Lin Xu

Dr. Lin Xu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2022 in Experimental Cell Research
Verified
Journal Article
Closed access
JYJizhou Yang
Jizhou Yang
JGJian Gao
Jian Gao
FGFeng Gao
Feng Gao
YZYi Zhao
Yi Zhao
BDBowen Deng
Bowen Deng
LXLin Xu
Lin Xu

10 November 2017 in Polymers
Verified
Journal Article
Open access
PDF file
Jian SongJian Song
Jian Song
ZLZhenhua Liao
Zhenhua Liao
HSHongyu Shi
Hongyu Shi
XDXiang Dingding
Xiang Dingding
LXLin Xu
Lin Xu
Weiqiang LiuWeiqiang Liu
Weiqiang Liu
Titanium (Ti) and its alloys are widely used in biomedical devices. As biomaterials, the blood compatibility of Ti and its alloys is important and needs to be further improved to provide better functionality. In this work, we studied the suitability of zirconia (ZrO2) particle reinforced poly-ether-ether-ketone (PEEK) coatings on Ti6Al4V substrates for blood-contacting implants. The wettability, surface roughness and elastic modulus of the coatings were examined. Blood compatibility tests were conducted by erythrocytes observation, hemolysis assay and clotting time of recalcified human plasma, to find out correlations between the microstructure of the ZrO2-filled PEEK composite coatings and their blood compatibilities. The results suggested that adding ZrO2 nanoparticles increased the surface roughness and improved the wettability and Derjaguin-Muller-Toporov (DMT) elastic modulus of PEEK coating. The PEEK composite matrix coated Ti6Al4V specimens did not cause any aggregation of erythrocytes, showing morphological normal shapes. The hemolysis rate (HR) values of the tested specimens were much less than 5% according to ISO 10993-4 standard. The values of plasma recalcification time (PRT) of the tested specimens varied with the increasing amount of ZrO2 nanoparticles. Based on the results obtained, 10 wt % ZrO2 particle reinforced PEEK coating has demonstrated an optimum blood compatibility, and can be considered as a candidate to improve the performance of existing PEEK based coatings on titanium substrates.

30 November 2023 in Brain Research Bulletin
Verified
Journal Article
Open access
GLGang Liu
Gang Liu
BDBowen Deng
Bowen Deng
LHLuyao Huo
Luyao Huo
SJShengyuan Jiang
Shengyuan Jiang
XFXiao Fan
Xiao Fan
XMXiaohong Mu
Xiaohong Mu
Oxidative stress (OS) plays a pivotal role in the pathogenesis of spinal cord injury (SCI), yet its underlying mechanisms remain elusive. In this study, we explored the OS phenotype in a rat model of SCI. Subsequently, comprehensive bioinformatic analyses were conducted on microarray data pertaining to SCI (GSE45006). Notably, KEGG enrichment analysis revealed a pronounced enrichment of pivotal pathways, namely MAPK, FoxO, Apoptosis, NF-κB, TNF, HIF-1, and Chemokine across distinct phases of SCI. Furthermore, GO enrichment analysis highlighted the significance of biological processes including response to hypoxia, response to decrease oxygen levels, response to reactive oxygen species, cellular response to oxidative stress, reactive oxygen species metabolic process, and regulation of neuron death in the context of OS following SCI. Notably, our study underscores the prominence of nine genes, namely Itgb1, Itgam, Fn1, Icam1, Cd44, Cxcr4, Ptprc, Tlr4, and Tlr2 as OS key genes in SCI, consistently expressed in both the acute phase (1, 3, 7 days) and sub-acute phase (14 days). Subsequently, the relative mRNA expression of these key genes in different time points (1, 3, 7, 14 days) post-SCI. Finally, leveraging the DsigDB database, we predicted ten potential compounds potentially targeting OS and facilitating the repair of SCI, thus providing novel insights into the mechanisms underlying OS and identifying potential therapeutic targets for SCI.

1 January 2020
Verified
Journal Article
Closed access
CYC-H Yang
C-H Yang
WQW-L Qi
W-L Qi
CZC-W Zhao
C-W Zhao
WCW-J Cai
W-J Cai
QGQ. Gong
Q. Gong
LXLin Xu
Lin Xu