Guangbin Zhang

Dr. Guangbin Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MZMeiyi Zhu
Meiyi Zhu
WFWei Fan
Wei Fan
GZGuangbin Zhang
Guangbin Zhang
To compare the visual outcomes and subjective experience of three intraocular lenses (IOL) implant strategies. Retrospective comparative study. This study comprised patients who underwent phacoemulsification and bilateral implantation of extended depth of focus (EDOF) IOL (ZXR00; EDOF group), blended implantation of EDOF and bifocal IOL (ZXR00/ZLB00; blended group), and bilateral implantation of trifocal IOL (AT LISA tri 839MP; trifocal group). The outcomes included visual acuity (VA), visual defocus curve, contrast sensitivity, visual quality, quality of life, spectacle independence, and patient satisfaction. Follow-up was performed 3 months after the surgery. This study included 114 eyes of 57 patients (20 in EDOF group; 16 in blended group; 21 in trifocal group). Patients in the three groups had high quality of life, patient satisfaction, and good contrast sensitivity. The EDOF group had the worst near VA, but the visual quality was the best. The blended group had good VA and slight photic disturbance. The trifocal group obtained the best whole range of VA, but the photic disturbance was significantly severe than the EDOF group. Both the blended and trifocal groups achieved high spectacle independence, but some patients in the EDOF group need spectacle when dealing with close-range tasks.

5 August 2024 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
ZZZongsheng Zeng
Zongsheng Zeng
MZMeiyi Zhu
Meiyi Zhu
GZGuangbin Zhang
Guangbin Zhang
To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.

21 May 2025 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
WFWei Fan
Wei Fan
MZMeiyi Zhu
Meiyi Zhu
GZGuangbin Zhang
Guangbin Zhang
Purpose: To compare visual outcomes, depth of field (DOF), spectacle independence, and patient satisfaction of cataract patients with and without previous myopic laser in situ keratomileusis (LASIK) surgery who received a non-diffractive extended range-of-focus (EROF) intraocular lens (IOL).Setting: Xiamen Eye Center, Xiamen, China.Design: Prospective case series.Methods: A total of 50 eyes of 41 patients implanted with the Vivity IOL were divided into Post-LASIK and Virgin groups. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), refractive outcomes, defocus curves, subjective DOF, spectacle independence, and Visual Function questionnaire (VF-14) after 3 months postoperatively.Results: Postoperatively, 70% of the Post-LASIK and 86.7% of the Virgin group had refractive error within ± 0.50 D (P = 0.28). The majority of both groups achieved 20/25 or better UDVA, with no significant differences between groups for UDVA, CDVA and UIVA (P > 0.05). The UNVA was significantly better in the Post-LASIK group (0.31 ± 0.08 logMAR) than Virgin group (0.45 ± 0.10 logMAR, P < 0.001). The Post-LASIK group showed a smoother curve with a wider landing area, and better subjective DOF compared to the Virgin group (P < 0.001). Spectacle independence at near ranges in bright light was higher in the Post-LASIK group (81.3 % vs 48 %, P = 0.033). Both groups reported high visual satisfaction, but the Post-LASIK group had fewer difficulties with near-distance tasks in the VF-14 questionnaire.Conclusion: In post-LASIK eyes, this wavefront-shaping EROF IOL was well-tolerated and provided an extended range of vision with significantly better UNVA, fewer difficulties in daily activities and higher spectacle independence for near vision compared to normal eyes.

1 January 2021 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
QCQingzhong Chen
Qingzhong Chen
GZGuangbin Zhang
Guangbin Zhang

10 July 2023 in Advances in Ophthalmology Practice and Research
Verified
Journal Article
Open access
WFWei Fan
Wei Fan
GZGuangbin Zhang
Guangbin Zhang
Purpose: To evaluate near, intermediate, distance visual acuity and stereopsis after bilateral implantation of Toric intraocular lenses (IOLs) in high myopic patients with astigmatism. Methods: Bilateral Toric or non-Toric IOL implantation (n = 40 eyes each) was performed on high myopic cataract eyes with astigmatism. Best-corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), residual refractive astigmatism (RRA), and near, intermediate, and distance stereoacuity were measured postoperatively at 7 days, 1 month, and 3 months. Results: The three-month postoperative BCDVA, UCIVA, and UCNVA of the Toric group were 0.08 f 0.07, 0.30 f 0.11, and 0.23 f 0.14 LogMAR. All improved over the preoperative assessments (P P < 0.05). The RRA, UCIVA, and UCNVA were significantly better in the Toric group than the non-Toric group at all follow-up examinations (all P < 0.05). At 3 months, the median near and intermediate stereoacuity of the Toric group were 100 (range 40 - 400) and 120 (range 50 - 400) arcsec, which were better than the non-Toric group (both P < 0.05). Fine near stereopsis >= 100 arcsec was present in 65% of the Toric patients, and 50% had good intermediate stereopsis of >= 100 arcsec. However among non-Toric patients, only 15% and 5% achieved fine near and intermediate stereopsis. The postoperative BCDVA and best-corrected distance stereoacuity were similar in the two groups (P P > 0.05). Conclusions: In bilateral high myopic cataract patients with astigmatism, Toric IOLs not only improved UCIVA, UCNVA, and RRA, but also enhanced near and intermediate stereopsis acuity.

1 January 2024 in Journal of Ophthalmology
Verified
Journal Article
Open access
QCQingzhong Chen
Qingzhong Chen
GZGuangbin Zhang
Guangbin Zhang
Purpose: To compare the standard outcomes between the PanOptix and Symfony multifocal intraocular lenses (MIOLs) in Chinese patients.Methods: This prospective observational cohort study enrolled patients with cataracts between April 2021 and December 2021 at Xiamen Eye Center Affiliated to Xiamen University. The patients were grouped in the PanOptix (TIOL group) and Symfony (EDF group) according to the IOLs implanted. Uncorrected distant, corrected distance, binocular uncorrected intermediate, and near visual acuity (UNVA), distance‐corrected intermediate and near VA (DCNVA) , defocus curve, spectacle independence, contrast sensitivity (CS), and visual disturbances were evaluated after 3 months.Results: Forty patients (80 eyes) were enrolled in the study (20/group). Three months after the operation, UNVA (0.13 ± 0.16) and DCNVA (0.08 ± 0.08) were better in the TIOL group than in the EDF group (0.22 ± 0.08 and 0.22 ± 0.08, respectively, p = 0.003 and p < 0.001, respectively). The TIOL group achieved a better‐than‐0.15‐logMAR VA from +0.5 D to −2.5 D (40 cm). VAs of the TIOL group from −1 D (100 cm) to −4 D (25 cm) were better than in the EDF group (p < 0.05). There were no significant differences in the intermediate and far vision outcomes (p > 0.05). Total near‐vision spectacle independence was higher in the TIOL group (80%) than in the EDF group (50%) (p = 0.039).Conclusion: Compared with EDF, TIOL leads to better near‐vision outcomes without significant differences for intermediate and distant vision outcomes.Trial Registration: ClinicalTrials.gov identifier: ChiCTR2100044558.