Payam Razavi

Payam Razavi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HTHaimi Tang
Haimi Tang
PRPayam Razavi
Payam Razavi
KPKoohyar Pooladvand
Koohyar Pooladvand
PPPavel Psota
Pavel Psota
NMNima Maftoon
Nima Maftoon
Jeffrey ChengJeffrey Cheng
Jeffrey Cheng
To improve the understanding of the middle-ear hearing mechanism and assist in the diagnosis of middle-ear diseases, we are developing a high-speed digital holographic (HDH) system to measure the shape and acoustically-induced transient displacements of the tympanic membrane (TM). In this paper, we performed measurements on cadaveric human ears with simulated common middle-ear pathologies. The frequency response function (FRF) of the normalized displacement by the stimulus (sound pressure) at each measured pixel point of the entire TM surface was calculated and the complex modal indicator function (CMIF) of the middle-ear system based on FRFs of the entire TM surface motions was used to differentiate different middle-ear pathologies. We also observed changes in the TM shape and the surface motion pattern before and after various middle-ear manipulations. The observations of distinguishable TM shapes and motion patterns in both time and frequency domains between normal and experimentally simulated pathological ears support the development of a quantitative clinical holography-based apparatus for diagnosing middle-ear pathologies.

25 September 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PRPayam Razavi
Payam Razavi
HTHaimi Tang
Haimi Tang
JRJohn J. Rosowski
John J. Rosowski
CFCosme Furlong
Cosme Furlong
JCJeffrey T. Cheng
Jeffrey T. Cheng
The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-μs impulse) and the shape are consecutively measured within 2 kHz) optical phase sampling during a single 100-ms wavelength tuning ramp allow precise and rapid reconstructions of the TM shape at varied resolutions (50 to 200 μm). This rapid acquisition of full-field displacements and shape is immune to slow disturbances introduced by breathing or heartbeat of live subjects. Knowledge of TM shape and displacements enables the estimation of surface normal displacements regardless of the orientation of the TM within the measurement system. The proposed method helps better define TM mechanics and provides TM structure and function information useful for the diagnosis of ear disease.

27 March 2018
Verified
Conference Paper
Closed access
GFGabrielle Franzini
Gabrielle Franzini
CGCharles Gentile
Charles Gentile
CFCosme Furlong
Cosme Furlong
PRPayam Razavi
Payam Razavi
RHRobert Hitchner
Robert Hitchner
DMDarold Martin
Darold Martin

21 September 2016
Verified
Book Chapter
Closed access
PDF file
PRPayam Razavi
Payam Razavi
JCJeffrey Tao Cheng
Jeffrey Tao Cheng
CFCosme Furlong
Cosme Furlong
JRJohn J. Rosowski
John J. Rosowski

12 October 2018
Verified
Book Chapter
Closed access
PDF file
PRPayam Razavi
Payam Razavi
HTHaimi Tang
Haimi Tang
NMNima Maftoon
Nima Maftoon
JRJohn J. Rosowski
John J. Rosowski
CFCosme Furlong
Cosme Furlong
JCJeffrey Tao Cheng
Jeffrey Tao Cheng

1 January 2016
Verified
Book Chapter
Closed access
PDF file
PRPayam Razavi
Payam Razavi
IDIvo Dobrev
Ivo Dobrev
MRMichael E. Ravicz
Michael E. Ravicz
JCJeffery Tao Cheng
Jeffery Tao Cheng
CFCosme Furlong
Cosme Furlong
JRJohn J. Rosowski
John J. Rosowski