In this work, the effect of ion bombardment on the optical properties of Polymethylmethacrylate (PMMA) was studied. Polymer samples were implanted with 500 keV Cu+ ions with a fluence ranging from 1 × 1012 to 1 × 1014 ions/cm2. X-ray Diffractometer (XRD) study indicated a relatively lower variation with a higher dose of ions. Fourier Transform Infrared (FTIR) spectra exhibited that with the implantation of Cu ions the intensity of existing bands decreases, while the result confirms the existence of a C=C group. The pristine and ion-implanted samples were also investigated using photoluminescence (PL) and Ultra Violet-Visible (UV-VIS) spectra. The optical band gap (Eg) was observed up to 3.05 eV for the implanted samples, while the pristine sample exhibited a wide energy-gap up to ~3.9 eV. The change in the optical gap indicated the presence of a gradual phase transition for the polymer blends. The dielectric measurements of the pristine and Cu-implanted PMMA were investigated in the 10 Hz to 2 GHz frequency range. It was found that the implanted samples showed a significant decrease in the value of the dielectric constant. The value of the dielectric constant and dielectric loss of the PMMA and Cu-implanted samples at a 1-kHz frequency were found to be ~300 and 29, respectively. The modification of the PMMA energy bandgap in the current research suggested the potential use of Cu implanted PMMA in the field of optical communications and flexible electronic devices.
Nitrogen ions were implanted on the Aluminum Alloy 7075-T6 to study the structural and mechanical properties. The implantation was carried out at energy 1 MeV with ion doses ranging from 8×1014, 1.2×1015 and 5.2×1015 ions/cm2. Structural analysis of all the samples was done by X-ray Diffractometer (XRD) for the implanted ions. Surface morphology of all the samples was studied by Scanning Electron Microscopy (SEM). Changes in the surface and structure are directly related to the dose of ion implantation. To understand the mechanical properties Universal Tensile Testing Machine was applied. Modifications in the crystalline structure of the material exhibit new properties to the lattice site. Effects on the crystallite size and stress generated by the damage strongly vary the yield stress, ultimate tensile strength and percentage elongation of the material. Hardness was tested by the Vickers Micro Hardness Tester. The result shows that the surface hardness obtained at room temperature by implanting nitrogen ions initially decreases and then systematically increases due to subsequent damage. Graph representing yield stress, ultimate tensile strength and hardness are strongly agreed with each other. The micro structure indicates the fractured surface after Tensile Test.
In the present work, the effect of hydrogen ion implantation on surface wettability and biocompatibility of stainless steel is investigated. Hydrogen ions are implanted in the near-surface of stainless steel to facilitate hydrogen bonding at different doses with constant energy of 500KeV, which consequently improve the surface wettability. Treated and untreated sample are characterized for surface wettability, incubation of hydroxyapatite and cell viability. Contact angle (CA) study reveals that surface wettability increases with increasing H- ion dose. Raman spectroscopy shows that precipitation of hydroxyapatite over the surface increase with increasing dose of H-ions. Cell viability study using MTT assay describes improved cell viability in treated samples as compared to the untreated sample. It is found that low dose of H-ions is more effective for cell proliferation and the cell count decreases with increasing ion dose. Our study demonstrates that H ion implantation improves the surface wettability and biocompatibility of stainless steel.
3 August 2017 in Radiation Effects and Defects in Solids
Stainless steel 306 is implanted with various doses of nitrogen ions using a 2 MV pelletron accelerator for the improvement of its surface biomedical properties. Raman spectroscopy reveals incubation of hydroxyapatite (HA) on all the samples and it is found that the growth of incubated HA is greater in higher ion dose samples. SEM profiles depict uniform growth and greater spread of HA with higher ion implantation. Human oral fibroblast response is also found consistent with Raman spectroscopy and SEM results; the cell viability is found maximum in samples treated with the highest (more than 300%) dose. XRD profiles signified greater peak intensity of HA with ion implantation; a contact angle study revealed hydrophilic behavior of all the samples but the treated samples were found to be lesser hydrophilic compared to the control samples. Nitrogen implantation yields greater bioactivity, improved surface affinity for HA incubation and improved hardness of the surface.
31 December 2022 in Journal of Materials and Physical Sciences
In this study, a novel method was adopted to tailor the surface properties of iron. We attempted to increase the degradation rate of iron by H-induced damaging. Equal number of H ions were implanted in four samples using a 2MV Pelletron accelerator. But the ion distribution was varied in the iron matrix by adding H ion layers in successively increasing depths. Interesting outcomes, contrary to our assumption were observed. The open-circuit potential was observed to shift toward a stable side. The Tefal plot also revealed improved corrosion potential and decreased corrosion current by adding H layers. Crystallographic studies revealed improved crystallinity and a small shift in preferred orientation of crystal growth.