Two adaptive notch filters (ANFs) based on the double integrators (ANF R ) and the unbalanced synchronous reference frame control (ANF dq ) were applied to the bus voltage control of a single-phase grid-connected inverter. This article also proposes a non-invasive prognostic function for the degradation of the bus capacitance using the difference between the bus ripple amplitudes estimated from the ANFs and the dq -axes currents with the nominal bus capacitance. The ANF R , ANF dq , and conventional notch filters (NFs) were experimentally validated with a 220-V, 50-Hz, 2.5-kW two-stage inverter. The bus voltage control schemes using the three NFs tuned at a fast bandwidth of 30 Hz exhibited identical performance with the grid current harmonics complied with the IEEE 1547 standard. Moreover, the ANF R and ANF dq control schemes maintain low current distortion with a variable grid frequency of 45–55 Hz. The capacitance degradation prognostic function accurately responded to a 27% reduction in the bus capacitance. Considering the control performance and computational effort, the ANF R is suitable for bus voltage control of the single-phase inverter.
This paper presents a comprehensive analysis of the harmonic sources of the single-phase grid-connected voltage source converter (VSC), which leads to an alternative approach for DC bus voltage control of the VSC under grid voltage distortion with a significant switching dead time. A selective current harmonic controller with the zero-reference structure plays a vital role in rejecting the harmonic components in the grid reference current created by the bus voltage control loop and the harmonic components in the grid voltage and in the VSC caused by the switching dead time. Therefore, the bus voltage control can adopt a conventional proportional-integral regulator tuned at a fast bandwidth. The proposed control scheme implemented in the multiple unbalanced synchronous reference frames was validated with a bidirectional 2-kVA VSC under grid voltage distortion and a significant dead time. Furthermore, the proposed control scheme exhibited the transient response and grid current quality superior to the conventional bus voltage control methods with a notch filter and a low-pass filter. The proposed control scheme has inherent frequency adaption.
Integrating residential energy storage and solar photovoltaic power generation into low-voltage distribution networks is a pathway to energy self-sufficiency. This paper elaborates on designing and implementing a 3 kW single-phase grid-connected battery inverter to integrate a 51.2-V lithium iron phosphate battery pack with a 220 V 50 Hz grid. The prototyped inverter consists of an LCL-filtered voltage source converter (VSC) and a dual active bridge (DAB) DC-DC converter, both operated at a switching frequency of 20 kHz. The VSC adopted a fast DC bus voltage control strategy with a unified current harmonic mitigation. Meanwhile, the DAB DC-DC converter employed a proportional-integral regulator to control the average battery current with a dynamic DC offset mitigation of the medium-frequency transformer’s currents embedded in the single-phase shift modulation scheme. The control schemes of the two converters were implemented on a 32-bit TMS320F280049C microcontroller in the same interrupt service routine. This work presents a synchronization technique between the switching signal generation of the two converters and the sampling of analog signals for the control system. The prototyped inverter had an efficiency better than 90% and a total harmonic distortion in the grid current smaller than 1.5% at the battery power of ±1.5 kW.