Kyung-Joo Cho

Ms. Kyung-Joo Cho


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
KCKyung-Joo Cho
Kyung-Joo Cho
DCDongwoo Cho
Dongwoo Cho
BKBokyoung Koo
Bokyoung Koo
YYyosun yun
yosun yun
Windows in new buildings in Korea are equipped with double or triple glazing, a low-E coating, and gas injection between the panes of glass, in accordance with the regulations for the reinforced insulation of windows. However, these windows have certain issues, such as thermal transmittance variations and injected gas leakage. In this study, we investigated the current status of double-glazed windows filled with argon gas and analyzed the actual deterioration degree in terms of insulation performance via field experiments and simulations. Accordingly, we manufactured a 26-millimeter low-E double-glazed window test specimen and conducted tests in accordance with the KS F 2278 standard. The test results indicated that the thermal performance decreased by 10.9% when the argon gas filling rate was reduced from 95% to 0%. The simulation results showed that the thermal performance of windows that were insulated using only glazing decreased by 22.6% with the decrease in the argon gas filling rate; the thermal performance of the double-glazed windows also decreased by 13.6%. A comprehensive analysis of the field surveys and simulations predicted a 92% probability that the argon gas filling rate of double-glazed windows would be below 65% by two years after completion, in addition to a ~4.3% decrease in thermal performance.

27 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
KAKi Uhn Ahn
Ki Uhn Ahn
DKDeuk-Woo Kim
Deuk-Woo Kim
KCKyung-Joo Cho
Kyung-Joo Cho
DCDongwoo Cho
Dongwoo Cho
HCHyun Mi Cho
Hyun Mi Cho
CCChang-U Chae
Chang-U Chae
Indoor CO2 concentration is considered a metric of indoor air quality that affects the health of occupants. In this study, a hybrid model was developed for forecasting the varying indoor CO2 concentration levels in a residential apartment unit in the presence of occupants by controlling the ventilation rates of a heat recovery ventilator. In this model, the mass balance equation for a single zone as a white-box model was combined with a Bayesian neural network (BNN) as a black box model. During the learning process of the hybrid model, the BNN estimated an aggregated unknown ventilation rate and transferred the estimation to the mass-balance equation. A parametric study was conducted by changing the prediction horizons of the hybrid model from 5 to 15 min, and the forecasting performance of the hybrid model was compared with the stand-alone mass balance equation. The hybrid model showed better forecasting performance than that of the mass balance equation on the experimental dataset for a living room and bedroom. The average MBE and CVRMSE of the hybrid model for the prediction horizon of 15 min were 0.65% and 5.23%, respectively, whereas those of the mass balance equation were 0.99% and 9.30%, respectively.

3 January 2018 in Energies
Verified
Journal Article
Open access
PDF file
KCKyung-Joo Cho
Kyung-Joo Cho
DCDongwoo Cho
Dongwoo Cho
Double skin facade systems are known to be capable of preventing overheating in curtain wall buildings to a certain degree. The system induces the efficient blocking of sunlight using a center blind during the summer season. Moreover, it enables overheated air in the cavity layer to be sent outdoors, resulting in a reduction of the use of energy for cooling. However, double skin facade systems can be problematic, in that they must be opened according to seasonal conditions to achieve greater energy consumption efficiencies. In current double skin facade systems, the width of the cavity layer was too wide for residents to easily operate the system. When considering this, research on an easy-to-open 270 mm slim-type double skin window (SDSW) was undertaken in order to confirm its energy efficient performance. First, official testing based on the KS L 9107 Standard was undertaken to analyze solar heat gain coefficients (SHGC) and the cavity air temperatures, according to the open and close conditions of the SDSW’s external windows, enabling an analysis of the effect that the opening of windows had on reducing cooling energy needs. Next, SHGCs and cavity air temperatures were studied according to the different opening conditions of the SDSW’s external window to analyze the most optimal effects on cooling energy reductions by Computational Fluid Dynamics (CFD).

31 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
JJJinhee Jeong
Jinhee Jeong
KCKyung-Joo Cho
Kyung-Joo Cho
The public interest in indoor air quality has rapidly increased in Korean society, and ventilation systems can play an essential role in improving indoor air quality. This study aims to estimate the reduction in indoor CO2 and radon, which can be effectively mitigated by air exchange, according to the operation of mechanical ventilation in an apartment with the national standard housing size (85 m2) and shape in Korea. The time required to meet Korea’s mandatory indoor CO2 standard (1000 ppm) was 167, 98, 66, and 51 min under air change rates of 0.5, 1.0, 1.5, and 2.0 ACH (air change per hour), respectively. Regarding indoor radon, the removal rate increased with increased ventilation volume, and the minimum concentration level was low and sustained for a prolonged duration. Nonetheless, an air change rate of 0.5 ACH may not offer sufficient ventilation. Additionally, it is imperative to note that indoor radon concentrations tend to escalate swiftly when a mechanical ventilation system is deactivated. Thus, to enhance indoor air quality, it is necessary to reconsider strategies to augment the air change rate and guarantee uninterrupted ventilation.

9 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
KCKyung-Joo Cho
Kyung-Joo Cho
DCDongwoo Cho
Dongwoo Cho
TKTaeyoen Kim
Taeyoen Kim
This study makes a novel attempt to analyse the effect of the bypass control and room control modes on ventilation energy saving in an 84 m2 housing unit, which is the most frequently constructed unit-type among newly constructed apartment buildings in Korea. A heat recovery ventilation system was installed. The fan power consumption was measured via field experiments and analyses were made for potential energy savings. Experiments to confirm the power-saving effect owing to the application of the room control mode were performed under the heat recovery and bypass modes, using three air flow rates (0.5, 1.0 and 1.5 ACH). Additionally, the annual energy saving based on the application of the mixed mode (both bypass and room control modes) was calculated. The results obtained showed that when the mixed mode was employed, ventilation energy saving up to 10.76%–16.56%, which is greater than that obtained using only the heat recovery mode, was realized. Additionally, compared with all-room-ventilation, 26.69%–61.84% of ventilation energy could be saved if the mixed mode was applied only to the living room.

15 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
KCKyung-Joo Cho
Kyung-Joo Cho
DCDongwoo Cho
Dongwoo Cho
TKTaeyoen Kim
Taeyoen Kim
Korean law requires at least three levels of control for apartment ventilation systems, including 0.5 air change per hour (ACH). When this law was enacted, it was believed that a 0.5 ACH air flow rate would be sufficient for apartments following building completion. However, ventilation systems cause different air qualities in each space within a unit, depending on infiltration rate and number of occupants. In addition, the current ventilation rate standard is based on an apartment unit’s total area, assuming that all room doors are open. In this study, changes in CO2 concentration were experimentally analyzed based on the number of occupants and various ventilation frequencies with closed doors to analyze air quality differences among rooms in a typical 85 m2 apartment unit in Korea. When the 0.5 ACH ventilation was performed, maintaining 1000 ppm or less was difficult if four people stayed for more than two hours in the living room or two people stayed for more than one hour in the bedroom with closed doors. Our results indicate that it is challenging to maintain a CO2 concentration of 1000 ppm when doors are closed as standards are calculated based on a unit’s total area. Therefore, ventilation systems should be required to provide different air volumes for each room.