Purpose: To compare per-region macular sensitivity and delay from objective perimetry with Matrix perimetry and retinal thickness in mild diabetic macular edema (DMO). Methods: Thirty-three patients with type 2 diabetes (T2D) aged 59.2 ± 10.5 years participated in a longitudinal study. Macular thickness, sensitivities and delays from the objectiveFIELD Analyzer (OFA), and Matrix perimeter sensitivities were mapped onto a common spatial layout to compute per-region correlations between structure/function measures. A generalized linear mixed-effects logistic regression model determined which variables contributed to clinical diagnosis of DMO. Results: For OFA, the mean sensitivity differences compared with normal in patients with T2D were negative and the mean delay differences positive, indicating lowered sensitivities and prolonged delays, both increasing with diabetes duration. Shorter diabetes duration could produce either localized peripheral hypersensitivities or shorter delays. Functional change could occur when retinal thickness was stable. Peripheral macular thickness correlated with central and peripheral OFA sensitivity and delay, all P < 0.0012 in DMO and a median of P = 0.001 without DMO; this was not true for Matrix sensitivities. The logistic model determined that peripheral thickness, OFA sensitivity (P = 0.043), and time in the study (P = 0.001) contribute independently to the odds of DMO versus no DMO. Conclusions: Mean sensitivities decreased and mean delays increased with duration of diabetes. Peripheral macular thickness correlated significantly with central and peripheral macular OFA sensitivity and delay. Peripheral macular thickness and functional measures may provide sensitive prognostic data. Translational Relevance: Functional loss can precede structural change in DMO, so including such functional assessment for deciding on treatment may be beneficial.
Objective: Previous work on temporally sparse multifocal methods suggests that the results are correlated with disability and progression in people with multiple sclerosis (PwMS). Here, we assess the diagnostic power of three cortically mediated sparse multifocal pupillographic objective perimetry (mfPOP) methods that quantified response-delay and light-sensitivity at up to 44 regions of both visual fields concurrently. Methods: One high-spatial-resolution mfPOP method, P129, and two rapid medium-resolution methods, W12 and W20, were tested on 44 PwMS and controls. W12 and W20 took 82 s to test both visual fields concurrently, providing response delay and sensitivity at each field location, while P129 took 7 min. Diagnostic power was assessed using areas under the receiver operating characteristic (AUROC) curves and effect-size (Hedges’ g). Linear models examined significance. Concurrent testing of both eyes permitted assessment of between-eye asymmetries. Results: Per-region response delays and asymmetries achieved AUROCs of 86.6% ± 4.72% (mean ± SE) in relapsing–remitting MS, and 96.5% ± 2.30% in progressive MS. Performance increased with increasing disability scores, with even moderate EDSS 2 to 4.5 PwMS producing AUROCs of 82.1 to 89.8%, Hedge’s g values up to 2.06, and p = 4.0e − 13. All tests performed well regardless of any history of optic neuritis. W12 and W20 performed as well or better than P129. Conclusion: Overall, the 82-s tests (W12 and W20) performed better than P129. The results suggest that mfPOP assesses a correlate of disease severity rather than a history of inflammation, and that it may be useful in the clinical management of PwMS.
By measuring insect compensatory optomotor reflexes to visual motion, researchers have examined the computational mechanisms of the motion processing system. However, establishing the spectral sensitivity of the neural pathways that underlie this motion behavior has been difficult, and the contribution of the simple eyes (ocelli) has been rarely examined. In this study we investigate the spectral response properties and ocellar inputs of an anatomically identified descending neuron (DNII2) in the honeybee optomotor pathway. Using a panoramic stimulus, we show that it responds selectively to optic flow associated with pitch rotations. The neuron is also stimulated with a custom-built light-emitting diode array that presented moving bars that were either all-green (spectrum 500–600 nm, peak 530 nm) or all-short wavelength (spectrum 350–430 nm, peak 380 nm). Although the optomotor response is thought to be dominated by green-sensitive inputs, we show that DNII2is equally responsive to, and direction selective to, both green- and short-wavelength stimuli. The color of the background image also influences the spontaneous spiking behavior of the cell: a green background produces significantly higher spontaneous spiking rates. Stimulating the ocelli produces strong modulatory effects on DNII2, significantly increasing the amplitude of its responses in the preferred motion direction and decreasing the response latency by adding a directional, short-latency response component. Our results suggest that the spectral sensitivity of the optomotor response in honeybees may be more complicated than previously thought and that ocelli play a significant role in shaping the timing of motion signals.
13 November 2019 in Graefe's Archive for Clinical and Experimental Ophthalmology
Purpose: To inform national health policy, we quantified the pattern of neuro-ophthalmological disorders (NODs) presenting to the national vitreoretinal clinics in Bhutan. Study Design: Retrospective cross-sectional study. Methods: We reviewed all new NODs patients over three years. Demographic data, presenting complaints, treatment history, systemic diseases, diagnostic procedures, and diagnoses were quantified. Logistic regression examined the odds of factors linked to more common NODs. Results: Of 226 patients, the majority were males (54.0%), farmers (60.2%), and urbanites (55.8%). Loss of vision was the most common presenting complaint (57.9%), followed by head or orbital trauma (19.5%). The best corrected visual acuity (BCVA) of 216 eyes (47.8%) was ≤ 6/60. Hypertension was the most common systemic disease (16.4%), followed by diabetes (3.5%), and intracranial space-occupying lesions (3.5%). Neuroimaging (37.6%) was the most common diagnostic test performed, followed by visual field testings (VFTs) (22.9%). With a NOD incidence of 7.8% p.a. (226/2913), optic atrophy (OA) was diagnosed in 134 patients (59.3%). Other common NODs were optic neuritis (15.5%), papilloedema (9.3%), and traumatic optic neuropathy (8.4%). Female gender increased the odds for glaucomatous OA by 2.65× (p = 0.044), and age by 1.09× per year (p < 0.001). Being female increased the odds of optic neuritis by 2.57× (p = 0.03). Conclusion: Over half of the NODs were OA, which could be curable with timely treatment. Improved treatment of glaucoma and non-communicable diseases would reduce the risk of NODs-induced visual loss in Bhutan. The need for improved neuro-ophthalmological assessment and a coordinated multidisciplinary approach to NODs are the highest priorities.
14 March 2024 in Graefe's Archive for Clinical and Experimental Ophthalmology
Purpose: To compare diagnostic power for different severities of age-related macular degeneration (AMD) of two-dimensional macular pigment optical densities (2D-MPOD) and spatially matched objective perimetry, with standard perimetry and best-corrected visual acuity (BCVA). Methods: The ObjectiveField Analyser (OFA) provided objective perimetry, and a Heidelberg Spectralis optical coherence tomography (OCT) measured 2D-MPOD in AMD patients, both completed twice over 0.99 ± 0.16 years. From each 2D-MPOD image, we extracted 20 regions/macula, matched to the 20 OFA stimuli/macula. For each region, we calculated 7 measures from the 2D-MPOD pixel values and correlated those with OFA sensitivities and delays. We quantified 2D-MPOD changes, the ability of 2D-MPOD and OFA to discriminate AMD stages, and the discriminatory power of Matrix perimetry and BCVA using percentage area under receiver operator characteristic plots (%AUROC). Results: In 58 eyes of 29 subjects (71.6 ± 6.3 years, 22 females), we found significant correlations between 2D-MPOD and OFA sensitivities for Age-Related Eye Disease Studies (AREDS)-3 and AREDS-4 severities. Delays showed significant correlations with AREDS-2. For AREDS-4, correlations extended across all eccentricities. Regression associated with the Bland–Altman plots showed significant changes in 2D-MPOD over the study period, especially variability measures. MPOD per-region medians discriminated AREDS-1 from AREDS-3 eyes at a %AUROC of 80.0 ± 6.3%, outperforming OFA, Matrix perimetry, and BCVA. Conclusions: MPOD changes correlated with central functional changes and significant correlations extended peripherally in later-stage AMD. Good diagnostic power for earlier-stage AMD and significant change over the study suggest that 2D-MPOD and OFA may provide effective biomarkers.