Mesbah Alam

Dr. Mesbah Alam

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Behavioural Brain Research
Verified
Journal Article
Closed access
CWChristof von Wrangel
Christof von Wrangel
KSKerstin Schwabe
Kerstin Schwabe
NJNadine John
Nadine John
JKJoachim K. Krauss
Joachim K. Krauss
MAMesbah Alam
Mesbah Alam

1 August 2014 in Journal of Neural Transmission
Verified
Journal Article
Closed access
PDF file
MAMesbah Alam
Mesbah Alam
KSKerstin Schwabe
Kerstin Schwabe
GLGötz Lütjens
Götz Lütjens
HCH. Holger Capelle
H. Holger Capelle
MMMihai Manu
Mihai Manu
JKJoachim K. Krauss
Joachim K. Krauss

23 November 2015 in Journal of Neural Transmission
Verified
Journal Article
Closed access
PDF file
MAMesbah Alam
Mesbah Alam
MSM. K. Sanghera
M. K. Sanghera
KSK. Schwabe
K. Schwabe
GLG. Lütjens
G. Lütjens
XJX. Jin
X. Jin
JKJoachim K. Krauss
Joachim K. Krauss

12 January 2016 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
SASvilen D. Angelov
Svilen D. Angelov
SKSven Koenen
Sven Koenen
JJJurij Jakobi
Jurij Jakobi
HHHans E. Heissler
Hans E. Heissler
MAMesbah Alam
Mesbah Alam
JKJoachim K. Krauss
Joachim K. Krauss
Electrodes for neural stimulation and recording are used for the treatment of neurological disorders. Their features critically depend on impedance and interaction with brain tissue. The effect of surface modification on electrode impedance was examined in vitro and in vivo after intracranial implantation in rats. Electrodes coated by electrophoretic deposition with platinum nanoparticles (NP; <10 and 50 nm) as well as uncoated references were implanted into the rat’s subthalamic nucleus. After postoperative recovery, rats were electrostimulated for 3 weeks. Impedance was measured before implantation, after recovery and then weekly during stimulation. Finally, local field potential was recorded and tissue-to-implant reaction was immunohistochemically studied. Coating with NP significantly increased electrode’s impedance in vitro. Postoperatively, the impedance of all electrodes was temporarily further increased. This effect was lowest for the electrodes coated with particles <10 nm, which also showed the most stable impedance dynamics during stimulation for 3 weeks and the lowest total power of local field potential during neuronal activity recording. Histological analysis revealed that NP-coating did not affect glial reactions or neural cell-count. Coating with NP <10 nm may improve electrode’s impedance stability without affecting biocompatibility. Increased impedance after NP-coating may improve neural recording due to better signal-to-noise ratio.

1 January 2012 in Experimental Neurology
Verified
Journal Article
Closed access
MAMesbah Alam
Mesbah Alam
HHHans E. Heissler
Hans E. Heissler
KSKerstin Schwabe
Kerstin Schwabe
JKJoachim K. Krauss
Joachim K. Krauss

1 January 2014 in Brain Stimulation
Verified
Journal Article
Closed access
MAMesbah Alam
Mesbah Alam
HCH.-H. Capelle
H.-H. Capelle
KSK. Schwabe
K. Schwabe
JKJ.K. Krauss
J.K. Krauss