Hongzhen Cui

Dr. Hongzhen Cui

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2025 in Algorithms
Verified
Journal Article
Open access
PDF file
HCHongzhen Cui
Hongzhen Cui
SNShenhui shen Ning
Shenhui shen Ning
SWShichao Wang
Shichao Wang
WZWei Zhang
Wei Zhang
PYPeng Yunfeng
Peng Yunfeng
To address the need for accurate classification of electrocardiogram (ECG) signals, we employ an interpretable KAN to classify arrhythmia diseases. Experimental evaluation of the MIT-BIH and PTB datasets demonstrates the significant superiority of the KAN in classifying arrhythmia diseases. Specifically, preprocessing steps such as sample balancing and variance sorting effectively optimized the feature distribution and significantly enhanced the model’s classification performance. In the MIT-BIH, the KAN achieved classification accuracy and precision rates of 99.08% and 99.07%, respectively. Similarly, on the PTB dataset, both metrics reached 99.11%. In addition, experimental results indicate that compared to the traditional multi-layer perceptron (MLP), the KAN demonstrates higher classification accuracy and better fitting stability and adaptability to complex data scenarios. Applying three clustering methods demonstrates that the features extracted by the KAN exhibit clearer cluster boundaries, thereby verifying its effectiveness in ECG signal classification. Additionally, convergence analysis reveals that the KAN’s training process exhibits a smooth and stable loss decline curve, confirming its robustness under complex data conditions. The findings of this study validate the applicability and superiority of the KAN in classifying ECG signals for arrhythmia and other diseases, offering a novel technical approach to the classification and diagnosis of arrhythmias. Finally, potential future research directions are discussed, including the KAN in early warning and rapid diagnosis of arrhythmias. This study establishes a theoretical foundation and practical basis for advancing interpretable networks in clinical applications.

27 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
XTXingyi Tang
Xingyi Tang
YWYan Wang
Yan Wang
HMHaoming Ma
Haoming Ma
AWAoqi Wang
Aoqi Wang
YZYou Zhou
You Zhou
MPMeihua Piao
Meihua Piao
High-quality cardiopulmonary resuscitation (CPR) and training are important for successful revival during out-of-hospital cardiac arrest (OHCA). However, existing training faces challenges in quantifying each aspect. This study aimed to explore the possibility of using a three-dimensional motion capture system to accurately and effectively assess CPR operations, particularly about the non-quantified arm postures, and analyze the relationship among them to guide students to improve their performance. We used a motion capture system (Mars series, Nokov, China) to collect compression data about five cycles, recording dynamic data of each marker point in three-dimensional space following time and calculating depth and arm angles. Most unstably deviated to some extent from the standard, especially for the untrained students. Five data sets for each parameter per individual all revealed statistically significant differences (p < 0.05). The correlation between Angle 1′ and Angle 2′ for trained (rs = 0.203, p < 0.05) and untrained students (rs = −0.581, p < 0.01) showed a difference. Their performance still needed improvement. When conducting assessments, we should focus on not only the overall performance but also each compression. This study provides a new perspective for quantifying compression parameters, and future efforts should continue to incorporate new parameters and analyze the relationship among them.

28 April 2025 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
HCHongzhen Cui
Hongzhen Cui
XZXiaoyue Zhu
Xiaoyue Zhu
WZWei Zhang
Wei Zhang
MPMeihua Piao
Meihua Piao
PYPeng Yunfeng
Peng Yunfeng
Background: Cardiovascular diseases are diverse, intersecting, and characterized by multistage complexity. The growing demand for personalized diagnosis and treatment poses significant challenges to clinical diagnosis and pharmacotherapy, increasing potential medication risks for doctors and patients. The Cardiovascular Medication Guide (CMG) demonstrates distinct advantages in managing cardiovascular disease, serving as a critical reference for front-line doctors in prescription selection and treatment planning. However, most medical knowledge remains fragmented within written records, such as medical files, without a cohesive organizational structure, leading to an absence of clinical support from visualized expert knowledge systems.Purpose: This study aims to construct a comprehensive Expert Knowledge Graph of Cardiovascular Medication Guidelines (EKG-CMG) by integrating unstructured and semi-structured Cardiovascular Medication Knowledge (CMK), including clinical guidelines and expert consensus, to create a visually integrated cardiovascular expert knowledge system.Methods: This study utilized consensus and guidelines from cardiovascular experts to organize and manage structured knowledge. BERT and knowledge extraction techniques capture drug attribute relationships, leading to the construction of the EKG-CMG with fine-grained information. The Neo4j graph database stores expert knowledge, visualizes knowledge structures and semantic relationships, and supports retrieval, discovery, and reasoning of knowledge about medication. A hierarchical-weighted, multidimensional relational model to mine medication relationships through reverse reasoning. Experts participated in an iterative review process, allowing targeted refinement of expert medication knowledge reasoning.Results: We construct an ontology encompassing 12 cardiovascular “medication types” and their “attributes of medication types”. Approximately 15,000 entity-relationships include 22,475 medication entities, 2,027 entity categories, and 3,304 relationships. Taking beta-blockers (β) as an example demonstrates the complete process of ontology to knowledge graph construction and application, encompassing 41 AMTs, 1,197 entity nodes, and 1,351 relationships. The EKG-CMG can complete knowledge retrieval and discovery linked to “one drug for multiple uses,” “combination therapy,” and “precision medication.” Additionally, we analyzed the knowledge reasoning case of cross-symptoms and complex medication for complications.Conclusion: The EKG-CMG systematically organizes CMK, effectively addressing the “knowledge island” issues between diseases and drugs. Knowledge potential relationships have been exposed by leveraging EKG-CMG visualization technology, which can facilitate medication semantic retrieval and the exploration and reasoning of complex knowledge relationships.

23 June 2025 in Applied Intelligence
Verified
Journal Article
Closed access
PDF file
HCHongzhen Cui
Hongzhen Cui
SWShichao Wang
Shichao Wang
HMHaoming Ma
Haoming Ma
XZXiaoyue Zhu
Xiaoyue Zhu
LZLonghao Zhang
Longhao Zhang
YPYunfeng Peng
Yunfeng Peng

10 November 2025 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
HCHongzhen Cui
Hongzhen Cui
MPMeihua Piao
Meihua Piao
YDYiying Dong
Yiying Dong
YPYunfeng Peng
Yunfeng Peng

21 August 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XZXiaoyue Zhu
Xiaoyue Zhu
HCHongzhen Cui
Hongzhen Cui
LZLonghao Zhang
Longhao Zhang
GZGuilong Zhang
Guilong Zhang
SNShenhui Ning
Shenhui Ning
PYPeng Yunfeng
Peng Yunfeng
This study aims to develop and evaluate an Optical Character Recognition (OCR)-based system to identify and extract Diagnosis-Related Groups (DRG)- related data to facilitate manual entry. This study represents a controlled experimental analysis based on data derived from the Home Page of Medical Records (HPMRs). We developed DRG-AIE (DRG-Automatic Identification and Extraction), a novel system based on PaddleOCR. The control experiment included 20 participants with medical backgrounds. This study reports on the time and accuracy of data identification and extraction, as well as participants’ subjective feedback on DRG-AIE. DRG-AIE reduced entry time by an average of 53.27% per HPMR (71.80 [95% CI: 57.30–99.60] seconds, P < 0.01). The character and field accuracy are 99.36–98.97%, and the corresponding error rates are below the acceptable upper limits. Within different HPMR types, DRG-AIE also achieved significant time savings and an acceptable error rate. Participants’ subjective feedback on DRG-AIE was positive, and all participants indicated that they would recommend it to peers. DRG-AIE significantly accelerates and simplifies manual entry without compromising accuracy. It allows coders to focus on code review, HPMRs quality control, and medical insurance compliance checks. The DRG report it generates improves the verification of medical insurance payment evidence and the identification of payment risk violations.