Jessica Perea Houston

Dr. Jessica Perea Houston

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2020 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
KNKapil Nichani
Kapil Nichani
JLJianzhi Li
Jianzhi Li
MSMiho Suzuki
Miho Suzuki
JHJessica Perea Houston
Jessica Perea Houston
Caspase‐3 is a well‐described protease with many roles that impact the fate of a cell. During apoptosis, caspase‐3 acts as an executioner caspase with important proteolytic functions that lead to the final stages of programmed cell death. Owing to this key role, caspase‐3 is exploited intracellularly as a target of control of apoptosis for therapeutic outcomes. Yet the activation of caspase‐3 during apoptosis is challenged by other roles and functions (e.g., paracrine signaling). This brief report presents a way to track caspase‐3 levels using a flow cytometer that measures excited state fluorescence lifetimes and a signal processing approach that leads to a graphical phasor‐based interpretation. An established Förster resonance energy transfer (FRET) bioprobe was used for this test; the connected donor and acceptor fluorophore is cleavable by caspase‐3 during apoptosis induction. With the cell‐by‐cell decay kinetic data and phasor analyses we generate a caspase activation trajectory, which is used to interpret activation throughout apoptosis. When lifetime‐based cytometry is combined with a FRET bioprobe and phasor analyses, enzyme activation can be simplified and quantified with phase and modulation data. We envision extrapolating this approach to high content screening, and reinforce the power of phasor approaches with cytometric data. Analyses such as these can be used to cluster cells by their phase and modulation “lifetime fingerprint” when the intracellular fluorescent probe is utilized as a sensor of enzyme activity. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals LLC on behalf of International Society for Advancement of Cytometry.

4 September 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
HKHiroshi Kanno
Hiroshi Kanno
KHKotaro Hiramatsu
Kotaro Hiramatsu
HMHideharu Mikami
Hideharu Mikami
ANAtsushi Nakayashiki
Atsushi Nakayashiki
SYShota Yamashita
Shota Yamashita
KGKeisuke Goda
Keisuke Goda
Flow cytometry is a vital tool in biomedical research and laboratory medicine. However, its accuracy is often compromised by undesired fluctuations in fluorescence intensity. While fluorescence lifetime imaging microscopy (FLIM) bypasses this challenge as fluorescence lifetime remains unaffected by such fluctuations, the full integration of FLIM into flow cytometry has yet to be demonstrated due to speed limitations. Here we overcome the speed limitations in FLIM, thereby enabling high-throughput FLIM flow cytometry at a high rate of over 10,000 cells per second. This is made possible by using dual intensity-modulated continuous-wave beam arrays with complementary modulation frequency pairs for fluorophore excitation and acquiring fluorescence lifetime images of rapidly flowing cells. Moreover, our FLIM system distinguishes subpopulations in male rat glioma and captures dynamic changes in the cell nucleus induced by an anti-cancer drug. FLIM flow cytometry significantly enhances cellular analysis capabilities, providing detailed insights into cellular functions, interactions, and environments.

26 April 2021 in Frontiers in Physics
Verified
Journal Article
Open access
ABAric Bitton
Aric Bitton
JSJesus Sambrano
Jesus Sambrano
SVSamantha Valentino
Samantha Valentino
JHJessica Perea Houston
Jessica Perea Houston
Though much of the interest in fluorescence in the past has been on measuring spectral qualities such as wavelength and intensity, there are two other highly useful intrinsic properties of fluorescence: lifetime (or decay) and anisotropy (or polarization). Each has its own set of unique advantages, limitations, and challenges in detection when it comes to use in biological studies. This review will focus on the property of fluorescence lifetime, providing a brief background on instrumentation and theory, and examine the recent advancements and applications of measuring lifetime in the fields of high-throughput fluorescence lifetime imaging microscopy (HT-FLIM) and time-resolved flow cytometry (TRFC). In addition, the crossover of these two methods and their outlooks will be discussed.

1 October 2014 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
RCRuofan Cao
Ruofan Cao
MNMark A. Naivar
Mark A. Naivar
MWMark Wilder
Mark Wilder
JHJessica Perea Houston
Jessica Perea Houston
Fluorescence lifetime measurements provide information about the fluorescence relaxation, or intensity decay, of organic fluorophores, fluorescent proteins, and other inorganic molecules that fluoresce. The fluorescence lifetime is emerging in flow cytometry and is helpful in a variety of multiparametric, single cell measurements because it is not impacted by nonlinearity that can occur with fluorescence intensity measurements. Yet time‐resolved cytometry systems rely on major hardware modifications making the methodology difficult to reproduce. The motivation of this work is, by taking advantage of the dynamic nature of flow cytometry sample detection and applying digital signal processing methods, to measure fluorescence lifetimes using an unmodified flow cytometer. We collect a new lifetime‐dependent parameter, referred to herein as the fluorescence‐pulse‐delay (FPD), and prove it is a valid representation of the average fluorescence lifetime. To verify we generated cytometric pulses in simulation, with light emitting diode (LED) pulsation, and with true fluorescence measurements of cells and microspheres. Each pulse is digitized and used in algorithms to extract an average fluorescence lifetime inherent in the signal. A range of fluorescence lifetimes is measurable with this approach including standard organic fluorophore lifetimes (∼1 to 22 ns) as well as small, simulated shifts (0.1 ns) under standard conditions (reported herein). This contribution demonstrates how digital data acquisition and signal processing can reveal time‐dependent information foreshadowing the exploitation of full waveform analysis for quantification of similar photo‐physical events within single cells. © 2014 The Authors. Published by Wiley Periodicals, Inc.

19 October 2018 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
FAFaisal Alturkistany
Faisal Alturkistany
KNKapil Nichani
Kapil Nichani
KHKevin D. Houston
Kevin D. Houston
JHJessica Perea Houston
Jessica Perea Houston
Autofluorescence from the intracellular metabolite, NAD(P)H, is a biomarker that is widely used and known to reliably screen and report metabolic activity as well as metabolic fluctuations within cells. As a ubiquitous endogenous fluorophore, NAD(P)H has a unique rate of fluorescence decay that is altered when bound to coenzymes. In this work we measure the shift in the fluorescence decay, or average fluorescence lifetime (1–3 ns), of NAD(P)H and correlate this shift to changes in metabolism that cells undergo during apoptosis. Our measurements are made with a flow cytometer designed specifically for fluorescence lifetime acquisition within the ultraviolet to violet spectrum. Our methods involved culture, treatment, and preparation of cells for cytometry and microscopy measurements. The evaluation we performed included observations and quantification of the changes in endogenous emission owing to the induction of apoptosis as well as changes in the decay kinetics of the emission measured by flow cytometry. Shifts in NAD(P)H fluorescence lifetime were observed as early as 15 min post‐treatment with an apoptosis inducing agent. Results also include a phasor analysis to evaluate free to bound ratios of NAD(P)H at different time points. We defined the free to bound ratios as the ratio of ‘short‐to‐long’ (S/L) fluorescence lifetime, where S/L was found to consistently decrease with an increase in apoptosis. With a quantitative framework such as phasor analysis, the short and long lifetime components of NAD(P)H can be used to map the cycling of free and bound NAD(P)H during the early‐to‐late stages of apoptosis. The combination of lifetime screening and phasor analyses provides the first step in high throughput metabolic profiling of single cells and can be leveraged for screening and sorting for a range of applications in biomedicine. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.

16 January 2017 in Scientific Reports
Verified
Journal Article
Open access
WLWenyan Li
Wenyan Li
KHKevin D. Houston
Kevin D. Houston
JHJessica Perea Houston
Jessica Perea Houston
Phase-sensitive flow cytometry (PSFC) is a technique in which fluorescence excited state decay times are measured as fluorescently labeled cells rapidly transit a finely focused, frequency-modulated laser beam. With PSFC the fluorescence lifetime is taken as a cytometric parameter to differentiate intracellular events that are challenging to distinguish with standard flow cytometry. For example PSFC can report changes in protein conformation, expression, interactions, and movement, as well as differences in intracellular microenvironments. This contribution focuses on the latter case by taking PSFC measurements of macrophage cells when inoculated with enhanced green fluorescent protein (EGFP)-expressingE. coli. During progressive internalization of EGFP-E. coli, fluorescence lifetimes were acquired and compared to control groups. It was hypothesized that fluorescence lifetimes would correlate well with phagocytosis because phagosomes become acidified and the average fluorescence lifetime of EGFP is known to be affected by pH. We confirmed that average EGFP lifetimes consistently decreased (3 to 2 ns) with inoculation time. The broad significance of this work is the demonstration of how high-throughput fluorescence lifetime measurements correlate well to changes that are not easily tracked by intensity-only cytometry, which is affected by heterogeneous protein expression, cell-to-cell differences in phagosome formation, and number of bacterium engulfed.