Representative Publications

View All Publications
16 January 2025 in Animals
Verified
Journal Article
Open access
PDF file
DDDANIELA Diagnostica Senese DIAMANTI
DANIELA Diagnostica Senese DIAMANTI
CPCarolina Pieroni
Carolina Pieroni
Maria Grazia PennisiMaria Grazia Pennisi
Maria Grazia Pennisi
Veronica MarchettiVeronica Marchetti
Veronica Marchetti
Eleonora GoriEleonora Gori
Eleonora Gori
GLGeorge Lubas
George Lubas
The erythrocyte sedimentation rate (ESR) measures the rate at which erythrocytes aggregate and sediment in a fixed time in an anticoagulated blood tube and is expressed as a speed (mm/h). The ESR is still widely used in human medicine mainly as a modified or alternate method to the original Westergren. In veterinary medicine, it was employed in the 1940s–1960s after which it was gradually abandoned or rarely employed. More papers using the Westergren method have been published in dogs rather than in cats. In recent years, the test has regained importance. This narrative review describes the principle of ESR, which is related to the increase in a few acute response proteins such as fibrinogen, immunoglobulin M, and α2-macroglobulin which act to aggregate RBCs. Reference intervals were established for dogs and cats for the original and modified Westergren method. The ESR is mainly used to detect inflammatory conditions derived from infection, urinary or orthopedic disorders, and also miscellaneous diseases. The application of the modified ESR is supported by appropriate reference intervals; however, further studies are needed to assess the influence of age, sex, and breed both for dogs and cats.

1 January 2023 in Veterinary Medicine International
Verified
Journal Article
Open access
PDF file
CPCarolina Pieroni
Carolina Pieroni
AGAndrea Grassi
Andrea Grassi
MPMarianna Pantoli
Marianna Pantoli
MBMirko Berretti
Mirko Berretti
SMStefano Messina
Stefano Messina
DDDANIELA Diagnostica Senese DIAMANTI
DANIELA Diagnostica Senese DIAMANTI
The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR values are associated with various disorders, including infections, rheumatoid arthritis, oncologic diseases, and other inflammatory conditions. The ESR can also be influenced by some factors such as age and gender. In veterinary medicine, the ESR with the Westergren manual method was almost forgotten over the years due to blood consumption and long turn‐around time. The instrument MINI‐PET, using a modified Westergren method, does not require blood consumption or release waste product and recently has been applied in canine medicine. The aims of the study in the horse were as follows: to establish the appropriate time to read the ESR with the Westergren reference method; to compare the MINI‐PET ESR results with the reference technique; to assess the ESR reference intervals with MINI‐PET; and to establish the ESR stability from collection at different time points by MINI‐PET. Using 150 horses, we established 60 minutes as the appropriate time for ESR reading with the Westergren method. Moreover, ESR results obtained in 8 minutes with MINI‐PET showed a good correlation with the Westergren ESR. Reference intervals (RIs) with MINI‐PET were established in mm/h for the healthy horses (geldings 18.6–100.1; stallions, 13.8–55.7; and mares 1–73.7) according to the American Society of Veterinary Clinical Pathology guidelines. In addition, the ESR stability from the blood collection time was evaluated in the MINI‐PET on 15 horses: at room temperature, ESR is stable up to 8 hours and at 4°C up to 24 hours. In conclusion, MINI‐PET represents a rapid and reliable tool for measuring ESR in horses, offering a valid option to replace the traditional manual technique.

8 May 2024 in Animals
Verified
Journal Article
Open access
PDF file
SPSaverio Paltrinieri
Saverio Paltrinieri
RFRoberta Ferrari
Roberta Ferrari
DSDonatella Scavone
Donatella Scavone
CPCarolina Pieroni
Carolina Pieroni
DDDANIELA Diagnostica Senese DIAMANTI
DANIELA Diagnostica Senese DIAMANTI
FTFilippo Tagliasacchi
Filippo Tagliasacchi
(1) Background: the erythrocyte sedimentation rate (ESR) has been reported to increase in some infectious or inflammatory diseases in dogs, but no information on the frequency of increases in a routine clinical setting exists. The aim of this study was to assess the frequency of an increased ESR in dogs and to investigate its possible association with hematologic changes; (2) Methods: A total of 295 EDTA blood samples were randomly selected from the routine caseload of the Veterinary Teaching Hospital. Samples were grouped in controls and in pathologic groups based on the clinical presentation. A routine hemogram was performed, then the ESR was measured using the instrument MINI-PET; (3) Results: compared with controls, the ESR was significantly higher in all the pathologic groups, except for the hematological disorders group. The highest ESR was found in samples from dogs with chronic kidney disease or inflammation, followed by those from dogs with mild chronic disorders, severe/acute diseases, tumors and urinary disorders. The ESR negatively correlated with hematocrit and positively with neutrophil counts. (4) Conclusions: The ESR increases more frequently in dogs with clinically evident inflammation or CKD, but also in several other conditions, likely as a consequence of anemia and acute phase response.

6 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MLMaria Lorubbio
Maria Lorubbio
DDDANIELA Diagnostica Senese DIAMANTI
DANIELA Diagnostica Senese DIAMANTI
AGAlessandro Ghiandai
Alessandro Ghiandai
CPCarolina Pieroni
Carolina Pieroni
DBDonatella Bonini
Donatella Bonini
AOAgostino Ognibene
Agostino Ognibene
The Erythrocyte Sedimentation Rate (ESR) is a diagnostic estimator of systemic inflammation as a reflection of acute phase proteins circulating in the blood. The purpose of this manuscript is to evaluate the blood stability at room temperature (RT) and at 4 °C to avoid ESR diagnostic errors, as well as the accuracy of the VES-MATIC 5 analyzer. The ESR stability evaluation at RT for 24 h (4 h “T1”, 6 h “T2”, 8 h “T3”, 10 h “T4”, 24 h “T5”) and at 4 °C (24 h, 36 h, 48 h) was carried out using 635 total samples, starting with T0 (2 h of venipuncture). For method comparison, 164 patients were analyzed using VES-MATIC 5 and then the Westergren reference method. The sample at RT is established by a significant gradual decrease in correlation R = 0.99 (T0 vs. T1), R = 0.97 (T0 vs. T2), R = 0.92 (T0 vs. T3), R = 0.87 (T0 vs. T4), and R = 0.40 (T0 vs. T5). The stability at 4 °C after 24 h, 36 h, and 48 h showed a regression of R = 0.99, R = 0.97, and R = 0.95, respectively. Therefore, ESR measurements on RT samples beyond 6 h after collection cannot be carried out, but the ESR can be measured until 36 h for samples stored at 4 °C. Moreover, the VES-MATIC 5 accuracy performance compared to the Westergren method (R = 0.96) is confirmed.

11 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
FTFlaminia Tomassetti
Flaminia Tomassetti
CCCinzia Calabrese
Cinzia Calabrese
Fabio BertaniFabio Bertani
Fabio Bertani
MCMichele Cennamo
Michele Cennamo
DDDANIELA Diagnostica Senese DIAMANTI
DANIELA Diagnostica Senese DIAMANTI
Massimo PieriMassimo Pieri
Massimo Pieri
Background: Erythrocyte Sedimentation Rate (ESR) is an easy test used to diagnose and monitor inflammatory and infectious diseases. The aim of this study was the evaluation of the performance of three ESR automated analyzers, VES-MATIC 5, CUBE 30 TOUCH, and MINI-CUBE, involving four Italian polyclinics in Rome, Siena, Como, and Arezzo, as well as inter-site variability assessment to detect possible device-dependent and operator-dependent influences. Methods: Accuracy analysis was carried out by analyzing the same samples with all three instruments and comparing them with the Westergren method. Precision was assessed with quality control material through intra-run and inter-run precision. Repeatability was estimated by reanalyzing fresh blood samples belonging to three ESR ranges (low, intermediate, and high) six times. Results: The results showed a strong correlation (Spearman coefficients R2) between the manual method and VES-MATIC 5 (0.978), CUBE 30 TOUCH (0.981), and MINI-CUBE (0.974). The accuracy of all clinics was excellent, with coefficients of variation (CVs) of less than 10% for all instruments. Repeatability confirmed an excellent level for all ESR ranges, with CVs below 10%. Conclusions: The study proved that all three automated instruments offer optimal performance for accuracy and precision and are suitable for both large and small facilities without influences of the laboratory environment.

1 January 2024 in Veterinary Medicine International
Verified
Journal Article
Open access
PDF file
Eleonora GoriEleonora Gori
Eleonora Gori
APAnna Pasquini
Anna Pasquini
SPSaverio Paltrinieri
Saverio Paltrinieri
GLGeorge Lubas
George Lubas
CMCarlo Militello
Carlo Militello
Veronica MarchettiVeronica Marchetti
Veronica Marchetti
The application of the erythrocyte sedimentation rate (ESR) in feline medicine is currently unavailable, while in canine medicine it has been rediscovered due to the introduction of an automated ESR device. Our aims were to (1) define the reference interval (RI) of the ESR in healthy cats, (2) evaluate the ESR values between healthy and ill cats, (3) evaluate relationships between the ESR and some inflammatory markers, and (4) assess ESR changes in different durations of illness (acute, chronic, or acute‐on‐chronic). A prospective multicentric cohort study on 200 client‐owned cats: 57 healthy cats and 143 ill cats for the other aims. Healthy cats were blood donors, or young cats underwent desexing procedures. Ill cats with full clinical medical records, hematobiochemical profiles, and diagnostic procedures to reach a final diagnosis were included. The ESR was performed with MINI‐PET using the same K3‐EDTA tubes used for CBC, with no additional sample required. The total leukocyte count (WBC), neutrophil‐to‐lymphocyte ratio (NLR), fibrinogen, serum amyloid A, and albumin/globulin ratio (A/G) were concurrently measured. Based on the clinical presentation and the final diagnosis, cats were classified as having the following: acute, chronic, and acute‐on‐chronic conditions. The RI of the ESR ranged between 1 and 23 mm/h. Ill cats showed a significantly higher ESR (median 29 mm/h; range 12–46 mm/h) than healthy cats (median 10 mm/h; range 1–12 mm/h; p < 0.0001). The ESR was positively correlated only with fibrinogen (p < 0.001; r = 0.43). Cats with acute‐on‐chronic diseases had the highest ESR (median 47 mm/h; range 35–56 mm/h) compared with acute (median 16 mm/h; range 14–42 mm/h; p = 0.003) and chronic cats (median 14 mm/h; range 10–31 mm/h; p < 0.0001). Although further studies are needed, the ESR could be a useful ancillary inflammatory marker in cats, specifically in cats with acute diseases, with or without an underlying chronic condition.