A green and cost-effective sonochemical synthetic method was followed for coating silver-modified copper oxide (Ag-CuO) nanoparticles (NPs) on disposable surgical mask. The NP-coated masks were systematically characterized using XRD and FT-IR for understanding the structural and surface functionalities. In addition, the field emission scanning electron microscopy (FE-SEM) analysis showed the homogeneous coating of Ag-CuO NPs over the mask fibers. The average particle size of Ag-CuO was found to be ~70 nm. The NP-coated masks are useful to combat a broad range of bacterial species by taking the unique advantage of the synergistic effect of Ag and metal oxide (CuO and ZnO) NPs for the generation of reactive oxygen species (ROS). Zone of inhibition (ZoI) studies demonstrated antibacterial activity against both Gram-positive S. aureus and Gram-negative E. coli bacteria, probably due to the elevated production of ROS by the defect structure of the Ag-modified metal oxide NPs. The material was found to be effective against both airborne and soil-borne bacteria. We repeat that this paper deals only with the killing effect of the nanoparticles (Ag-modified CuO) on bacteria, and no studies on viral species are performed.
During the synthesis of montelukast sodium drug substance from the intermediate 3-(2-(7-chloroquinolin-2-yl)-(E)-vinyl)benzaldehyde (alkene aldehyde), the purity of this intermediate is a critical factor that directly influences the overall quality and yield of the final drug product. To ensure consistent drug synthesis, strict process controls, analytical monitoring, and purification techniques must be implemented at each stage of intermediate production. With this motivation herein, a robust analytical method was developed and validated for the quantification of 7-Chloroquinaldine (7-CQ) in alkene aldehyde (AAI) in accordance with the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. By improving AAI purity, manufacturers can enhance drug quality, regulatory compliance, and overall production efficiency. HPLC analysis of AAI and related impurities to 7-CQ was performed using a Shimadzu LC 2010 binary system equipped with a UV detector at 230 nm and operated via LC solution software. Separation was achieved on an XBridge C18 column (150 × 4.6 mm, 5 μm) using a gradient mobile phase of 0.075% formic acid buffer and acetonitrile. Mobile phase A was prepared in a 1:1 ratio, while mobile phase B was prepared in a 1:9 ratio. Injection volume was 10 µL, and total run time was 35 min. The validated HPLC method for 7-CQ demonstrated linearity over the concentration range of 0.49–3.72 ppm with a correlation coefficient (r) of 0.9992 and a regression coefficient (R2) of 0.9983. The intercept and slope were 2415.09 ± 3348.29 and 61,762, respectively. The method exhibited high sensitivity with a limit of detection (LOD) of 0.0493 ppm and a limit of quantification (LOQ) of 0.4932 ppm. Precision was excellent, with a repeatability relative standard deviation %RSD of 0.04%, an intermediate precision % RSD of 4.57% and precision at LOQ of 5.76%. Accuracy was confirmed with recovery values ranging from 96.80% to 100% and % RSD values between 0.26% and 0.58%,demonstrating the method’s robustness, reproducibility, and suitability for routine quantitative analysis. These results confirm the reliability of the method for the routine analysis and detection of 7-CQ as an impurity in alkene aldehyde.