Xin Liu

Dr. Xin Liu


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

17 May 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
XLXin Liu
Xin Liu
JYJiawei Yang
Jiawei Yang
GLGuishu Liang
Guishu Liang
LWLitong Wang
Litong Wang
A modified field‐to‐line coupling model for simulating the corona effect on the lightning induced voltages of the overhead multi‐conductor transmission lines is proposed in this study. Since the model is non‐linear, it is solved in an iterative way combining with the time‐domain finite‐element method and is validated by the measurements of Inoue's experiments. Furthermore, the unconditional stability of the numerical method is theoretically proved. The proposed model is a simplified method according to the method recently proposed by Thang et al. , in which finite difference time domain (FDTD) is used to calculate the induced voltages. Compared with FDTD, the proposed model can achieve good efficiency because the transmission line theory is adopted instead of the electromagnetic solution. Both the effects of the corona and the lossy ground on the induced voltage are studied, furthermore, the relationship between the corona effect and the soil conductivity is discussed. The simulation results demonstrate that the corona effect will cause a rise time increase and waveform distortion of the induced voltage, and the magnitudes of induced voltages in the presence of corona discharge are larger than those computed without considering corona.

1 January 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
XLXin Liu
Xin Liu
MZMengmeng Zhang
Mengmeng Zhang
TWTao Wang
Tao Wang
YGYumin Ge
Yumin Ge
In this study, an efficient method for the evaluation of lightning‐induced voltages on a single‐conductor overhead line and a single‐core buried cable is proposed. In this method, the numerical evaluation of the temporal convolution due to the lossy ground is simplified by a full consideration of the inherent relation between the frequency‐dependent ground impedance per‐unit‐length (p.u.l.) and admittance p.u.l., based on which, the evaluation of the lightning‐induced voltages on an overhead line or buried cable system can be implemented in an efficient way. To further improve the efficiency, the frequency‐domain method of evaluation of the lightning horizontal electric fields above or below the ground surface is modified by dividing the lightning channel base current into high‐frequency and low‐frequency components. Some numerical examples are conducted under MATLAB platform to validate the proposed method and the efficiency is discussed.

1 October 2016 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
XLXin Liu
Xin Liu
CTChenyang Ti
Chenyang Ti
GLGuishu Liang
Guishu Liang
The transient analysis of multi‐conductor transmission lines should consider the frequency‐dependent characteristics due to the skin effect. Fully considering the inherent fractional order characteristics of the frequency‐dependent effect, a general wide‐band modelling method is proposed. The fractional order vector fitting method is adopted to approximate the frequency‐dependent parameters and the corresponding fractional differential equations can be obtained by the inverse Laplace transformation. The backward difference is a practical method to solve the fractional differential equations; however, a linear convolution must be calculated, which will lead to a heavy computation complexity. To address this issue, a new recursive convolution method for the fractional differential equations is proposed and an efficient solution is achieved. Furthermore, considering the indispensability of the passivity verification of a system for the transient simulation, the passivity verification by extending the Hamiltonian matrix for the fractional order systems is studied and a practical criterion is proposed. Three examples are considered to validate the proposed method: (i) a single underground cable, (ii) three‐phase underground cable, and (iii) an experimental transformer under very fast transient voltage. The simulation results are compared with the results obtained by power systems computer‐aided design or measurements and good agreements are achieved.

27 May 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XLXin Liu
Xin Liu
LWLitong Wang
Litong Wang
GLGuishu Liang
Guishu Liang
LQLei Qi
Lei Qi
The calculation for carrier distribution in the quasi-neutral base region is necessary for modeling the turn- off process of an insulated gate bipolar transistor (IGBT). The carrier distribution difference between quasi static (QS) and nonquasi static (NQS) conditions and its influences on turn- off characteristics of a high-power IGBT are worthy of further study. In this article, the carrier distribution differences between QS and NQS conditions in different turn- off stages are first analyzed. In addition, based on the derived conclusions, a novel method modeling the turn- off process of high-power IGBTs is further proposed. In the method, the turn- off process before the collector–emitter voltage increases to the direct current (dc) voltage is modeled under the QS condition. In contrast, after the collector–emitter voltage increases to the dc voltage, the turn- off process is modeled under the NQS condition. Subsequently, the method is verified by comparisons with popular models and experiments. By adopting both QS and NQS assumptions, the proposed method can simplify the calculation and avoid considering the two-dimensional carrier distribution effect in the base. The method is implemented into SABER circuit simulator with MAST language and shows a high accuracy and considerable calculation efficiency.

23 August 2018 in IEEE Access
Verified
Journal Article
Open access
XLXin Liu
Xin Liu
ZFZiwei Fan
Ziwei Fan
GLGuishu Liang
Guishu Liang
TWTao Wang
Tao Wang
This paper presents a macro-model, which can be used to calculate the lightning-induced overvoltages (LIOVs) on overhead lines on MATLAB/Simulink platform. First, a macro-model according to Agrawal's field-to-line coupling model is derived, in which the distributed equivalent voltage sources due to the horizontal components of the incident electric fields are lumped at the terminals of the transmission lines. In order to interface with MATLAB/Simulink, the propagation function of the transmission line is approximated by a delayed rational function and described by a state-space representation, and Brune's synthesis is adopted to model the equivalent multiport equivalent circuit of the transmission line in order to overcome the passivity violation problem. Combining with the built-in components in MATLAB/Simulink, the proposed modeling approach is applied to evaluate LIOVs of an overhead lines system, and the influence of the arrester and ground wire on the LIOVs is discussed in this paper. Furthermore, considering that the peak values of LIOVs are mainly concerned in the insulation coordination, a simple model for the early time response is proposed, which can further simplify the procedure. The accuracy of the proposed modeling method is validated by some examples.