Jayanthi Thiruvengadam

Jayanthi Thiruvengadam


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of Medical Physics
Verified
Journal Article
Open access
PDF file
MAM Anburajan
M Anburajan
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
MMM Menaka
M Menaka
BVB Venkatraman
B Venkatraman
Vascular dysfunction is associated with onset of cardiovascular disease (CVD). Its effect is reflected as temperature change on the skin. The aim of this work was to test the potential of thermal imaging as cost effective screening tool for prediction of CVD. Thermal imaging of various parts of the subject (N = 80, male/female =44/36, aged 25-75 years) was done using noncontact infrared (IR) camera. In each subject, total cholesterol (TC; mg/dl) and high-density lipoprotein (HDL, mg/dl) were measured according to standard biochemical analysis. Based on National Cholesterol Education Program ATP III criteria, subject with known CVD (N = 16) and age- and sex- matched normal subjects (N = 21) were included in the study. The average surface temperature of various parts from head to toe was calculated and statistical analysis was performed between the groups. In the total population (N = 37), correlation study shows TC (mg/dl) was correlated with measured surface temperature of the following regions: Temporal left (r = −0.316) and right (r = −0.417), neck left (r = 0.347) and right (r = −0.410), and hand left (r = 0.387). HDL (mg/dl) was found to be correlated with measured surface temperature of the following regions: Temporal left (r = 0.445) and right (r = 0.458), hand left (r = −0.470), and foot anterior left (r = −0.332) and right (r = −0.336). Temperature asymmetry was more significant in upper extremity in CVD group. Using the surface temperature, regression models were calculated for noninvasive estimation of TC and HDL. The predictive ability of measured surface temperature for TC and HDL was 60%. The model for noninvasive estimation gave sensitivity and specificity value of 79 and 83% for TC and 78 and 81% for HDL, respectively. Thus, the surface temperature can be one of the screening tools for prediction of CVD. The limitation of the present study is also discussed under future work.

23 May 2025 in Infrastructures
Verified
Journal Article
Open access
PDF file
BRBalamaheshwaran RENGANATHAN
Balamaheshwaran RENGANATHAN
RPRadhakrishnan Shanthi Priya
Radhakrishnan Shanthi Priya
GKGeetha K
Geetha K
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
Ramalingam SenthilRamalingam Senthil
Ramalingam Senthil
The conceptual design phase in architecture requires both intuitive and iterative approaches, which traditional Building Information Modeling (BIM) workflows fail to support properly. BIM provides data-driven decision-making and project coordination but does not offer affective or experiential feedback capabilities. BIM and Virtual Reality (VR) integration offers a promising solution to improve user-focused spatial assessments during initial design phases. The research follows three distinct phases, including a Systematic Literature Review to identify BIM-based conceptual workflow limitations, semi-structured interviews with architects to understand practical challenges and expectations, and the development of a BIM-based framework combining immersive VR for affective and visuospatial evaluation. A testing phase of the proposed framework occurred in the pilot study. The current BIM workflows show significant deficiencies in their ability to support creative flexibility, user engagement, and experiential validation. The BIM-VR framework implemented in the pilot study showed improvements in spatial cognition, emotional engagement, and iterative design decision-making during the conceptual design phase. Early-stage architectural design evaluation becomes more effective through VR integration into BIM workflows because it provides real-time immersive user feedback. The proposed framework helps develop BIM tools that are more intuitive for humans while advancing user-informed design practices in the architecture, engineering, and construction industries.
1

16 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DJDelpha Jacob
Delpha Jacob
PKPriyanka Kokil
Priyanka Kokil
SSSubramanian Suriyan
Subramanian Suriyan
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
Repeated breath cessation during sleep due to the closure of the airway passage is a condition known as obstructive sleep apnea (OSA). Untreated OSA elevates occupational-related fatal incidents, motor vehicle accidents, severe depression, cardiac and cerebrovascular ailments, and reduced survival expectancy. The gold standard for diagnosing OSA is polysomnography (PSG), which is an overnight sleep study. PSG is associated with higher costs and relative discomfort for the subject. In this work, a dedicated device is designed and developed to screen the individual for probable OSA. The proposed device incorporates a pressure sensor and an Arduino Nano 33 BLE Sense controller to capture the respiratory pressure signals the subject generates. An algorithm is developed to calculate essential breath metrics that include parameters such as the respiratory rate (RR), the inspiratory time (It), the expiratory time (Et) and the Apnea-Hypopnea Index (AHI). These metrics serve as indicators to grade and assess the likelihood of OSA in the subject. Additionally, the proposed system also monitors the sleeping position of the subject, temperature, and humidity as supplementary parameters to evaluate their sleep patterns comprehensively during the study. The proposed methodology offers a direct and efficient means of measuring respiratory signals for OSA assessment, thereby eliminating the need for extensive overnight sleep studies and complex multi-parameter analyses. The proposed method also allows individuals to sleep naturally without the requirement for physical restraints during monitoring, as in traditional method. This approach holds promise for more convenient and accessible OSA screening while simultaneously enabling parallel monitoring through the CPAP mask.

20 September 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
DJDelpha J
Delpha J
PKPriyanka Kokil
Priyanka Kokil
SSSubramaniyan S
Subramaniyan S
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
Obstructive sleep apnea (OSA) is a sleep disorder for which continuous positive airway pressure (CPAP) therapy is an effective treatment. In this study, a novel method to control the pressure in the positive airway pressure (PAP) device is proposed, this, in return, reduces the need to keep the subject at high pressure throughout extended period of their sleep without hindering the efficacy of the therapy. A standard CPAP/Bi-PAP (Bi-level Positive Airway Pressure) titration study is compared and verified with the predicted pressure values. Also the relationship and correlation between weight, age, SpO 2 , oxygen desaturation index (ODI), and the maximum pressure required for PAP therapy are also analyzed. Thus it is affirmed that, the PAP therapy compliance can be improved by sustaining the essential pressure and avoiding extended high-pressure intervals during therapy, unless they are absolutely required.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
SKS. P. Angeline Kirubha
S. P. Angeline Kirubha
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
SSSai Tejveer Santhan
Sai Tejveer Santhan
JIJishna
Jishna
The human heart beats rhythmically, maintaining a steady beat to pump blood across the body. This constant beating is also required to maintain the vessel blood pressure, preventing circulatory collapse and subsequently ischemia or infarction. Arrhythmia or irregular rhythm, due to a pre-existing condition or damage to the heart’s neuromuscular structure, can lead to a change in the heart rate and the flow pressure in the blood vessels. In resolvable or temporary arrhythmia, the therapeutic procedure of choice remains synchronized cardioversion. Cardioversion, a procedure akin to defibrillation, essentially involves reconfiguring the heart’s electrical system by delivering a calculated charge of electric current at the appropriate junction in the cardiac rhythm. However, if performed unnecessarily or incorrectly, cardioversion can result in arrhythmia or cardiac arrest. Thus in cases requiring the utilization of this protocol, it is of vital importance to monitor the patient’s cardiac rhythm and deliver the cardioversive shock only at the appropriate juncture. This paper reviews the various techniques utilized to track and deliver cardioversion.

1 November 2024 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
BBB Abira Bright
B Abira Bright
VDVani Damodaran
Vani Damodaran
JTJayanthi Thiruvengadam
Jayanthi Thiruvengadam
Tissue phantoms play an important role in validating biomedical imaging techniques. For optical imaging systems such as optical coherence tomography, creating layers of phantoms with different refractive indices is important. This paper explored various phantom materials to create eye-mimicking phantoms. The phantom also included microfluidic channels to mimic vasculature. To verify the optical properties of the created phantom, the transmission and reflection spectroscopy was performed using a photoluminescent spectrometer studying the complete visible and near infrared spectrum. We created a 3D model to house multiple layers that mimicked the retina at one end and the contact lens at the other, representing the anterior segment of the eye. A realistic retinal layer-mimicking, which, among other things, may pave the way for new combined imaging modalities