This current study aimed to review the importance and assessment of corneal endothelium in terms of corneal transparency. The study revealed that the normal metabolic activity is necessary to maintain the temperature of the cornea, to renew its cells, to support the exchange processes of nutrients and to maintain its transparency. The endothelium is the inner layer of the cornea. The main function of the endothelium is to remove fluid from the corneal stroma, thus allowing the cornea to remain transparent. Younger patients recover relatively more easily after endothelial injury because they have a larger number of endothelial cells compared to older patients. Knowledge of the number and condition of endothelial cells are crucial for a number of decisions that the ophthalmic surgeon is called upon to make usually before surgery and Endothelial assessment health is a criterion for choosing a surgical method.
11 June 2020 in International Journal of Ophthalmology and Clinical Research
Contrast sensitivity (CS) expresses the quality of human vision. This article presents the main points for the interpretation of CS and what structures of the eye and brain contribute to achieving it. There is still information on the ways and types of CS clinical examination, factors and conditions affecting it, and the latest technological developments in its measurement.
2 October 2020 in Ophthalmology Research: An International Journal
Purpose: To compare central corneal thickness (CCT) measurements and their reproducibility when taken by Ultrasound Pachymetry, Ocular Biometry and Angiovue Optical Coherence Tomography (OCT). Methods: Twenty-five healthy volunteers were recruited creating a sample size of 50 eyes. All subjects had pachymetric measurements by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue). The measurements of central corneal thickness for the three devices were taken by the same examiner twice for more accuracy. Results: The average measurements of central corneal thickness by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue) were 547.26 μm, 551.36 μm, and 536.42 μm, respectively. The mean standard deviation (SD) of repeated measurements by Ocular biometry was 48.87 μm, which was greater than the mean SD of 44.24 μm and 40.35 μm (P < 0.001) by ultrasound pachymetry and Angiovue optical coherence tomography, respectively. There were statistically significant differences in the measurement results among the 3 methods (Ultrasound pachymetry vs. Ocular biometry P = 0.019; Ultrasound pachymetry vs. Angiovue Optical Coherence Tomography; P < 0.001; Ocular biometry vs. Angiovue Optical Coherence Tomography P < 0.001). There was a significant linear correlation between the Ultrasound pachymetry and Ocular biometry (r = 0.945, P<0.001), Ultrasound pachymetry and Angiovue Optical Coherence Tomography (r = 0.895, P<0.001), and Ocular biometry and Angiovue Optical Coherence Tomography (r = 0.902, P<0.001). Conclusion: Central corneal thickness readings were comparable between PachPen Handheld Pachymeter, IOL Master 700 Biometry and Angiovue Optical Coherence Tomography; Angiovue optical coherence tomography gave significantly smaller values. The measurements of the 3 methods showed significant linear correlations with one another. All methods provided acceptable repeatability of measurements.
1 January 1993 in Ophthalmic and Physiological Optics
Purpose: To compare measurements of axial length obtained with A-scan and IOL Master. The study was design to collect the axial length values resulting from the application of both methods on the same eye (R.E.) and then to compare them. Methodology Place and Duration of Study: 50 healthy patients selected randomly after visiting the clinic for daily routine examination. at the general hospital of Athens “Korgialenio – Benakio” were invited to participate in the study. The study took place in collaboration of University of West Attica Dept Biomedical Science Course Optics & Optometry with the general hospital of Athens “Korgialenio – Benakio”. Axial length measurements were obtained both by contact ultrasound (A‐scan 550 Sonomed, Lake Success, NY, USA) and by non‐contact laser interferometry (IOL Master 700 SWEPT Source Biometry). Two sets of measurements were repeated by a single examiner for each method. Results: A total of 50 eyes in 50 patients were evaluated. All participants volunteer to participate in this study. Estimates of axial length obtained with the two techniques were highly correlated. Axial lengths obtained with the contact method (mean 24.23mm, SD 1.64mm) were lower than those obtained with the non‐contact method (mean 23.29mm, SD 1.59mm) and the difference was not statistically significant (p = 0.150). The coefficient of variation was lower with non‐contact laser interferometry (6.58%) than with the ultrasound technique (6.76%). Conclusion: Similar estimates of axial length are obtained using contact and non‐contact techniques, with the latter producing higher measurements results than the former. The A-scan and the non‐contact laser interferometry device (IOL Master 700) provide both reproducible results with similar the accuracy of measurements of axial length in the clinical setting.