Charline Boente

Dr. Charline Boente

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2024 in Vision
Verified
Journal Article
Open access
PDF file
JCJordan Ross Crabtree
Jordan Ross Crabtree
STShadia Tannir
Shadia Tannir
KTKhoa Tran
Khoa Tran
CBCharline Boente
Charline Boente
AAAsim Ali
Asim Ali
GBGregory H Borschel
Gregory H Borschel
The measurement of corneal sensation allows clinicians to assess the status of corneal innervation and serves as a crucial indicator of corneal disease and eye health. Many devices are available to assess corneal sensation, including the Cochet–Bonnet aesthesiometer, the Belmonte Aesthesiometer, the Swiss Liquid Jet Aesthesiometer, and the newly introduced Corneal Esthesiometer Brill. Increasing the clinical use of in vivo confocal microscopy and optical coherence tomography will allow for greater insight into the diagnosis, classification, and monitoring of ocular surface diseases such as neurotrophic keratopathy; however, formal esthesiometric measurement remains necessary to assess the functional status of corneal nerves. These aesthesiometers vary widely in their mode of corneal stimulus generation and their relative accessibility, precision, and ease of clinical use. The development of future devices to optimize these characteristics, as well as further comparative studies between device types should enable more accurate and precise diagnosis and treatment of corneal innervation deficits. The purpose of this narrative review is to describe the advancements in the use of aesthesiometers since their introduction to clinical practice, compare currently available devices for assessing corneal innervation and their relative limitations, and discuss how the assessment of corneal innervation is crucial to understanding and treating pathologies of the ocular surface.

6 March 2024 in Journal of American Association for Pediatric Ophthalmology and Strabismus
Verified
Journal Article
Closed access
JCJay Chopra
Jay Chopra
KHKathryn M. Haider
Kathryn M. Haider
CBCharline Boente
Charline Boente

2 April 2025 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
STShadia Tannir
Shadia Tannir
CMChilando Mulenga
Chilando Mulenga
KTKhoa Tran
Khoa Tran
AAAsim Ali
Asim Ali
CBCharline Boente
Charline Boente
GBGregory H Borschel
Gregory H Borschel

1 July 2018 in Journal of Pediatric Ophthalmology & Strabismus
Verified
Journal Article
Closed access
PDF file
CBCharline Boente
Charline Boente
GJGriffin J. Jardine
Griffin J. Jardine
TDTina G. Damarjian
Tina G. Damarjian
DSDerek T. Sprunger
Derek T. Sprunger
GRGavin J. Roberts
Gavin J. Roberts
DPDavid A. Plager
David A. Plager
Purpose: To evaluate the use of immediate postoperative alignment measurements as a predictor of future alignment stability in fixed suture strabismus surgery. Methods: Forty-seven patients were prospectively evaluated after undergoing horizontal or vertical rectus muscle surgery using a fixed suture technique. Alignment measurements were taken approximately 1 hour, 1 to 3 weeks, and 2 to 3 months postoperatively. A Spearman correlation coefficient was used to compare measurements from the immediate postoperative period to the 2- to 3-month postoperative period. Patients with dissociated strabismus, only oblique muscle surgery, or poor vision in one or both eyes precluding precise alternate cover test were excluded. Results: Mean age of all patients was 46.7 years (range: 12 to 86 years). Twenty-two patients underwent surgery for exotropia: 19 for esotropia and 6 for hypertropia. Mean alignment for all surgeries was 2 prism diopters (PD) undercorrection in the immediate postoperative period, which was similar to the mean of 4.6 PD undercorrection at 2 to 3 months postoperatively. However, the Spearman correlation between the immediate postoperative and 2- to 3-month postoperative measurements was 0.18 for all surgeries, 0.03 for exotropia, 0.56 for esotropia, and 0.40 for hypertropia. The overall success rate, defined as 8 PD or less of horizontal deviation and 4 PD or less of vertical deviation, was 77% at 2 to 3 months postoperatively. Conclusions: The relationship between immediate postoperative alignment and future alignment stability in fixed suture strabismus surgery has not been previously defined. The current study demonstrated that although the surgical success rate was reasonably good, poor correlation occurred between the alignment immediately postoperatively and 2 to 3 months postoperatively. [J Pediatr Ophthalmol Strabismus. 200X;XX(X):XX–XX.]

14 April 2025 in Journal of Neurosurgery: Case Lessons
Verified
Journal Article
Open access
PDF file
LALaurie L. Ackerman
Laurie L. Ackerman
PGPatrick A. Gerety
Patrick A. Gerety
CBCharline Boente
Charline Boente
KHKathryn M. Haider
Kathryn M. Haider
MCMichael W. Chu
Michael W. Chu
STSunil S. Tholpady
Sunil S. Tholpady
BACKGROUND: Posterior cranial vault distraction osteogenesis (PVDO) is a commonly used cranial expansion procedure in infants and children with syndromic craniosynostosis. To date, there have been no reports of cranial nerve (CN) palsies in patients undergoing univector PVDO. OBSERVATIONS: In this article, the authors describe the case of a 27-month-old female with Muenke syndrome who underwent long-distance (> 30 mm) PVDO and developed bilateral abducens nerve (CN VI) palsy after 40 mm of distraction. Following partial reversal of the distraction during the activation phase, the authors observed complete resolution of this palsy. LESSONS: This report demonstrates that CN palsies are a potential complication for which the patient should be monitored, even when undergoing univector PVDO. Most notably, this report illustrates that a gradual reduction in the distraction distance can result in complete resolution of a CN VI palsy while also maintaining a significant degree of intracranial expansion. https://thejns.org/doi/10.3171/CASE24762