivity for pneumonia when compared to CXR (p < 0.001). FLUS had a significantly higher specificity than CXR using CT diagnosis as a reference standard (p = 0.02). HHUS exhibited low sensitivity for pneumonia when used by newly certified operators.

8 March 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
LLLisbeth Lyhne
Lisbeth Lyhne
KHKim Christian Houlind
Kim Christian Houlind
JCJohnny Christensen
Johnny Christensen
RVRadu Vijdea
Radu Vijdea
MHMeinhard Reinert Hansen
Meinhard Reinert Hansen
HPHelle Precht
Helle Precht
This study aimed to test the accuracy of a magnetic resonance imaging (MRI)-based method to detect and characterise deep venous thrombosis (DVT) in the ilio-femoro-caval veins. Patients with verified DVT in the lower extremities with extension of the thrombi to the iliac veins, who were suitable for catheter-based venous thrombolysis, were included in this study. Before the intervention, magnetic resonance venography (MRV) was performed, and the ilio-femoro-caval veins were independently evaluated for normal appearance, stenosis, and occlusion by two single-blinded observers. The same procedure was used to evaluate digital subtraction phlebography (DSP), considered to be the gold standard, which made it possible to compare the results. A total of 123 patients were included for MRV and DSP, resulting in 246 image sets to be analysed. In total, 496 segments were analysed for occlusion, stenosis, or normal appearance. The highest sensitivity compared occlusion with either normal or stenosis (0.98) in MRV, while the lowest was found between stenosis and normal (0.84). Specificity varied from 0.59 (stenosis >< occlusion) to 0.94 (occlusion >< normal). The Kappa statistic was calculated as a measure of inter-observer agreement. The kappa value for MRV was 0.91 and for DSP, 0.80. In conclusion, MRV represents a sensitive method to analyse DVT in the pelvis veins with advantages such as no radiation and contrast and the possibility to investigate the anatomical relationship in the area.