GIOVANNI NICO

Dr. GIOVANNI NICO

Istituto Per Le Applicazioni Del Calcolo Mauro Picone, Rome, Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2019 in Remote Sensing
Verified
Journal Article
Open access
PDF file
PBPedro Benevides
Pedro Benevides
Joao CatalaoJoao Catalao
Joao Catalao
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
This work presents a methodology for the short-term forecast of intense rainfall based on a neural network and the integration of Global Navigation and Positioning System (GNSS) and meteorological data. Precipitable water vapor (PWV) derived from GNSS is combined with surface pressure, surface temperature and relative humidity obtained continuously from a ground-based meteorological station. Five years of GNSS data from one station in Lisbon, Portugal, are processed. Data for precipitation forecast are also collected from the meteorological station. Spaceborne Spinning Enhanced Visible and Infrared Imager (SEVIRI) data of cloud top measurements are also gathered, providing collocated information on an hourly basis. In previous studies it was found that the time-varying PWV is correlated with rainfall and can be used to detected heavy rain. However, a significant number of false positives were found, meaning that the evolution of PWV does not contain enough information to infer future rain. In this work, a nonlinear autoregressive exogenous neural network model (NARX) is used to process the GNSS and meteorological data to forecast the hourly precipitation. The proposed methodology improves the detection of intense rainfall events and reduces the number of false positives, with a good classification score varying from 63% up to 72% and a false positive rate of 36% down to 21%, for the tested years in the dataset. A score of 64% for intense rain events classification with 22% false positive rate is obtained for the most recent years. The method also achieves an almost 100% hit rate for the rain vs no rain detection, with close to no false alarms.

7 November 2018 in Journal of Hydrology and Hydromechanics
Verified
Journal Article
Open access
PDF file
VCVasco Conde
Vasco Conde
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
PMPedro Jorge Belé Mateus
Pedro Jorge Belé Mateus
Joao CatalaoJoao Catalao
Joao Catalao
AKAnna Kontu
Anna Kontu
MGMaria Gritsevich
Maria Gritsevich
In this work we present a methodology for the mapping of Snow Water Equivalent (SWE) temporal variations based on the Synthetic Aperture Radar (SAR) Interferometry technique and Sentinel-1 data. The shift in the interferometric phase caused by the refraction of the microwave signal penetrating the snow layer is isolated and exploited to generate maps of temporal variation of SWE from coherent SAR interferograms. The main advantage of the proposed methodology with respect to those based on the inversion of microwave SAR backscattering models is its simplicity and the reduced number of required in-situ SWE measurements. The maps, updated up to every 6 days, can attain a spatial resolution up to 20 m with sub-centimetre ΔSWE measurement accuracy in any weather and sun illumination condition. We present results obtained using the proposed methodology over a study area in Finland. These results are compared with in-situ measurements of ΔSWE, showing a reasonable match with a mean accuracy of about 6 mm.

30 March 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
PMPedro Jorge Belé Mateus
Pedro Jorge Belé Mateus
Joao CatalaoJoao Catalao
Joao Catalao
VMVirgilio Mendes
Virgilio Mendes
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
The Global Navigation Satellite System (GNSS) meteorology contribution to the comprehension of the Earth’s atmosphere’s global and regional variations is essential. In GNSS processing, the zenith wet delay is obtained using the difference between the zenith total delay and the zenith hydrostatic delay. The zenith wet delay can also be converted into precipitable water vapor by knowing the atmospheric weighted mean temperature profiles. Improving the accuracy of the zenith hydrostatic delay and the weighted mean temperature, normally obtained using modeled surface meteorological parameters at coarse scales, leads to a more accurate and precise zenith wet delay estimation, and consequently, to a better precipitable water vapor estimation. In this study, we developed an hourly global pressure and temperature (HGPT) model based on the full spatial and temporal resolution of the new ERA5 reanalysis produced by the European Centre for Medium-Range Weather Forecasts (ECMWF). The HGPT model provides information regarding the surface pressure, surface air temperature, zenith hydrostatic delay, and weighted mean temperature. It is based on the time-segmentation concept and uses the annual and semi-annual periodicities for surface pressure, and annual, semi-annual, and quarterly periodicities for surface air temperature. The amplitudes and initial phase variations are estimated as a periodic function. The weighted mean temperature is determined using a 20-year time series of monthly data to understand its seasonality and geographic variability. We also introduced a linear trend to account for a global climate change scenario. Data from the year 2018 acquired from 510 radiosonde stations downloaded from the National Oceanic and Atmospheric Administration (NOAA) Integrated Global Radiosonde Archive were used to assess the model coefficients. Results show that the GNSS meteorology, hydrological models, Interferometric Synthetic Aperture Radar (InSAR) meteorology, climate studies, and other topics can significantly benefit from an ERA5 full-resolution model.

16 January 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Joao CatalaoJoao Catalao
Joao Catalao
DRDurairaju Raju
Durairaju Raju
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
Global mean sea level rise associated with global warming has a major impact on coastal areas and represents one of the significant natural hazards. The Asia-Pacific region, which has the highest concentration of human population in the world, represents one of the larger areas on Earth being threatened by the rise of sea level. Recent studies indicate a global sea level of 3.2 mm/yr as measured from 20 years of satellite altimetry. The combined effect of sea level rise and local land subsidence, can be overwhelming for coastal areas. The Synthetic Aperture Radar (SAR) interferometry technique is used to process a time series of TerraSAR-X images and estimate the land subsidence in the urban area of Singapore. Interferometric SAR (InSAR) measurements are merged to the Representative Concentration Pathway (RCP) 4.5 and RCP 8.5 sea-level rise scenarios to identify projected inundated areas and provide a map of flood vulnerability. Subsiding rates larger than 5 mm/year are found near the shore on the low flat land, associated to areas recently reclaimed or built. The projected flooded map of Singapore are provided for different sea-level rise scenarios. In this study, we show that local land subsidence can increase the flood vulnerability caused by sea level rise by 2100 projections. This can represent an increase of 25% in the flood area in the central area of Singapore for the RCP4.5 scenario.

25 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SASerena Artese
Serena Artese
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
This article presents a methodology for the monitoring of tall structures based on the joint use of a terrestrial laser scanner (TLS), configured in line scanner mode, and a ground-based real aperture radar (GB-RAR) interferometer. The methodology provides both natural frequencies and oscillation amplitudes of tall structures. Acquisitions of the surface of the tall structure are performed by the TLS with a high sampling rate: each line scan provides an instantaneous longitudinal section. By interpolating the points of each line, oscillation profiles are estimated with a much better precision than each single point. The amplitude and frequency of the main oscillation mode of the whole structure are derived from the TLS profiles. GB-RAR measurements are used to measure the vibration frequencies of higher oscillation modes which are not caught by the TLS due its lower precision in the measurement of displacements. In contrast, the high spatial resolution of TLS measurements provides an accurate description of oscillation amplitude along the tower, which cannot be caught by the GB-RAR, due to its poorer spatial resolution. TLS and GB-RAR acquisitions are simultaneous. The comparison with the analytical solution for oscillation modes demonstrates that the proposed methodology can provide useful information for structural health monitoring (SHM). The methodology does not require the use of targets on the structure and it can be applied during its normal use, even in presence of dynamic loads (wind, traffic vibrations, etc.). A test was carried out on a wind tower where the synergistic use of TLS and GB-RAR made it possible to fully describe the spectral properties of the tower and at the same time measure the amplitude of the first oscillation mode along the tower with a high spatial resolution.

16 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
APAndrea Di Pasquale
Andrea Di Pasquale
GIOVANNI NICOGIOVANNI NICO
GIOVANNI NICO
APAlfredo Pitullo
Alfredo Pitullo
Giuseppina PreziosoGiuseppina Prezioso
Giuseppina Prezioso
The aim of this paper is to describe how ground-based radar interferometry can provide displacement measurements of earth dam surfaces and of vibration frequencies of its main concrete infrastructures. In many cases, dams were built many decades ago and, at that time, were not equipped with in situ sensors embedded in the structure when they were built. Earth dams have scattering properties similar to landslides for which the Ground-Based Synthetic Aperture Radar (GBSAR) technique has been so far extensively applied to study ground displacements. In this work, SAR and Real Aperture Radar (RAR) configurations are used for the measurement of earth dam surface displacements and vibration frequencies of concrete structures, respectively. A methodology for the acquisition of SAR data and the rendering of results is described. The geometrical correction factor, needed to transform the Line-of-Sight (LoS) displacement measurements of GBSAR into an estimate of the horizontal displacement vector of the dam surface, is derived. Furthermore, a methodology for the acquisition of RAR data and the representation of displacement temporal profiles and vibration frequency spectra of dam concrete structures is presented. For this study a Ku-band ground-based radar, equipped with horn antennas having different radiation patterns, has been used. Four case studies, using different radar acquisition strategies specifically developed for the monitoring of earth dams, are examined. The results of this work show the information that a Ku-band ground-based radar can provide to structural engineers for a non-destructive seismic assessment of earth dams.